PWM switch: Improve overvoltage protection

In situations with full battery and sufficient solar panel power, the
battery could reach a high voltage directly after start of the PWM switch
and the control algorithm was not fast enough to limit the voltage (it
takes up to 18s to reach 5% duty cycle after starting at 95%).

This commit increases the step size in the direction of reduced power
and introduces an overvoltage flag that results in restart with 5% duty
cycle if the previous stop was caused by an overvoltage event.
This commit is contained in:
Martin Jäger
2020-12-13 11:05:05 +01:00
parent 4f4bdc70ae
commit a2ab1ebd45
2 changed files with 35 additions and 4 deletions
+8 -2
View File
@@ -89,12 +89,18 @@ enum ErrorFlag {
*/
ERR_DCDC_HS_MOSFET_SHORT = 1U << 14,
/** Short-circuit in HS MOSFET
/** Overvoltage in HS MOSFET
*
* Set in Dcdc::control() and never cleared
* Set in DAQ alert and never cleared
*/
ERR_DCDC_HS_OVERVOLTAGE = 1U << 15,
/** Overvoltage caused by PWM switch
*
* Set and cleared in PwmSwitch::control()
*/
ERR_PWM_SWITCH_OVERVOLTAGE = 1U << 16,
/** Mask to catch all error flags (up to 32 errors)
*/
ERR_ANY_ERROR = UINT32_MAX,
+27 -2
View File
@@ -19,6 +19,7 @@ LOG_MODULE_REGISTER(pwm_switch, CONFIG_LOG_DEFAULT_LEVEL);
#include "mcu.h"
#include "daq.h"
#include "helper.h"
#include "setup.h"
#if DT_NODE_EXISTS(DT_CHILD(DT_PATH(outputs), pwm_switch))
@@ -74,6 +75,12 @@ void PwmSwitch::control()
off_timestamp = uptime();
LOG_INF("PWM charger stop, current = %d mA", (int)(current * 1000.0F));
}
else if (bus->voltage > bus->sink_control_voltage() + 0.3F) {
pwm_signal_stop();
off_timestamp = uptime();
dev_stat.set_error(ERR_PWM_SWITCH_OVERVOLTAGE);
LOG_INF("PWM charger stop, overvoltage.");
}
else if (bus->voltage > bus->sink_control_voltage() // bus voltage above target
|| current < neg_current_limit // port current limit exceeded
|| current < -PWM_CURRENT_MAX) // PCB current limit exceeded
@@ -90,10 +97,14 @@ void PwmSwitch::control()
// prevent very short on periods and switch completely off instead
pwm_signal_stop();
off_timestamp = uptime();
// consider this as overvoltage in order to start again with 5% duty cycle
dev_stat.set_error(ERR_PWM_SWITCH_OVERVOLTAGE);
LOG_INF("PWM charger stop, no further derating possible.");
}
else {
pwm_signal_duty_cycle_step(-1);
// decrease the power with large steps to prevent long-term overvoltages if
// the PWM switch was started with full battery and high solar irradiation
pwm_signal_duty_cycle_step(-10);
}
}
else {
@@ -107,6 +118,12 @@ void PwmSwitch::control()
pwm_signal_duty_cycle_step(1);
}
}
if (dev_stat.has_error(ERR_PWM_SWITCH_OVERVOLTAGE) &&
bus->voltage < bus->sink_control_voltage() - 0.5F)
{
dev_stat.clear_error(ERR_PWM_SWITCH_OVERVOLTAGE);
}
}
else {
if (bus->sink_current_margin > 0 // charging allowed
@@ -117,7 +134,15 @@ void PwmSwitch::control()
{
// turning the PWM switch on creates a short voltage rise, so inhibit alerts by 50 ms
adc_upper_alert_inhibit(ADC_POS(v_low), 50);
pwm_signal_start(1);
if (dev_stat.has_error(ERR_PWM_SWITCH_OVERVOLTAGE)) {
// start with minimum duty cycle in order to prevent another overvoltage event
pwm_signal_start(0.05F);
}
else {
pwm_signal_start(1.0F);
}
power_good_timestamp = uptime();
LOG_INF("PWM charger start.");
}