Cleanup of comments in bat_charger.h
This commit is contained in:
+178
-67
@@ -35,87 +35,102 @@ enum BatType {
|
||||
BAT_TYPE_NMC_HV ///< NMC/Graphite High Voltage Li-ion batteries (3.7V nominal, 4.35 max)
|
||||
};
|
||||
|
||||
/** Battery configuration data
|
||||
/**
|
||||
* Battery configuration data
|
||||
*
|
||||
* Data will be initialized in battery_init depending on configured cell type in config.h.
|
||||
*/
|
||||
typedef struct
|
||||
{
|
||||
/** Nominal battery capacity or sum of parallel cells capacity (Ah)
|
||||
/**
|
||||
* Nominal battery capacity or sum of parallel cells capacity (Ah)
|
||||
*
|
||||
* The nominal capacity is used for SOC calculation and definition of current limits.
|
||||
*/
|
||||
float nominal_capacity;
|
||||
|
||||
/** Recharge voltage (V)
|
||||
/**
|
||||
* Recharge voltage (V)
|
||||
*
|
||||
* Start charging again if voltage of fully charged battery drops below this threshold.
|
||||
*
|
||||
* Remark: Setting the value too close to the max voltage will cause more charging stress on lithium based batteries.
|
||||
* Remark: Setting the value too close to the max voltage will cause more charging stress on
|
||||
* lithium based batteries.
|
||||
*/
|
||||
float voltage_recharge;
|
||||
|
||||
/** Recharge time limit (sec)
|
||||
/**
|
||||
* Recharge time limit (sec)
|
||||
*
|
||||
* Start charging of previously fully charged battery earliest after this period of time.
|
||||
*/
|
||||
int32_t time_limit_recharge;
|
||||
|
||||
/** Absolute maximum voltage (V)
|
||||
/**
|
||||
* Absolute maximum voltage (V)
|
||||
*
|
||||
* Above this voltage the battery or loads might get damaged.
|
||||
*/
|
||||
float voltage_absolute_max;
|
||||
|
||||
/** Absolute minimum voltage (V)
|
||||
/**
|
||||
* Absolute minimum voltage (V)
|
||||
*
|
||||
* Below this voltage the battery is considered damaged.
|
||||
*/
|
||||
float voltage_absolute_min;
|
||||
|
||||
/** Maximum charge current in *CC/bulk* phase (A)
|
||||
/**
|
||||
* Maximum charge current in *CC/bulk* phase (A)
|
||||
*
|
||||
* Limits the current if the PCB allows more than the battery. (positive value)
|
||||
*/
|
||||
float charge_current_max;
|
||||
|
||||
/** Maximum discharge current via load port (A)
|
||||
/**
|
||||
* Maximum discharge current via load port (A)
|
||||
*
|
||||
* Limits the current if the PCB allows more than the battery. (positive value)
|
||||
*/
|
||||
float discharge_current_max;
|
||||
|
||||
/** Maximum voltage in CV/absorption phase (V)
|
||||
/**
|
||||
* Maximum voltage in CV/absorption phase (V)
|
||||
*
|
||||
* Charger target voltage, switching from CC to CV at this voltage threshold.
|
||||
*/
|
||||
float topping_voltage;
|
||||
|
||||
/** CV phase cut-off current limit (A)
|
||||
/**
|
||||
* CV phase cut-off current limit (A)
|
||||
*
|
||||
* Constant voltage charging phase stopped if current is below this value.
|
||||
*/
|
||||
float topping_current_cutoff;
|
||||
|
||||
/** CV phase cut-off time limit (s)
|
||||
/**
|
||||
* CV phase cut-off time limit (s)
|
||||
*
|
||||
* After this time, CV charging is stopped independent of current.
|
||||
*/
|
||||
int32_t topping_duration;
|
||||
|
||||
/** Enable float/trickle charging
|
||||
/**
|
||||
* Enable float/trickle charging
|
||||
*
|
||||
* Caution: Do not enable trickle charging for lithium-ion batteries
|
||||
*/
|
||||
bool trickle_enabled;
|
||||
|
||||
/** Trickle voltage (V)
|
||||
/**
|
||||
* Trickle voltage (V)
|
||||
*
|
||||
* Charger target voltage for trickle charging of lead-acid batteries
|
||||
*/
|
||||
float trickle_voltage;
|
||||
|
||||
/** Trickle recharge time (s)
|
||||
/**
|
||||
* Trickle recharge time (s)
|
||||
*
|
||||
* If the trickle voltage is not reached anymore (e.g. because of lack of solar
|
||||
* input power) for this period of time, the charger state machine goes back
|
||||
@@ -123,43 +138,50 @@ typedef struct
|
||||
*/
|
||||
int32_t trickle_recharge_time;
|
||||
|
||||
/** Enable equalization charging
|
||||
/**
|
||||
* Enable equalization charging
|
||||
*
|
||||
* Caution: Do not enable trickle charging for lithium-ion batteries
|
||||
*/
|
||||
bool equalization_enabled;
|
||||
|
||||
/** Equalization voltage (V)
|
||||
/**
|
||||
* Equalization voltage (V)
|
||||
*
|
||||
* Charger target voltage for equalization charging of lead-acid batteries
|
||||
*/
|
||||
float equalization_voltage;
|
||||
|
||||
/** Equalization cut-off time limit (s)
|
||||
/**
|
||||
* Equalization cut-off time limit (s)
|
||||
*
|
||||
* After this time, equalization charging is stopped.
