From 42751c83c20995215bd85e0fb7c855232c821c55 Mon Sep 17 00:00:00 2001 From: Martin Jaeger <17674105+martinjaeger@users.noreply.github.com> Date: Wed, 23 Oct 2019 09:38:21 +0200 Subject: [PATCH] PowerPort member variables renamed Previous naming with chg/dis didn't make much sense e.g. for load output or solar panels. Voltage targets are now named with source or sink. Current limits are defined based on their direction (negative or positive). ASCII art graphic added for better explanation of passive sign convention. --- src/bat_charger.cpp | 64 +++++++++++++++++++------------------- src/data_objects.cpp | 12 +++---- src/dcdc.cpp | 32 +++++++++---------- src/load.cpp | 6 ++-- src/log.cpp | 16 +++++----- src/power_port.cpp | 40 ++++++++++++------------ src/power_port.h | 54 +++++++++++++++++++++++--------- src/pwm_switch.cpp | 16 +++++----- src/uext/uext_oled.cpp | 2 +- test/tests_bat_charger.cpp | 18 +++++------ test/tests_dcdc.cpp | 24 +++++++------- test/tests_log.cpp | 24 +++++++------- test/tests_power_port.cpp | 44 +++++++++++++------------- 13 files changed, 189 insertions(+), 163 deletions(-) diff --git a/src/bat_charger.cpp b/src/bat_charger.cpp index 940cacb..ebe59f7 100644 --- a/src/bat_charger.cpp +++ b/src/bat_charger.cpp @@ -266,12 +266,12 @@ void Charger::enter_state(int next_state) void Charger::discharge_control(BatConf *bat_conf) { // load output state is defined by battery bus dis_allowed flag - if (port->dis_current_limit < 0 // discharging allowed + if (port->neg_current_limit < 0 // discharging allowed && port->voltage < num_batteries * - (bat_conf->voltage_load_disconnect - port->current * port->dis_droop_res)) + (bat_conf->voltage_load_disconnect - port->current * port->neg_droop_res)) { // low state of charge - port->dis_current_limit = 0; + port->neg_current_limit = 0; num_deep_discharges++; if (usable_capacity < 0.1) { @@ -290,22 +290,22 @@ void Charger::discharge_control(BatConf *bat_conf) // simple SOH estimation soh = usable_capacity / bat_conf->nominal_capacity; } - else if (port->dis_current_limit < 0 + else if (port->neg_current_limit < 0 && (bat_temperature > bat_conf->discharge_temp_max || bat_temperature < bat_conf->discharge_temp_min)) { // temperature limits exceeded - port->dis_current_limit = 0; + port->neg_current_limit = 0; } if (port->voltage >= num_batteries * - (bat_conf->voltage_load_reconnect - port->current * port->dis_droop_res) + (bat_conf->voltage_load_reconnect - port->current * port->neg_droop_res) && bat_temperature < bat_conf->discharge_temp_max - 1 && bat_temperature > bat_conf->discharge_temp_min + 1) { // discharge current is stored as absolute value in bat_conf, but defined // as negative current for dc_bus - port->dis_current_limit = -bat_conf->discharge_current_max; + port->neg_current_limit = -bat_conf->discharge_current_max; } } @@ -315,7 +315,7 @@ void Charger::charge_control(BatConf *bat_conf) if (bat_temperature > bat_conf->charge_temp_max || bat_temperature < bat_conf->charge_temp_min) { - port->chg_current_limit = 0; + port->pos_current_limit = 0; enter_state(CHG_STATE_IDLE); } @@ -327,9 +327,9 @@ void Charger::charge_control(BatConf *bat_conf) && bat_temperature < bat_conf->charge_temp_max - 1 && bat_temperature > bat_conf->charge_temp_min + 1) { - port->chg_voltage_target = num_batteries * (bat_conf->topping_voltage + + port->sink_voltage_max = num_batteries * (bat_conf->topping_voltage + bat_conf->temperature_compensation * (bat_temperature - 25)); - port->chg_current_limit = bat_conf->charge_current_max; + port->pos_current_limit = bat_conf->charge_current_max; full = false; enter_state(CHG_STATE_BULK); } @@ -337,11 +337,11 @@ void Charger::charge_control(BatConf *bat_conf) } case CHG_STATE_BULK: { // continuously adjust voltage setting for temperature compensation - port->chg_voltage_target = num_batteries * (bat_conf->topping_voltage + + port->sink_voltage_max = num_batteries * (bat_conf->topping_voltage + bat_conf->temperature_compensation * (bat_temperature - 25)); if (port->voltage > num_batteries * - (port->chg_voltage_target - port->current * port->chg_droop_res)) + (port->sink_voltage_max - port->current * port->pos_droop_res)) { enter_state(CHG_STATE_TOPPING); } @@ -349,11 +349,11 @@ void Charger::charge_control(BatConf *bat_conf) } case CHG_STATE_TOPPING: { // continuously adjust voltage setting for temperature compensation - port->chg_voltage_target = num_batteries * (bat_conf->topping_voltage + + port->sink_voltage_max = num_batteries * (bat_conf->topping_voltage + bat_conf->temperature_compensation * (bat_temperature - 25)); if (port->voltage >= num_batteries * - (port->chg_voltage_target - port->current * port->chg_droop_res)) + (port->sink_voltage_max - port->current * port->pos_droop_res)) { time_voltage_limit_reached = time(NULL); } @@ -375,17 +375,17 @@ void Charger::charge_control(BatConf *bat_conf) num_deep_discharges - deep_dis_last_equalization >= bat_conf->equalization_trigger_deep_cycles)) { - port->chg_voltage_target = bat_conf->equalization_voltage; - port->chg_current_limit = bat_conf->equalization_current_limit; + port->sink_voltage_max = bat_conf->equalization_voltage; + port->pos_current_limit = bat_conf->equalization_current_limit; enter_state(CHG_STATE_EQUALIZATION); } else if (bat_conf->trickle_enabled) { - port->chg_voltage_target = num_batteries * (bat_conf->trickle_voltage + + port->sink_voltage_max = num_batteries * (bat_conf->trickle_voltage + bat_conf->temperature_compensation * (bat_temperature - 25)); enter_state(CHG_STATE_TRICKLE); } else { - port->chg_current_limit = 0; + port->pos_current_limit = 0; enter_state(CHG_STATE_IDLE); } } @@ -393,18 +393,18 @@ void Charger::charge_control(BatConf *bat_conf) } case CHG_STATE_TRICKLE: { // continuously adjust voltage setting for temperature compensation - port->chg_voltage_target = num_batteries * (bat_conf->trickle_voltage + + port->sink_voltage_max = num_batteries * (bat_conf->trickle_voltage + bat_conf->temperature_compensation * (bat_temperature - 25)); if (port->voltage >= num_batteries * - (port->chg_voltage_target - port->current * port->chg_droop_res)) + (port->sink_voltage_max - port->current * port->pos_droop_res)) { time_voltage_limit_reached = time(NULL); } if (time(NULL) - time_voltage_limit_reached > bat_conf->trickle_recharge_time) { - port->chg_current_limit = bat_conf->charge_current_max; + port->pos_current_limit = bat_conf->charge_current_max; full = false; enter_state(CHG_STATE_BULK); } @@ -414,7 +414,7 @@ void Charger::charge_control(BatConf *bat_conf) } case CHG_STATE_EQUALIZATION: { // continuously adjust voltage setting for temperature compensation - port->chg_voltage_target = num_batteries * (bat_conf->equalization_voltage + + port->sink_voltage_max = num_batteries * (bat_conf->equalization_voltage + bat_conf->temperature_compensation * (bat_temperature - 25)); // current or time limit for equalization reached @@ -427,12 +427,12 @@ void Charger::charge_control(BatConf *bat_conf) discharged_Ah = 0; // reset coulomb counter again if (bat_conf->trickle_enabled) { - port->chg_voltage_target = num_batteries * (bat_conf->trickle_voltage + + port->sink_voltage_max = num_batteries * (bat_conf->trickle_voltage + bat_conf->temperature_compensation * (bat_temperature - 25)); enter_state(CHG_STATE_TRICKLE); } else { - port->chg_current_limit = 0; + port->pos_current_limit = 0; enter_state(CHG_STATE_IDLE); } } @@ -445,17 +445,17 @@ void battery_init_dc_bus(PowerPort *port, BatConf *bat, unsigned int num_batteri { unsigned int n = (num_batteries == 2 ? 