Fine-tuning of battery/load UV/OV alerts
- Alerts now set to +-20% of actual measured voltage - Hysteresis for load overvoltage reconnect setpoint made configurable - Added check for PWM switch MOSFET driver undervoltage
This commit is contained in:
+3
-2
@@ -200,6 +200,7 @@ LoadOutput::LoadOutput(PowerPort *pwr_port) :
|
||||
junction_temperature = 25; // starting point: 25°C
|
||||
oc_recovery_delay = 5*60; // default: 5 minutes
|
||||
lvd_recovery_delay = 60*60; // default: 1 hour
|
||||
ov_hysteresis = 0.3;
|
||||
|
||||
// analog comparator to detect short circuits and trigger immediate load switch-off
|
||||
short_circuit_comp_init();
|
||||
@@ -341,8 +342,8 @@ void LoadOutput::control()
|
||||
}
|
||||
|
||||
if (dev_stat.has_error(ERR_LOAD_OVERVOLTAGE) &&
|
||||
port->voltage < (port->sink_voltage_max - 0.5) &&
|
||||
port->voltage < (LOW_SIDE_VOLTAGE_MAX - 0.5))
|
||||
port->voltage < (port->sink_voltage_max - ov_hysteresis) &&
|
||||
port->voltage < (LOW_SIDE_VOLTAGE_MAX - ov_hysteresis))
|
||||
{
|
||||
dev_stat.clear_error(ERR_LOAD_OVERVOLTAGE);
|
||||
}
|
||||
|
||||