|
||||
*/
|
||||
int32_t equalization_duration;
|
||||
|
||||
/** Equalization phase maximum current (A)
|
||||
/**
|
||||
* Equalization phase maximum current (A)
|
||||
*
|
||||
* The current of the charger is controlled to stay below this limit during equalization.
|
||||
*/
|
||||
float equalization_current_limit;
|
||||
|
||||
/** Equalization trigger time interval (days)
|
||||
/**
|
||||
* Equalization trigger time interval (days)
|
||||
*
|
||||
* After passing specified amount of days, an equalization charge is triggered.
|
||||
*/
|
||||
int32_t equalization_trigger_days;
|
||||
|
||||
/** Equalization trigger deep-discharge cycles
|
||||
/**
|
||||
* Equalization trigger deep-discharge cycles
|
||||
*
|
||||
* After specified number of deep discharges, an equalization charge is triggered.
|
||||
*/
|
||||
int32_t equalization_trigger_deep_cycles;
|
||||
|
||||
/** Load disconnect open circuit voltage (V)
|
||||
/**
|
||||
* Load disconnect open circuit voltage (V)
|
||||
*
|
||||
* Load output is disabled if battery voltage is below this threshold.
|
||||
*
|
||||
@@ -170,7 +192,8 @@ typedef struct
|
||||
*/
|
||||
float voltage_load_disconnect;
|
||||
|
||||
/** Load reconnect open circuit voltage (V)
|
||||
/**
|
||||
* Load reconnect open circuit voltage (V)
|
||||
*
|
||||
* Re-enable the load only after charged beyond this value.
|
||||
*
|
||||
@@ -181,43 +204,62 @@ typedef struct
|
||||
*/
|
||||
float voltage_load_reconnect;
|
||||
|
||||
/** Battery internal resistance (Ohm)
|
||||
/**
|
||||
* Battery internal resistance (Ohm)
|
||||
*
|
||||
* Resistance value for current-compensation of load switch voltage thresholds.
|
||||
*
|
||||
* The value must have a positive sign. Only resistance values leading to less than 10% voltage drop at max. current are allowed.
|
||||
* The value must have a positive sign. Only resistance values leading to less than 10% voltage
|
||||
* drop at max. current are allowed.
|
||||
*/
|
||||
float internal_resistance;
|
||||
|
||||
/** Resistance of wire between charge controller and battery (Ohm)
|
||||
/**
|
||||
* Resistance of wire between charge controller and battery (Ohm)
|
||||
*
|
||||
* Resistance value for current-compensation of charging voltages.
|
||||
*
|
||||
* The value must have a positive sign. Only resistance values leading to less than 3% voltage loss at max. current are allowed.
|
||||
* The value must have a positive sign. Only resistance values leading to less than 3% voltage
|
||||
* loss at max. current are allowed.
|
||||
*/
|
||||
float wire_resistance;
|
||||
|
||||
// used to calculate state of charge information
|
||||
/**
|
||||
* Open circuit voltage of full battery (V)
|
||||
*
|
||||
* Used for simple state of charge (SOC) algorithm.
|
||||
*/
|
||||
float ocv_full;
|
||||
|
||||
/**
|
||||
* Open circuit voltage of empty battery (V)
|
||||
*
|
||||
* Used for simple state of charge (SOC) algorithm.
