Fine-tuning of battery/load UV/OV alerts

- Alerts now set to +-20% of actual measured voltage
- Hysteresis for load overvoltage reconnect setpoint made configurable
- Added check for PWM switch MOSFET driver undervoltage
This commit is contained in:
Martin Jaeger
2019-11-11 11:38:34 +01:00
parent f254c77ab6
commit 47954166be
5 changed files with 21 additions and 21 deletions
+2 -2
View File
@@ -37,7 +37,7 @@ void control_pgood_to_off_overvoltage()
load_init(&load);
load.state = LOAD_STATE_ON;
dev_stat.clear_error(ERR_ANY_ERROR);
port.voltage = 14.8;
port.voltage = port.sink_voltage_max + 0.6;
// increase debounce counter to 1 before limit
for (int i = 0; i < CONTROL_FREQUENCY; i++) {
@@ -252,7 +252,7 @@ void control_off_overvoltage_to_on_at_lower_voltage()
TEST_ASSERT_EQUAL(ERR_LOAD_OVERVOLTAGE, dev_stat.error_flags);
TEST_ASSERT_EQUAL(LOAD_STATE_OFF_OVERVOLTAGE, load.state);
port.voltage = port.sink_voltage_max - 0.6;
port.voltage = port.sink_voltage_max - load.ov_hysteresis - 0.1;
load.control();
TEST_ASSERT_EQUAL(0, dev_stat.error_flags);
TEST_ASSERT_EQUAL(LOAD_STATE_ON, load.state); // deprecated