12A charger config re-enabled and minor improvements
This commit is contained in:
@@ -22,13 +22,14 @@ AnalogValue::AnalogValue(PinName pin, float multiplier, const int num_readings,
|
||||
_adc(pin), _num_readings(num_readings)
|
||||
{
|
||||
_multiplier = multiplier;
|
||||
_offset = 0;
|
||||
update(); // initialize value without filter
|
||||
_filter_constant = filter_constant;
|
||||
}
|
||||
|
||||
void AnalogValue::update()
|
||||
{
|
||||
float tmp = adc_read_avg(_adc, _num_readings) * _vcc * _multiplier;
|
||||
float tmp = adc_read_avg(_adc, _num_readings) * _vcc * _multiplier + _offset;
|
||||
_value = (1.0 - _filter_constant) * tmp + _filter_constant * _value;
|
||||
}
|
||||
|
||||
@@ -51,3 +52,9 @@ void AnalogValue::update_reference_voltage(AnalogIn& adc_ref, float ref_voltage,
|
||||
{
|
||||
_vcc = ref_voltage / adc_read_avg(adc_ref, num_readings);
|
||||
}
|
||||
|
||||
void AnalogValue::calibrate_offset(float expected_value)
|
||||
{
|
||||
float tmp = adc_read_avg(_adc, _num_readings) * _vcc * _multiplier;
|
||||
_offset = expected_value - tmp;
|
||||
}
|
||||
|
||||
@@ -48,6 +48,12 @@ public:
|
||||
*/
|
||||
float read();
|
||||
|
||||
/** Read the last updated (and filtered) ADC result (incl. multiplier)
|
||||
*
|
||||
* @param expected_value Value which should be read under current conditions (after application of multiplier)
|
||||
*/
|
||||
void calibrate_offset(float expected_value = 0.0);
|
||||
|
||||
/** An operator shorthand for read()
|
||||
*
|
||||
* The float() operator can be used as a shorthand for read() to simplify common code sequences
|
||||
@@ -66,7 +72,7 @@ public:
|
||||
}
|
||||
|
||||
private:
|
||||
|
||||
|
||||
/** Read out ADC results and apply averaging and/or low pass filter
|
||||
*
|
||||
* @param input AnalogIn for the pin to be read
|
||||
@@ -85,4 +91,5 @@ private:
|
||||
|
||||
const int _num_readings;
|
||||
float _filter_constant;
|
||||
float _offset;
|
||||
};
|
||||
|
||||
+1
-2
@@ -22,7 +22,6 @@
|
||||
|
||||
#define MPPT_20A
|
||||
|
||||
|
||||
// DC/DC converter settings
|
||||
const int _pwm_frequency = 70; // kHz
|
||||
|
||||
@@ -45,7 +44,7 @@ ChargingProfile profile = {
|
||||
|
||||
// State: CV/absorption
|
||||
2.4, // cell_voltage_max; // max voltage per cell
|
||||
120, // time_limit_CV; // sec
|
||||
120*60, // time_limit_CV; // sec
|
||||
2.0, // current_cutoff_CV; // A
|
||||
|
||||
// State: float/trickle
|
||||
|
||||
+36
-27
@@ -18,46 +18,55 @@
|
||||
#define CONFIG_12A_H
|
||||
|
||||
#include "mbed.h"
|
||||
#include "ChargeController.h"
|
||||
|
||||
#define MPPT_12A
|
||||
|
||||
// DC/DC converter settings
|
||||
const int _pwm_frequency = 100; // kHz
|
||||
|
||||
const int charge_current_cutoff = 20; // mA --> if lower, charger is switched off
|
||||
const int max_solar_voltage = 55000; // mV
|
||||
|
||||
const int num_cells = 6;
|
||||
const float dcdc_current_min = 0.1; // A --> if lower, charger is switched off
|
||||
const float solar_voltage_max = 55.0; // V
|
||||
