DAQ: Add high-side overvoltage alert limit

Also rename the functions which set the alert limits to set_xx_limit
instead of set_xx_alert.
This commit is contained in:
Martin Jäger
2020-11-05 20:37:03 +01:00
parent c6709f8f00
commit 42759947f8
7 changed files with 86 additions and 26 deletions
+25 -7
View File
@@ -97,11 +97,11 @@ void check_temperature_readings()
TEST_ASSERT_EQUAL_FLOAT(adcval.bat_temperature, round(charger.bat_temperature * 10) / 10);
}
void adc_alert_undervoltage_triggering()
void adc_alert_lv_undervoltage_triggering()
{
dev_stat.clear_error(ERR_ANY_ERROR);
battery_conf_init(&bat_conf, BAT_TYPE_LFP, 4, 100);
daq_set_lv_alerts(bat_conf.voltage_absolute_max, bat_conf.voltage_absolute_min);
daq_set_lv_limits(bat_conf.voltage_absolute_max, bat_conf.voltage_absolute_min);
prepare_adc_filtered();
adc_update_value(ADC_POS(v_low));
@@ -125,11 +125,11 @@ void adc_alert_undervoltage_triggering()
TEST_ASSERT_EQUAL(false, dev_stat.has_error(ERR_BAT_UNDERVOLTAGE)); // ToDo
}
void adc_alert_overvoltage_triggering()
void adc_alert_lv_overvoltage_triggering()
{
dev_stat.clear_error(ERR_ANY_ERROR);
battery_conf_init(&bat_conf, BAT_TYPE_LFP, 4, 100);
daq_set_lv_alerts(bat_conf.voltage_absolute_max, bat_conf.voltage_absolute_min);
daq_set_lv_limits(bat_conf.voltage_absolute_max, bat_conf.voltage_absolute_min);
prepare_adc_filtered();
adc_update_value(ADC_POS(v_low));
@@ -156,10 +156,27 @@ void adc_alert_overvoltage_triggering()
TEST_ASSERT_EQUAL(false, dev_stat.has_error(ERR_BAT_OVERVOLTAGE));
}
void adc_alert_hv_overvoltage_triggering()
{
dev_stat.clear_error(ERR_ANY_ERROR);
daq_set_hv_limit(DT_PROP(DT_PATH(pcb), hs_voltage_max));
prepare_adc_filtered();
adc_update_value(ADC_POS(v_high));
// overvoltage test
adcval.solar_voltage = 85.0F;
prepare_adc_readings(adcval);
adc_update_value(ADC_POS(v_high));
TEST_ASSERT_EQUAL(false, dev_stat.has_error(ERR_DCDC_HS_OVERVOLTAGE));
adc_update_value(ADC_POS(v_high));
TEST_ASSERT_EQUAL(true, dev_stat.has_error(ERR_DCDC_HS_OVERVOLTAGE));
TEST_ASSERT_EQUAL(DCDC_CONTROL_OFF, dcdc.state);
}
void adc_alert_overflow_prevention()
{
// try to set an alert that overflows the 12-bit ADC resolution
uint16_t limit = adc_get_alert_limit(1, UINT16_MAX + 1);
uint16_t limit = adc_raw_clamp(1, UINT16_MAX + 1);
TEST_ASSERT_EQUAL_HEX(UINT16_MAX, limit);
}
@@ -195,8 +212,9 @@ void daq_tests()
//RUN_TEST(check_temperature_readings); // TODO
RUN_TEST(adc_alert_undervoltage_triggering);
RUN_TEST(adc_alert_overvoltage_triggering);
RUN_TEST(adc_alert_lv_undervoltage_triggering);
RUN_TEST(adc_alert_lv_overvoltage_triggering);
RUN_TEST(adc_alert_hv_overvoltage_triggering);
RUN_TEST(adc_alert_overflow_prevention);
UNITY_END();