DAQ: Add high-side overvoltage alert limit

Also rename the functions which set the alert limits to set_xx_limit
instead of set_xx_alert.
This commit is contained in:
Martin Jäger
2020-11-05 20:37:03 +01:00
parent c6709f8f00
commit 42759947f8
7 changed files with 86 additions and 26 deletions
+5 -1
View File
@@ -44,6 +44,10 @@ void main(void)
// Data Acquisition (DAQ) setup
daq_setup();
#if DT_NODE_EXISTS(DT_PATH(dcdc))
daq_set_hv_limit(DT_PROP(DT_PATH(pcb), hs_voltage_max));
#endif
#if CONFIG_HV_TERMINAL_SOLAR || CONFIG_LV_TERMINAL_SOLAR || CONFIG_PWM_TERMINAL_SOLAR
solar_terminal.init_solar();
#endif
@@ -138,7 +142,7 @@ void control_thread()
daq_update();
// alerts should trigger only for transients, so update based on actual voltage
daq_set_lv_alerts(lv_terminal.bus->voltage * 1.2F, lv_terminal.bus->voltage * 0.8F);
daq_set_lv_limits(lv_terminal.bus->voltage * 1.2F, lv_terminal.bus->voltage * 0.8F);
lv_terminal.update_bus_current_margins();