Fine-tuning of battery/load UV/OV alerts
- Alerts now set to +-20% of actual measured voltage - Hysteresis for load overvoltage reconnect setpoint made configurable - Added check for PWM switch MOSFET driver undervoltage
This commit is contained in:
+2
-2
@@ -37,7 +37,7 @@ void control_pgood_to_off_overvoltage()
|
||||
load_init(&load);
|
||||
load.state = LOAD_STATE_ON;
|
||||
dev_stat.clear_error(ERR_ANY_ERROR);
|
||||
port.voltage = 14.8;
|
||||
port.voltage = port.sink_voltage_max + 0.6;
|
||||
|
||||
// increase debounce counter to 1 before limit
|
||||
for (int i = 0; i < CONTROL_FREQUENCY; i++) {
|
||||
@@ -252,7 +252,7 @@ void control_off_overvoltage_to_on_at_lower_voltage()
|
||||
TEST_ASSERT_EQUAL(ERR_LOAD_OVERVOLTAGE, dev_stat.error_flags);
|
||||
TEST_ASSERT_EQUAL(LOAD_STATE_OFF_OVERVOLTAGE, load.state);
|
||||
|
||||
port.voltage = port.sink_voltage_max - 0.6;
|
||||
port.voltage = port.sink_voltage_max - load.ov_hysteresis - 0.1;
|
||||
load.control();
|
||||
TEST_ASSERT_EQUAL(0, dev_stat.error_flags);
|
||||
TEST_ASSERT_EQUAL(LOAD_STATE_ON, load.state); // deprecated
|
||||
|
||||
Reference in New Issue
Block a user