Previous naming with chg/dis didn't make much sense e.g. for load output or solar panels. Voltage
targets are now named with source or sink. Current limits are defined based on their direction
(negative or positive). ASCII art graphic added for better explanation of passive sign convention.
Reason: Previous idea with storing the voltage only once and not in every port
doesn't work well for droop settings, e.g. the DC/DC output port doesn't know
the actual battery current, which should be used to calculate the droop caued
by wire resistance.
- Solar and battery ports now defined as references to actual hardware ports at very beginning of main.cpp, allowing to use the references also in data_objects.cpp
- Different charger types (PWM / MPPT) are configured more clearly by switching on/off features (DC/DC, PWM switch and load) in PCB configuration
The DC bus type caused issues because current limits could not be defined individually for each
connection to a junction, as described in issue #50.
With this commit, also some structs were converted to C++ classes to improve readibility of the
code and make sure that pointers (e.g. to PowerPort objects) are always assigned during
initialization.
- Discharging control separated from charger state machine
- Unit-tests for discharging control added
- DC bus chg/dis_enabled flags removed, control now only based on chge/dis_current_limit values
- _current_max values renamed to _limit to make more clear that values for discharging direction must be negative
- Load output struct now stores pointer to internal and external DC bus objects
- DcBus representing actual screw terminals renamed
- Internal DC bus at DC/DC low voltage side added for correct DC/DC control
- DC/DC struct now stores pointers to HV and LV bus objects. Redundant voltage and current measurement variables removed.
- Unit tests updated
DC/DC control needs further improvements to make use of the changes
- Serious bug: Switch did not go below 90% duty cycle (left-over from testing code). Could result in overcharging of battery.
- Improvement: Preventing very short on/off times (duty cycles close to 0 or 1) as switching time is quite slow
- PWM frequency now configurable via PCB config (and increased from 20 to 25 Hz)
- Some unused parameters in PwmSwitch struct removed and variables renamed
- Overcurrent setting now via solar_bus
This way the OLED display does not overwrite useful data since
the stack on the F072RB in mbed is just 1k and the logog is also 1k.
Also fixed minor issue in OLED display code (refactoring not done).
- Battery temperature set to 25 degC if no external sensor connected
- EEPROM selection added to PCB config file
- UEXT power supply enable added to UEXT init functions
Firmware still gets stuck when OLED display is enabled... Error still to be found!
- Correct negative sign for incoming solar current
- Current multiplied with PWM duty cycle to get average current
- Min/max calculation moved to log.cpp
- Using PlatformIO's embedded unit testing with native environment
- mbed-dependent .cpp files escaped with #ifndef UNIT_TEST
- First tests for charger module added under test/ directory
- Files for interfaces connected via UEXT are stored in separate uext/ directory
- UEXT init and process function names independent of connected module
- LED function names adjusted to start with leds_
- main.cpp structure simplified