|
||||
// State: Standby
|
||||
const int solar_voltage_offset_start = 5000; // mV charging switched on if Vsolar > Vbat + offset
|
||||
const int solar_voltage_offset_stop = 1000; // mV charging switched off if Vsolar < Vbat + offset
|
||||
const int time_limit_recharge = 60; // sec
|
||||
const int cell_voltage_recharge = 2300; // mV
|
||||
const float solar_voltage_offset_start = 5.0; // V charging switched on if Vsolar > Vbat + offset
|
||||
const float solar_voltage_offset_stop = 1.0; // V charging switched off if Vsolar < Vbat + offset
|
||||
|
||||
// State: CC/bulk
|
||||
const int charge_current_max = 10000; // mA PCB maximum: 20 A
|
||||
ChargingProfile profile = {
|
||||
6, // num_cells;
|
||||
|
||||
// State: CV/absorption
|
||||
const int cell_voltage_max = 2400; // max voltage per cell
|
||||
const int time_limit_CV = 120; // min
|
||||
const int current_cutoff_CV = 300; //2000; // mA
|
||||
// State: Standby
|
||||
60, // time_limit_recharge; // sec
|
||||
2.3, // cell_voltage_recharge; // V
|
||||
|
||||
// State: float/trickle
|
||||
const bool trickle_enabled = true;
|
||||
const int cell_voltage_trickle = 2300; // voltage for trickle charging of lead-acid batteries
|
||||
const int time_trickle_recharge = 30; // min
|
||||
// State: CC/bulk
|
||||
10.0, // charge_current_max; // A PCB maximum: 20 A
|
||||
|
||||
// State: equalization
|
||||
const bool equalization_enabled = false;
|
||||
const int cell_voltage_equalization = 2500; // mV
|
||||
const int time_limit_equalization = 60; // min
|
||||
const int current_limit_equalization = 1000; // mA
|
||||
const int equalization_trigger_time = 8; // weeks
|
||||
const int equalization_trigger_deep_cycles = 10; // times
|
||||
// State: CV/absorption
|
||||
2.4, // cell_voltage_max; // max voltage per cell
|
||||
120*60, // time_limit_CV; // sec
|
||||
2.0, // current_cutoff_CV; // A
|
||||
|
||||
// State: float/trickle
|
||||
true, // trickle_enabled;
|
||||
2.3, // cell_voltage_trickle; // target voltage for trickle charging of lead-acid batteries
|
||||
30*60, // time_trickle_recharge; // sec
|
||||
|
||||
// State: equalization
|
||||
false, // equalization_enabled;
|
||||
2.5, // cell_voltage_equalization; // V
|
||||
60, // time_limit_equalization; // sec
|
||||
1.0, // current_limit_equalization; // A
|
||||
8, // equalization_trigger_time; // weeks
|
||||
10, // equalization_trigger_deep_cycles; // times
|
||||
|
||||
1.95, // cell_voltage_load_disconnect;
|
||||
2.2, // cell_voltage_load_reconnect;
|
||||
|
||||
// TODO
|
||||
1.0 // temperature_compensation;
|
||||
};
|
||||
|
||||
const int cell_voltage_load_disconnect = 1950;
|
||||
const int cell_voltage_load_reconnect = 2200;
|
||||
|
||||
/*
|
||||
// typcial LiFePO4 battery
|
||||
|
||||
+45
-30
@@ -52,7 +52,9 @@ DigitalOut led_green(PIN_LED_GREEN);
|
||||
DigitalOut led_red(PIN_LED_RED);
|
||||
DigitalOut load_disable(PIN_LOAD_DIS);
|
||||
|
||||
//AnalogOut ref_i_dcdc(PIN_REF_I_DCDC);
|
||||
#ifdef MPPT_20A
|
||||