2 : 1); // only 1 or 2 allowed - port->dis_voltage_start = bat->voltage_load_reconnect * n; - port->dis_voltage_stop = bat->voltage_load_disconnect * n; - port->dis_current_limit = -bat->discharge_current_max; + port->src_voltage_start = bat->voltage_load_reconnect * n; + port->src_voltage_stop = bat->voltage_load_disconnect * n; + port->neg_current_limit = -bat->discharge_current_max; // negative sign for compensation of actual resistance - port->dis_droop_res = -(bat->internal_resistance + -bat->wire_resistance) * n; + port->neg_droop_res = -(bat->internal_resistance + -bat->wire_resistance) * n; - port->chg_voltage_target = bat->topping_voltage * n; - port->chg_voltage_min = bat->voltage_absolute_min * n; - port->chg_current_limit = bat->charge_current_max; + port->sink_voltage_max = bat->topping_voltage * n; + port->sink_voltage_min = bat->voltage_absolute_min * n; + port->pos_current_limit = bat->charge_current_max; // negative sign for compensation of actual resistance - port->chg_droop_res = -bat->wire_resistance * n; + port->pos_droop_res = -bat->wire_resistance * n; } diff --git a/src/data_objects.cpp b/src/data_objects.cpp index f2c851f..8cf1476 100644 --- a/src/data_objects.cpp +++ b/src/data_objects.cpp @@ -138,8 +138,8 @@ const data_object_t data_objects[] = { {0x79, TS_OUTPUT, TS_READ_ALL, TS_T_UINT16, 0, (void*) &(dcdc.state), "DCDCState"}, #endif {0x7A, TS_OUTPUT, TS_READ_ALL, TS_T_FLOAT32, 2, (void*) &(solar_terminal.current), "Solar_A"}, - {0x7B, TS_OUTPUT, TS_READ_ALL, TS_T_FLOAT32, 2, (void*) &(bat_terminal.chg_voltage_target), "BatTarget_V"}, - {0x7C, TS_OUTPUT, TS_READ_ALL, TS_T_FLOAT32, 2, (void*) &(bat_terminal.chg_current_limit), "BatTarget_A"}, + {0x7B, TS_OUTPUT, TS_READ_ALL, TS_T_FLOAT32, 2, (void*) &(bat_terminal.sink_voltage_max), "BatTarget_V"}, + {0x7C, TS_OUTPUT, TS_READ_ALL, TS_T_FLOAT32, 2, (void*) &(bat_terminal.pos_current_limit), "BatTarget_A"}, {0x7D, TS_OUTPUT, TS_READ_ALL, TS_T_FLOAT32, 2, (void*) &(bat_terminal.power), "Bat_W"}, {0x7E, TS_OUTPUT, TS_READ_ALL, TS_T_FLOAT32, 2, (void*) &(solar_terminal.power), "Solar_W"}, {0x7F, TS_OUTPUT, TS_READ_ALL, TS_T_FLOAT32, 2, (void*) &(load_terminal.power), "Load_W"}, @@ -158,10 +158,10 @@ const data_object_t data_objects[] = { {0x10, TS_REC, TS_READ_ALL | TS_WRITE_MAKER, TS_T_UINT16, 2, (void*) &(log_data.load_power_max_day), "LoadMaxDay_W"}, // accumulated data - {0xA0, TS_REC, TS_READ_ALL | TS_WRITE_MAKER, TS_T_FLOAT32, 2, (void*) &(solar_terminal.dis_energy_Wh), "SolarInDay_Wh"}, - {0xA1, TS_REC, TS_READ_ALL | TS_WRITE_MAKER, TS_T_FLOAT32, 2, (void*) &(load_terminal.chg_energy_Wh), "LoadOutDay_Wh"}, - {0xA2, TS_REC, TS_READ_ALL | TS_WRITE_MAKER, TS_T_FLOAT32, 2, (void*) &(bat_terminal.chg_energy_Wh), "BatChgDay_Wh"}, - {0xA3, TS_REC, TS_READ_ALL | TS_WRITE_MAKER, TS_T_FLOAT32, 2, (void*) &(bat_terminal.dis_energy_Wh), "BatDisDay_Wh"}, + {0xA0, TS_REC, TS_READ_ALL | TS_WRITE_MAKER, TS_T_FLOAT32, 2, (void*) &(solar_terminal.neg_energy_Wh), "SolarInDay_Wh"}, + {0xA1, TS_REC, TS_READ_ALL | TS_WRITE_MAKER, TS_T_FLOAT32, 2, (void*) &(load_terminal.pos_energy_Wh), "LoadOutDay_Wh"}, + {0xA2, TS_REC, TS_READ_ALL | TS_WRITE_MAKER, TS_T_FLOAT32, 