Power port: Zero-initialize all values to fix unit tests
This commit is contained in:
+10
-9
@@ -14,6 +14,7 @@
|
||||
|
||||
#include <stdint.h>
|
||||
#include <stdbool.h>
|
||||
#include <stddef.h>
|
||||
|
||||
class PowerPort; // forward-declaration
|
||||
|
||||
@@ -28,7 +29,7 @@ public:
|
||||
/**
|
||||
* Measured bus voltage
|
||||
*/
|
||||
float voltage;
|
||||
float voltage = 0;
|
||||
|
||||
/**
|
||||
* Filtered bus voltage
|
||||
@@ -53,7 +54,7 @@ public:
|
||||
* This value is the voltage at zero current. Values for other currents are calculated
|
||||
* using the droop resistance.
|
||||
*/
|
||||
float sink_voltage_intercept;
|
||||
float sink_voltage_intercept = 0;
|
||||
|
||||
/**
|
||||
* Lower voltage boundary where this bus may be used to source current.
|
||||
@@ -61,33 +62,33 @@ public:
|
||||
* This value is the voltage at zero current. Values for other currents are calculated
|
||||
* using the droop resistance.
|
||||
*/
|
||||
float src_voltage_intercept;
|
||||
float src_voltage_intercept = 0;
|
||||
|
||||
/**
|
||||
* Droop resistance to adjust voltage bounds for current in sourcing direction
|
||||
*
|
||||
* control voltage = nominal voltage - droop_res * current
|
||||
*/
|
||||
float src_droop_res;
|
||||
float src_droop_res = 0;
|
||||
|
||||
/**
|
||||
* Droop resistance to adjust voltage bounds for current in sinking direction
|
||||
*
|
||||
* control voltage = nominal voltage - droop_res * current
|
||||
*/
|
||||
float sink_droop_res;
|
||||
float sink_droop_res = 0;
|
||||
|
||||
/**
|
||||
* Pointer to current measurement that is used to determine the droop. This is typically the
|
||||
* battery or nanogrid terminal.
|
||||
*/
|
||||
float *ref_current;
|
||||
float *ref_current = NULL;
|
||||
|
||||
/**
|
||||
* Available additional current towards the DC bus until limits of the connected ports are
|
||||
* reached
|
||||
*/
|
||||
float sink_current_margin;
|
||||
float sink_current_margin = 0;
|
||||
|
||||
/**
|
||||
* Available additional current from the DC bus until limits of the connected ports are reached
|
||||
@@ -97,7 +98,7 @@ public:
|
||||
* we still get power via solar, current up to the amount of solar input can be diverted into
|
||||
* the load (until the margin gets 0 and the battery would be discharged).
|
||||
*/
|
||||
float src_current_margin;
|
||||
float src_current_margin = 0;
|
||||
|
||||
/**
|
||||
* Calculate current-compensated src control voltage, considering droop and series multiplier
|
||||
@@ -183,7 +184,7 @@ public:
|
||||
/**
|
||||
* Each power port is connected to a DC bus, containing relevant voltage information
|
||||
*/
|
||||
DcBus *bus;
|
||||
DcBus *bus = NULL;
|
||||
|
||||
/**
|
||||
* Measured current through this port (positive sign = current into the external device)
|
||||
|
||||
Reference in New Issue
Block a user