AnalogOut ref_i_dcdc(PIN_REF_I_DCDC);
|
||||
#endif
|
||||
|
||||
AnalogIn v_ref(PIN_V_REF);
|
||||
|
||||
@@ -63,14 +65,18 @@ AnalogValue dcdc_current(PIN_I_DCDC, 1000 / 2 / (1500.0 / 22.0)); // op amp gain
|
||||
AnalogValue load_current(PIN_I_LOAD, 1000 / 2 / (1500.0 / 22.0));
|
||||
AnalogValue thermistor_voltage(PIN_TEMP_INT, 1.0);
|
||||
#endif
|
||||
#ifdef MPPT_12A
|
||||
AnalogValue solar_voltage(PIN_V_SOLAR, 156.8 / 6.8); // solar voltage divider o-- 100k --o-- 5.6k --o
|
||||
AnalogValue battery_voltage(PIN_V_BAT, 130 / 10); // battery voltage divider o-- 100k --o-- 10k --o
|
||||
AnalogValue dcdc_current(PIN_I_DCDC, 1000 / 5 / 50); // op amp gain: 150/2.2 = 68.2, resistor: 2 mOhm
|
||||
AnalogValue load_current(PIN_I_LOAD, 1000 / 5 / 50);
|
||||
AnalogValue thermistor_voltage(PIN_TEMP_INT, 1.0);
|
||||
#endif
|
||||
|
||||
ChargeController charger(profile);
|
||||
|
||||
float temperature; // °C
|
||||
|
||||
int dcdc_current_offset = 0;
|
||||
int load_current_offset = 0;
|
||||
|
||||
// for daily energy counting
|
||||
int seconds_zero_solar = 0;
|
||||
int seconds_day = 0;
|
||||
@@ -88,7 +94,6 @@ void setup();
|
||||
void update_measurements();
|
||||
void update_screen();
|
||||
void energy_counter();
|
||||
void load_management();
|
||||
void log_data();
|
||||
void rtc_write_backup_reg(uint32_t BackupRegister, uint32_t data);
|
||||
uint32_t rtc_read_backup_reg(uint32_t BackupRegister);
|
||||
@@ -105,7 +110,8 @@ int main()
|
||||
time_t last_second = time(NULL);
|
||||
|
||||
tick1.attach(&update_measurements, 0.01);
|
||||
tick2.attach(&update_mppt, 0.1);
|
||||
tick2.attach(&update_mppt, 0.05);
|
||||
//dcdc.start(0.5); // for testing only (don't run update_mppt!)
|
||||
|
||||
//time_state_changed = time(NULL) - 60*60*24; // start immediately
|
||||
|
||||
@@ -113,9 +119,21 @@ int main()
|
||||
// called once per second
|
||||
if (time(NULL) - last_second >= 1) {
|
||||
last_second = time(NULL);
|
||||
|
||||
// updates charger state machine
|
||||
charger.update(battery_voltage.read(), dcdc_current.read());
|
||||
|
||||
// load management
|
||||
if (charger.discharging_enabled()) {
|
||||
load_disable = 0;
|
||||
} else {
|
||||
load_disable = 1;
|
||||
}
|
||||
|
||||
energy_counter();
|
||||
update_screen();
|
||||
log_data();
|
||||
fflush(stdout);
|
||||
}
|
||||
sleep(); // wake-up by ticker interrupts
|
||||
}
|
||||
@@ -126,7 +144,10 @@ void setup()
|
||||
{
|
||||
led_green = 1;
|
||||
load_disable = 1;
|
||||
// ref_i_dcdc = 0; // 0 for buck, 1 for boost (TODO)
|
||||
|
||||
#ifdef MPPT_20A
|
||||
ref_i_dcdc = 0.1; // 0 for buck, 1 for boost (TODO)
|
||||
#endif
|
||||
|
||||
// for RTC backup register
|
||||
__PWR_CLK_ENABLE(); // normally in SystemClock_Config()
|
||||
@@ -134,20 +155,20 @@ void setup()
|
||||
|
||||
set_time(rtc_read_backup_reg(0));
|
||||
|
||||
input_Wh_day = (float)rtc_read_backup_reg(1) / 1000.0; // mWh
|
||||
output_Wh_day = (float)rtc_read_backup_reg(2) / 1000.0; // mWh
|
||||
