* Copyright (c) 2018 Martin Jäger / Libre Solar
*
* SPDX-License-Identifier: Apache-2.0
*/
#include "tests.h"
#include <time.h>
#include <stdio.h>
#include <math.h>
#include "main.h"
void reset_counters_at_start_of_day()
{
solar_terminal.voltage = bat_terminal.voltage - 1;
dev_stat.day_counter = 0;
solar_terminal.neg_energy_Wh = 10.0;
bat_terminal.neg_energy_Wh = 3.0;
bat_terminal.pos_energy_Wh = 4.0;
load_terminal.pos_energy_Wh = 9.0;
// 5 houurs without sun
for (int i = 0; i <= 5 * 60 * 60; i++) {
dev_stat.update_energy();
}
TEST_ASSERT_EQUAL(10, dev_stat.solar_in_total_Wh);
TEST_ASSERT_EQUAL(3, dev_stat.bat_dis_total_Wh);
TEST_ASSERT_EQUAL(4, dev_stat.bat_chg_total_Wh);
TEST_ASSERT_EQUAL(9, dev_stat.load_out_total_Wh);
TEST_ASSERT_EQUAL(10, solar_terminal.neg_energy_Wh);
TEST_ASSERT_EQUAL(3, bat_terminal.neg_energy_Wh);
TEST_ASSERT_EQUAL(4, bat_terminal.pos_energy_Wh);
TEST_ASSERT_EQUAL(9, load_terminal.pos_energy_Wh);
// solar didn't come back yet
TEST_ASSERT_EQUAL(0, dev_stat.day_counter);
// now solar power comes back
solar_terminal.voltage = bat_terminal.voltage + 1;
dev_stat.update_energy();
// day counter should be increased and daily energy counters reset
TEST_ASSERT_EQUAL(1, dev_stat.day_counter);
TEST_ASSERT_EQUAL(0, solar_terminal.neg_energy_Wh);
TEST_ASSERT_EQUAL(0, bat_terminal.neg_energy_Wh);
TEST_ASSERT_EQUAL(0, bat_terminal.pos_energy_Wh);
TEST_ASSERT_EQUAL(0, load_terminal.pos_energy_Wh);
}
void dev_stat_new_solar_voltage_max()
{
solar_terminal.voltage = 40;
dev_stat.update_min_max_values();
TEST_ASSERT_EQUAL(40, dev_stat.solar_voltage_max);
}
void dev_stat_new_bat_voltage_max()
{
bat_terminal.voltage = 31;
dev_stat.update_min_max_values();
TEST_ASSERT_EQUAL(31, dev_stat.battery_voltage_max);
}
void dev_stat_new_dcdc_current_max()
{
dcdc.lvs->current = 21;
dev_stat.update_min_max_values();
TEST_ASSERT_EQUAL(21, dev_stat.dcdc_current_max);
}
void dev_stat_new_load_current_max()
{
load.port->current = 21;
dev_stat.update_min_max_values();
TEST_ASSERT_EQUAL(21, dev_stat.load_current_max);
}
void dev_stat_solar_power_max()
{
solar_terminal.power = -50;
dev_stat.update_min_max_values();
TEST_ASSERT_EQUAL(50, dev_stat.solar_power_max_day);
TEST_ASSERT_EQUAL(50, dev_stat.solar_power_max_total);
}
void dev_stat_load_power_max()
{
load.port->power = 50;
dev_stat.update_min_max_values();
TEST_ASSERT_EQUAL(50, dev_stat.load_power_max_day);
TEST_ASSERT_EQUAL(50, dev_stat.load_power_max_total);
}
void dev_stat_new_mosfet_temp_max()
{
dcdc.temp_mosfets = 80;
dev_stat.update_min_max_values();
TEST_ASSERT_EQUAL(80, dev_stat.mosfet_temp_max);
}
void dev_stat_new_bat_temp_max()
{
charger.bat_temperature = 45;
dev_stat.update_min_max_values();
TEST_ASSERT_EQUAL(45, dev_stat.bat_temp_max);
}
void dev_stat_new_int_temp_max()
{
dev_stat.int_temp_max = 20;
dev_stat.internal_temp = 22;
dev_stat.update_min_max_values();
TEST_ASSERT_EQUAL(22, dev_stat.int_temp_max);
}
void device_status_tests()
{
UNITY_BEGIN();
RUN_TEST(reset_counters_at_start_of_day);
RUN_TEST(dev_stat_new_solar_voltage_max);
RUN_TEST(dev_stat_new_bat_voltage_max);
RUN_TEST(dev_stat_new_dcdc_current_max);
RUN_TEST(dev_stat_new_load_current_max);
RUN_TEST(dev_stat_solar_power_max);
RUN_TEST(dev_stat_load_power_max);
RUN_TEST(dev_stat_new_mosfet_temp_max);
RUN_TEST(dev_stat_new_bat_temp_max);
RUN_TEST(dev_stat_new_int_temp_max);
UNITY_END();
}