Fine-tuning of battery/load UV/OV alerts
- Alerts now set to +-20% of actual measured voltage - Hysteresis for load overvoltage reconnect setpoint made configurable - Added check for PWM switch MOSFET driver undervoltage
This commit is contained in:
+9
-15
@@ -28,7 +28,7 @@
|
||||
#include "config.h" // user-specific configuration
|
||||
|
||||
#include "half_bridge.h" // PWM generation for DC/DC converter
|
||||
#include "hardware.h" // hardware-related functions like load switch, LED control, watchdog, etc.
|
||||
#include "hardware.h" // hardware-related functions like watchdog, etc.
|
||||
#include "dcdc.h" // DC/DC converter control (hardware independent)
|
||||
#include "pwm_switch.h" // PWM charge controller
|
||||
#include "bat_charger.h" // battery settings and charger state machine
|
||||
@@ -133,13 +133,9 @@ int main()
|
||||
control_timer_start(CONTROL_FREQUENCY);
|
||||
wait(0.1); // necessary to prevent MCU from randomly getting stuck here if PV panel is connected before battery
|
||||
|
||||
|
||||
sleep_manager_lock_deep_sleep(); // required to have sleep returning.
|
||||
/*
|
||||
The mBed Serial class calls this internal during "attach", this is why it work with ThingSet Serial enabled even
|
||||
without this statement. Might be an issue of the particular STM32F072 mBed code or may affect
|
||||
also STM32L073 platforms on mBed
|
||||
*/
|
||||
// The Mbed Serial class calls sleep_manager_lock_deep_sleep() internally during attach. If no
|
||||
// Serial is enabled, sleep does not always return in STM32F072, so we lock deep sleep manually
|
||||
sleep_manager_lock_deep_sleep();
|
||||
|
||||
// the main loop is suitable for slow tasks like communication (even blocking wait allowed)
|
||||
time_t last_call = timestamp;
|
||||
@@ -149,9 +145,8 @@ int main()
|
||||
uext.process_asap();
|
||||
|
||||
time_t now = timestamp;
|
||||
if (now >= last_call + 1 || now < last_call) { // called once per second (or slower if blocking wait occured somewhere)
|
||||
|
||||
//printf("Still alive... time: %d, mode: %d\n", (int)time(NULL), dcdc.mode);
|
||||
if (now >= last_call + 1 || now < last_call) {
|
||||
// called once per second (or slower if blocking wait occured somewhere)
|
||||
|
||||
charger.discharge_control(&bat_conf);
|
||||
charger.charge_control(&bat_conf);
|
||||
@@ -163,10 +158,6 @@ int main()
|
||||
bat_terminal.pass_voltage_targets(&pwm_port_int);
|
||||
#endif
|
||||
|
||||
// update regularly to cover changed battery configurations
|
||||
adc_set_lv_alerts(bat_conf.voltage_absolute_max * charger.num_batteries,
|
||||
bat_conf.voltage_absolute_min * charger.num_batteries);
|
||||
|
||||
eeprom_update();
|
||||
|
||||
leds_update_1s();
|
||||
@@ -193,6 +184,9 @@ void system_control()
|
||||
// convert ADC readings to meaningful measurement values
|
||||
update_measurements();
|
||||
|
||||
// alerts should trigger only for transients, so update based on actual voltage
|
||||
adc_set_lv_alerts(lv_terminal.voltage * 1.2, lv_terminal.voltage * 0.8);
|
||||
|
||||
#if FEATURE_PWM_SWITCH
|
||||
ports_update_current_limits(&pwm_port_int, &bat_terminal, &load_terminal);
|
||||
pwm_switch.control();
|
||||
|
||||
Reference in New Issue
Block a user