input_Wh_total = (float)rtc_read_backup_reg(3); // Wh
|
||||
output_Wh_total = (float)rtc_read_backup_reg(4); // Wh
|
||||
input_Wh_day = rtc_read_backup_reg(1);
|
||||
output_Wh_day = rtc_read_backup_reg(2);
|
||||
input_Wh_total = rtc_read_backup_reg(3);
|
||||
output_Wh_total = rtc_read_backup_reg(4);
|
||||
|
||||
dcdc.deadtime_ns(300);
|
||||
dcdc.lock_settings();
|
||||
dcdc.duty_cycle_limits((float) profile.cell_voltage_load_disconnect * profile.num_cells / solar_voltage_max, 0.97);
|
||||
|
||||
wait(0.2);
|
||||
update_measurements();
|
||||
|
||||
// calibration of current sensors in no load condition
|
||||
//load_current_offset = -load_current;
|
||||
//dcdc_current_offset = -dcdc_current;
|
||||
dcdc_current.calibrate_offset(0.0);
|
||||
load_current.calibrate_offset(0.0);
|
||||
|
||||
serial.baud(115200);
|
||||
serial.printf("\nSerial interface started...\n");
|
||||
@@ -159,19 +180,11 @@ void setup()
|
||||
freopen("/serial", "w", stdout); // retarget stdout
|
||||
}
|
||||
|
||||
void load_management()
|
||||
{
|
||||
if (charger.discharging_enabled()) {
|
||||
load_disable = 0;
|
||||
} else {
|
||||
load_disable = 1;
|
||||
}
|
||||
}
|
||||
|
||||
void update_mppt()
|
||||
{
|
||||
charger.update(battery_voltage.read(), dcdc_current.read());
|
||||
load_management();
|
||||
//serial.printf("B: %.2fV, %.2fA, S: %.2fV, Charger: %d, DCDC: %d, PWM: %.1f\n",
|
||||
// battery_voltage.read(), dcdc_current.read(), solar_voltage.read(),
|
||||
// charger.get_state(), dcdc.enabled(), dcdc.get_duty_cycle() * 100.0);
|
||||
|
||||
float dcdc_power_new = battery_voltage * dcdc_current;
|
||||
|
||||
@@ -187,6 +200,7 @@ void update_mppt()
|
||||
{
|
||||
dcdc.stop();
|
||||
led_red = 0;
|
||||
//serial.printf("DCDC stopped!\n");
|
||||
}
|
||||
|
||||
if (battery_voltage > charger.read_target_voltage()) {
|
||||
@@ -199,13 +213,14 @@ void update_mppt()
|
||||
// (otherwise current could get negative, i.e. into solar panel)
|
||||
dcdc.stop();
|
||||
led_red = 0;
|
||||
//serial.printf("DCDC stopped!\n");
|
||||
}
|
||||
}
|
||||
else if (dcdc_current > charger.read_target_current()) {
|
||||
// increase input voltage to decrease current
|
||||
dcdc.duty_cycle_step(-1);
|
||||
}
|
||||
else {
|
||||
else if (dcdc.enabled()) {
|
||||
//printf("MPPT\n");
|
||||
// start MPPT
|
||||
if (dcdc_power > dcdc_power_new) {
|
||||
@@ -252,10 +267,10 @@ void energy_counter()
|
||||
|
||||
// save values to RTC backup register
|
||||
rtc_write_backup_reg(0, time(NULL));
|
||||
rtc_write_backup_reg(1, (uint32_t)(input_Wh_day * 1000)); // mWh
|
||||
rtc_write_backup_reg(2, (uint32_t)(output_Wh_day * 1000)); // mWh
|
||||
rtc_write_backup_reg(3, (uint32_t)(input_Wh_total)); // kWh
|
||||
rtc_write_backup_reg(4, (uint32_t)(output_Wh_total)); // kWh
|
||||
rtc_write_backup_reg(1, input_Wh_day);
|
||||
rtc_write_backup_reg(2, output_Wh_day);
|
||||
rtc_write_backup_reg(3, input_Wh_total);
|
||||
rtc_write_backup_reg(4, output_Wh_total);
|
||||
}
|
||||
|
||||
void log_data()
|
||||
|
||||