|
||||
*/
|
||||
float ocv_empty;
|
||||
|
||||
/** Maximum allowed charging temperature of the battery (°C)
|
||||
/**
|
||||
* Maximum allowed charging temperature of the battery (°C)
|
||||
*/
|
||||
float charge_temp_max;
|
||||
|
||||
/** Minimum allowed charging temperature of the battery (°C)
|
||||
/**
|
||||
* Minimum allowed charging temperature of the battery (°C)
|
||||
*/
|
||||
float charge_temp_min;
|
||||
|
||||
/** Maximum allowed discharging temperature of the battery (°C)
|
||||
/**
|
||||
* Maximum allowed discharging temperature of the battery (°C)
|
||||
*/
|
||||
float discharge_temp_max;
|
||||
|
||||
/** Minimum allowed discharging temperature of the battery (°C)
|
||||
/**
|
||||
* Minimum allowed discharging temperature of the battery (°C)
|
||||
*/
|
||||
float discharge_temp_min;
|
||||
|
||||
/** Voltage compensation based on battery temperature (mV/K/cell)
|
||||
/**
|
||||
* Voltage compensation based on battery temperature (mV/K/cell)
|
||||
*
|
||||
* Suggested value: -3 mV/K/cell
|
||||
*/
|
||||
@@ -225,7 +267,8 @@ typedef struct
|
||||
|
||||
} BatConf;
|
||||
|
||||
/** Charger configuration and battery state
|
||||
/**
|
||||
* Charger configuration and battery state
|
||||
*/
|
||||
class Charger
|
||||
{
|
||||
@@ -235,53 +278,111 @@ public:
|
||||
|
||||
PowerPort *port;
|
||||
|
||||
uint32_t state; ///< Current charger state (see enum ChargerState)
|
||||
/**
|
||||
* Current charger state (see enum ChargerState)
|
||||
*/
|
||||
uint32_t state;
|
||||
|
||||
float bat_temperature = 25; ///< Battery temperature in °C from ext. temperature sensor
|
||||
///< (if existing)
|
||||
bool ext_temp_sensor; ///< True if external temperature sensor was detected
|
||||
/**
|
||||
* Battery temperature (°C) from ext. temperature sensor (if existing)
|
||||
*/
|
||||
float bat_temperature = 25;
|
||||
|
||||
float usable_capacity; ///< Estimated usable capacity (Ah) based on coulomb counting
|
||||
/**
|
||||
* Flag to indicate if external temperature sensor was detected
|
||||
*/
|
||||
bool ext_temp_sensor;
|
||||
|
||||
float discharged_Ah; ///< Coulomb counter for SOH calculation
|
||||
/**
|
||||
* Estimated usable capacity (Ah) based on coulomb counting
|
||||
*/
|
||||
float usable_capacity;
|
||||
|
||||
uint16_t num_full_charges; ///< Number of full charge cycles
|
||||
uint16_t num_deep_discharges; ///< Number of deep-discharge cycles
|
||||
/**
|
||||
* Coulomb counter for SOH calculation
|
||||
*/
|
||||
float discharged_Ah;
|
||||
|
||||
uint16_t soc = 100; ///< State of Charge (%)
|
||||
uint16_t soh = 100; ///< State of Health (%)
|
||||
/**
|
||||
* Number of full charge cycles
|
||||
*/
|
||||
uint16_t num_full_charges;
|
||||
|
||||
time_t time_state_changed; ///< Timestamp of last state change
|
||||
time_t time_target_voltage_reached; ///< Last time the CV limit was reached
|
||||
/**
|
||||
* Number of deep-discharge cycles
|
||||
*/
|
||||
uint16_t num_deep_discharges;
|
||||
|
||||
int target_voltage_timer; ///< Counts the number of seconds during which the target
|
||||
///< voltage of current charging phase was reached.
|
||||
/**
|
||||
* State of Charge (%)
|
||||
*/
|
||||
uint16_t soc = 100;
|
||||
|
||||
time_t time_last_equalization; ///< Timestamp after finish of last equalization charge
|
||||
int deep_dis_last_equalization; ///< Deep discharge counter value after last equalization
|
||||
/**
|
||||
* State of Health (%)
|
||||
*/
|
||||
uint16_t soh = 100;
|
||||
|
||||
bool full; ///< Flag to indicate if battery was fully charged
|
||||
bool empty; ///< Flag to indicate if battery was completely discharged
|
||||
/**
|
||||
* Timestamp of last state change
|
||||
*/
|
||||
time_t time_state_changed;
|
||||
|
||||
/** Detect if two batteries are connected in series (12V/24V auto-detection)
|
||||
/**
|
||||
* Last time the CV limit was reached
|
||||
*/
|
||||
time_t time_target_voltage_reached;
|
||||
|
||||
/**
|
||||
* Counts the number of seconds during which the target voltage of current charging phase was
|
||||
* reached.
|
||||
*/
|
||||
int target_voltage_timer;
|
||||
|
||||
/**
|
||||
* Timestamp after finish of last equalization charge
|
||||
*/
|
||||
time_t time_last_equalization;
|
||||
|
||||
/**
|
||||
* Deep discharge counter value after last equalization
|
||||
*/
|
||||
int deep_dis_last_equalization;
|
||||
|
||||
/**
|
||||
* Flag to indicate if battery was fully charged
|
||||
*/
|
||||
bool full;
|
||||
|
||||
/**
|
||||
* Flag to indicate if battery was completely discharged
|
||||
*/
|
||||
bool empty;
|
||||
|
||||
/**
|
||||
* Detect if two batteries are connected in series (12V/24V auto-detection)
|
||||
*/
|
||||
void detect_num_batteries(BatConf *bat);
|
||||
|
||||
/** Discharging control update (for load output), should be called once per second
|
||||
/**
|
||||
* Discharging control update (for load output), should be called once per second
|
||||
*/
|
||||
void discharge_control(BatConf *bat_conf);
|
||||
|
||||
/** Charger state machine update, should be called once per second
|
||||
/**
|
||||
* Charger state machine update, should be called once per second
|
||||
*/
|
||||
void charge_control(BatConf *bat_conf);
|
||||
|
||||
/** SOC estimation
|
||||
/**
|
||||
* SOC estimation
|
||||
*
|
||||
* Must be called exactly once per second, otherwise SOC calculation gets wrong.
