Move thermal model parameters to DTS

This commit is contained in:
Martin Jäger
2020-05-06 12:53:26 +02:00
parent 38125f3da3
commit 4e6f6c7365
14 changed files with 220 additions and 243 deletions
+7 -8
View File
@@ -43,13 +43,12 @@ void LoadOutput::control()
// junction temperature calculation model for overcurrent detection
junction_temperature = junction_temperature + (
dev_stat.internal_temp - junction_temperature +
current * current /
(LOAD_CURRENT_MAX * LOAD_CURRENT_MAX) *
(CONFIG_MOSFET_MAX_JUNCTION_TEMP - CONFIG_INTERNAL_MAX_REFERENCE_TEMP)
) / (CONFIG_MOSFET_THERMAL_TIME_CONSTANT * CONFIG_CONTROL_FREQUENCY);
dev_stat.internal_temp - junction_temperature + current * current /
(LOAD_CURRENT_MAX * LOAD_CURRENT_MAX) *
(DT_CHARGE_CONTROLLER_PCB_MOSFETS_TJ_MAX - DT_CHARGE_CONTROLLER_PCB_INTERNAL_TREF_MAX)
) / (DT_CHARGE_CONTROLLER_PCB_MOSFETS_TAU_JA * CONFIG_CONTROL_FREQUENCY);
if (junction_temperature > CONFIG_MOSFET_MAX_JUNCTION_TEMP ||
if (junction_temperature > DT_CHARGE_CONTROLLER_PCB_MOSFETS_TJ_MAX ||
current > LOAD_CURRENT_MAX * 2)
{
flags_set(&error_flags, ERR_LOAD_OVERCURRENT);
@@ -69,7 +68,7 @@ void LoadOutput::control()
// long-term overvoltage (overvoltage transients are detected as an ADC alert and switch
// off the solar input instead of the load output)
if (bus->voltage > overvoltage || bus->voltage >
DT_INST_0_CHARGE_CONTROLLER_LS_VOLTAGE_MAX)
DT_CHARGE_CONTROLLER_PCB_LS_VOLTAGE_MAX)
{
ov_debounce_counter++;
if (ov_debounce_counter > CONFIG_CONTROL_FREQUENCY) {
@@ -108,7 +107,7 @@ void LoadOutput::control()
if (flags_check(&error_flags, ERR_LOAD_OVERVOLTAGE) &&
bus->voltage < (overvoltage - ov_hysteresis) &&
bus->voltage < (DT_INST_0_CHARGE_CONTROLLER_LS_VOLTAGE_MAX - ov_hysteresis))
bus->voltage < (DT_CHARGE_CONTROLLER_PCB_LS_VOLTAGE_MAX - ov_hysteresis))
{
flags_clear(&error_flags, ERR_LOAD_OVERVOLTAGE);
}