PowerPort member variables renamed
Previous naming with chg/dis didn't make much sense e.g. for load output or solar panels. Voltage targets are now named with source or sink. Current limits are defined based on their direction (negative or positive). ASCII art graphic added for better explanation of passive sign convention.
This commit is contained in:
+8
-8
@@ -144,7 +144,7 @@ PwmSwitch::PwmSwitch(PowerPort *pwm_terminal, PowerPort *pwm_port_int)
|
||||
void PwmSwitch::control()
|
||||
{
|
||||
if (_pwm_active) {
|
||||
if (port_int->chg_current_limit == 0 || terminal->dis_current_limit == 0
|
||||
if (port_int->pos_current_limit == 0 || terminal->neg_current_limit == 0
|
||||
|| terminal->current > 0 // discharging battery into solar panel --> stop
|
||||
|| enabled == false)
|
||||
{
|
||||
@@ -152,9 +152,9 @@ void PwmSwitch::control()
|
||||
off_timestamp = time(NULL);
|
||||
printf("PWM charger stop.\n");
|
||||
}
|
||||
else if (port_int->voltage > (port_int->chg_voltage_target - port_int->chg_droop_res * port_int->current) // output voltage above target
|
||||
|| port_int->current > port_int->chg_current_limit // output current limit exceeded
|
||||
|| terminal->current < terminal->dis_current_limit) // input current (negative signs) above limit
|
||||
else if (port_int->voltage > (port_int->sink_voltage_max - port_int->pos_droop_res * port_int->current) // output voltage above target
|
||||
|| port_int->current > port_int->pos_current_limit // output current limit exceeded
|
||||
|| terminal->current < terminal->neg_current_limit) // input current (negative signs) above limit
|
||||
{
|
||||
// The gate driver switch-off time is quite high (fall time around 1ms), so very short
|
||||
// on or off periods (duty cycle close to 0 and 1) should be avoided
|
||||
@@ -183,10 +183,10 @@ void PwmSwitch::control()
|
||||
}
|
||||
}
|
||||
else {
|
||||
if (port_int->chg_current_limit > 0 // charging allowed
|
||||
&& port_int->voltage < port_int->chg_voltage_target
|
||||
&& port_int->voltage > port_int->chg_voltage_min
|
||||
&& terminal->dis_current_limit < 0 // dischraging allowed
|
||||
if (port_int->pos_current_limit > 0 // charging allowed
|
||||
&& port_int->voltage < port_int->sink_voltage_max
|
||||
&& port_int->voltage > port_int->sink_voltage_min
|
||||
&& terminal->neg_current_limit < 0 // discharging allowed
|
||||
&& terminal->voltage > port_int->voltage + offset_voltage_start
|
||||
&& time(NULL) > (off_timestamp + restart_interval)
|
||||
&& enabled == true)
|
||||
|
||||
Reference in New Issue