|
||||
*/
|
||||
void update_soc(BatConf *bat_conf);
|
||||
|
||||
/** Initialize terminal and dc bus for battery connection
|
||||
/**
|
||||
* Initialize terminal and dc bus for battery connection
|
||||
*
|
||||
* @param bat Configuration to be used for terminal setpoints
|
||||
*/
|
||||
@@ -292,7 +393,8 @@ private:
|
||||
};
|
||||
|
||||
|
||||
/** Possible charger states
|
||||
/**
|
||||
* Possible charger states
|
||||
*
|
||||
* Further information:
|
||||
* - https://en.wikipedia.org/wiki/IUoU_battery_charging
|
||||
@@ -300,21 +402,24 @@ private:
|
||||
*/
|
||||
enum ChargerState {
|
||||
|
||||
/** Idle
|
||||
/**
|
||||
* Idle
|
||||
*
|
||||
* Initial state of the charge controller. If the solar voltage is high enough
|
||||
* and the battery is not full, bulk charging mode is started.
|
||||
*/
|
||||
CHG_STATE_IDLE,
|
||||
|
||||
/** Bulk / CC / MPPT charging
|
||||
/**
|
||||
* Bulk / CC / MPPT charging
|
||||
*
|
||||
* The battery is charged with maximum possible current (MPPT algorithm is
|
||||
* active) until the CV voltage limit is reached.
|
||||
*/
|
||||
CHG_STATE_BULK,
|
||||
|
||||
/** Topping / CV / absorption charging
|
||||
/**
|
||||
* Topping / CV / absorption charging
|
||||
*
|
||||
* Lead-acid batteries are charged for some time using a slightly higher charge
|
||||
* voltage. After a current cutoff limit or a time limit is reached, the charger
|
||||
@@ -323,7 +428,8 @@ enum ChargerState {
|
||||
*/
|
||||
CHG_STATE_TOPPING,
|
||||
|
||||
/** Trickle charging
|
||||
/**
|
||||
* Trickle charging
|
||||
*
|
||||
* This mode is kept forever for a lead-acid battery and keeps the battery at
|
||||
* full state of charge. If too much power is drawn from the battery, the
|
||||
@@ -331,7 +437,8 @@ enum ChargerState {
|
||||
*/
|
||||
CHG_STATE_TRICKLE,
|
||||
|
||||
/** Equalization charging
|
||||
/**
|
||||
* Equalization charging
|
||||
*
|
||||
* This mode is only used for lead-acid batteries after several deep-discharge
|
||||
* cycles or a very long period of time with no equalization. Voltage is
|
||||
@@ -342,7 +449,8 @@ enum ChargerState {
|
||||
CHG_STATE_EQUALIZATION
|
||||
};
|
||||
|
||||
/** Basic initialization of battery configuration
|
||||
/**
|
||||
* Basic initialization of battery configuration
|
||||
*
|
||||
* Configures battery based on settings defined in config.h and initializes
|
||||
* bat_user with same values
|
||||
@@ -355,18 +463,21 @@ enum ChargerState {
|
||||
*/
|
||||
void battery_conf_init(BatConf *bat, int type, int num_cells, float nominal_capacity);
|
||||
|
||||
/** Checks battery user settings for plausibility
|
||||
/**
|
||||
* Checks battery user settings for plausibility
|
||||
*/
|
||||
bool battery_conf_check(BatConf *bat);
|
||||
|
||||
/** Overwrites battery settings (config should be checked first)
|
||||
/**
|
||||
* Overwrites battery settings (config should be checked first)
|
||||
*
|
||||
* Settings specified in bat_user will be copied to actual battery_t,
|
||||
* if suggested updates are valid (includes plausibility check!)
|
||||
*/
|
||||
void battery_conf_overwrite(BatConf *source, BatConf *destination, Charger *charger = NULL);
|
||||
|
||||
/** Checks if incoming configuration is different to current configuration
|
||||
/**
|
||||
* Checks if incoming configuration is different to current configuration
|
||||
*
|
||||
* Returns true if changed
|
||||
*/
|
||||
|
||||
Reference in New Issue
Block a user