2, (void*) &(bat_terminal.pos_energy_Wh), "BatChgDay_Wh"}, + {0xA3, TS_REC, TS_READ_ALL | TS_WRITE_MAKER, TS_T_FLOAT32, 2, (void*) &(bat_terminal.neg_energy_Wh), "BatDisDay_Wh"}, {0xA4, TS_REC, TS_READ_ALL | TS_WRITE_MAKER, TS_T_FLOAT32, 0, (void*) &(charger.discharged_Ah), "Dis_Ah"}, // coulomb counter {0xA5, TS_REC, TS_READ_ALL | TS_WRITE_MAKER, TS_T_UINT16, 0, (void*) &(charger.soh), "SOH_%"}, // output will be uint8_t {0xA6, TS_REC, TS_READ_ALL | TS_WRITE_MAKER, TS_T_INT32, 0, (void*) &(log_data.day_counter), "DayCount"}, diff --git a/src/dcdc.cpp b/src/dcdc.cpp index 0df0b3f..b300d80 100644 --- a/src/dcdc.cpp +++ b/src/dcdc.cpp @@ -84,7 +84,7 @@ int Dcdc::duty_cycle_delta() printf("P: %.2f, P_prev: %.2f, v_in: %.2f, v_out: %.2f, i_in: %.2f, i_out: %.2f, " "v_chg_target: %.2f, i_chg_max: %.2f, PWM: %.1f, chg_state: %d\n", out->power, power_prev, in->voltage, out->voltage, in->current, out->current, - out->chg_voltage_target, out->chg_current_limit, half_bridge_get_duty_cycle() * 100.0, + out->sink_voltage_max, out->pos_current_limit, half_bridge_get_duty_cycle() * 100.0, state); #endif @@ -93,13 +93,13 @@ int Dcdc::duty_cycle_delta() { pwr_inc_goal = 0; // switch off } - else if (out->voltage > (out->chg_voltage_target - out->chg_droop_res * out->current)) + else if (out->voltage > (out->sink_voltage_max - out->pos_droop_res * out->current)) { // output voltage target reached state = DCDC_STATE_CV; pwr_inc_goal = -1; // decrease output power } - else if (out->current > out->chg_current_limit) + else if (out->current > out->pos_current_limit) { // output charge current limit reached state = DCDC_STATE_CC; @@ -107,14 +107,14 @@ int Dcdc::duty_cycle_delta() } else if (fabs(lvs->current) > ls_current_max // current above hardware maximum || temp_mosfets > 80 // temperature limits exceeded - || (in->voltage < (in->dis_voltage_start - in->dis_droop_res * in->current) + || (in->voltage < (in->src_voltage_start - in->neg_droop_res * in->current) && out->current > 0.1) // input voltage below limit - || in->current < in->dis_current_limit) // input current (negative signs) limit exceeded + || in->current < in->neg_current_limit) // input current (negative signs) limit exceeded { state = DCDC_STATE_DERATING; pwr_inc_goal = -1; // decrease output power } - else if (out->power < output_power_min && out->voltage < out->dis_voltage_start) + else if (out->power < output_power_min && out->voltage < out->src_voltage_start) { // no load condition (e.g. start-up of nanogrid) --> raise voltage pwr_inc_goal = 1; // increase output power @@ -143,20 +143,20 @@ int Dcdc::check_start_conditions() return 0; // no energy transfer allowed } - if (lvs->chg_current_limit > 0 && - lvs->voltage < lvs->chg_voltage_target && - lvs->voltage > lvs->chg_voltage_min && - hvs->dis_current_limit < 0 && - hvs->voltage > hvs->dis_voltage_start) + if (lvs->pos_current_limit > 0 && + lvs->voltage < lvs->sink_voltage_max && + lvs->voltage > lvs->sink_voltage_min && + hvs->neg_current_limit < 0 && + hvs->voltage > hvs->src_voltage_start) { return 1; // start in buck mode allowed } - if (hvs->chg_current_limit > 0 && - hvs->voltage < hvs->chg_voltage_target && - hvs->voltage > hvs->chg_voltage_min && - lvs->dis_current_limit < 0 && - lvs->voltage > lvs->dis_voltage_start) + if (hvs->pos_current_limit > 0 && + hvs->voltage < hvs->sink_voltage_max && + hvs->voltage > hvs->sink_voltage_min && + lvs->neg_current_limit < 0 && + lvs->voltage > lvs->src_voltage_start) { return -1; // start in boost mode allowed } diff --git a/src/load.cpp b/src/load.cpp index adb5ae5..0cfdbb7 100644 --- a/src/load.cpp +++ b/src/load.cpp @@ -256,7 +256,7 @@ void LoadOutput::state_machine() //printf("Load State: %d\n", switch_state); switch (switch_state) { case LOAD_STATE_DISABLED: - if (port->dis_current_limit < 0 // discharging enabled + if (port->neg_current_limit < 0 // discharging enabled && enabled_target == true) { switch_set(true); @@ -268,7 +268,7 @@ void LoadOutput::state_machine() switch_set(false); switch_state = LOAD_STATE_DISABLED; } - else if (port->dis_current_limit == 0) { // float == is allowed for 0.0 + else if (port->neg_current_limit == 0) { // float == is allowed for 0.0 lvd_timestamp = time(NULL); switch_set(false); switch_state = LOAD_STATE_OFF_LOW_SOC; @@ -276,7 +276,7 @@ void LoadOutput::state_machine() break; case LOAD_STATE_OFF_LOW_SOC: // wait at least one hour - if (port->dis_current_limit < 0 // discharging enabled again + if (port->neg_current_limit < 0 // discharging enabled again && time(NULL) - lvd_timestamp > 60*60) { if (enabled_target == true) { diff --git a/src/log.cpp b/src/log.cpp index 525a7ed..da93cd2 100644 --- a/src/log.cpp +++ b/src/log.cpp @@ -52,22 +52,22 @@ void log_update_energy(LogData *log_data) load_out_total_Wh_prev = log_data->load_out_total_Wh; bat_chg_total_Wh_prev = log_data->bat_chg_total_Wh; bat_dis_total_Wh_prev = log_data->bat_dis_total_Wh; - solar_terminal.dis_energy_Wh = 0.0; - load_terminal.chg_energy_Wh = 0.0; - bat_terminal.chg_energy_Wh = 0.0; - bat_terminal.dis_energy_Wh = 0.0; + solar_terminal.neg_energy_Wh = 0.0; + load_terminal.pos_energy_Wh = 0.0; + bat_terminal.pos_energy_Wh = 0.0; + bat_terminal.neg_energy_Wh = 0.0; } seconds_zero_solar = 0; } log_data->bat_chg_total_Wh = bat_chg_total_Wh_prev + - (bat_terminal.chg_energy_Wh > 0 ? bat_terminal.chg_energy_Wh : 0); + (bat_terminal.pos_energy_Wh > 0 ? bat_terminal.pos_energy_Wh : 0); log_data->bat_dis_total_Wh = bat_dis_total_Wh_prev + - (bat_terminal.dis_energy_Wh > 0 ? bat_terminal.dis_energy_Wh : 0); + (bat_terminal.neg_energy_Wh > 0 ? bat_terminal.neg_energy_Wh : 0); log_data->solar_in_total_Wh = solar_in_total_Wh_prev + - (solar_terminal.dis_energy_Wh > 0 ? solar_terminal.dis_energy_Wh : 0); + (solar_terminal.neg_energy_Wh > 0 ? solar_terminal.neg_energy_Wh : 0); log_data->load_out_total_Wh = load_out_total_Wh_prev + - (load_terminal.chg_energy_Wh > 0 ? load_terminal.chg_energy_Wh : 0); + (load_terminal.pos_energy_Wh > 0 ? load_terminal.pos_energy_Wh : 0); } void log_update_min_max_values(LogData *log_data) diff --git a/src/power_port.cpp b/src/power_port.cpp index 7e56a67..6dc595f 100644 --- a/src/power_port.cpp +++ b/src/power_port.cpp @@ -18,28 +18,28 @@ void PowerPort::init_solar() { - dis_current_limit = -50; // derating based on max. DC/DC or PWM switch current only - chg_current_limit = 0; // no current towards solar panel allowed + neg_current_limit = -50; // derating based on max. DC/DC or PWM switch current only + pos_current_limit = 0; // no current towards solar panel allowed // also initialize the connected bus - dis_voltage_start = 16.0; - dis_voltage_stop = 14.0; + src_voltage_start = 16.0; + src_voltage_stop = 14.0; } void PowerPort::init_nanogrid() { - dis_current_limit = -5.0; - dis_droop_res = 0.1; // 1 Ohm means 1V change of target voltage per amp + neg_current_limit = -5.0; + neg_droop_res = 0.1; // 1 Ohm means 1V change of target voltage per amp - chg_current_limit = 5.0; - chg_droop_res = 0.1; // 1 Ohm means 1V change of target voltage per amp + pos_current_limit = 5.0; + pos_droop_res = 0.1; // 1 Ohm means 1V change of target voltage per amp // also initialize the connected bus - dis_voltage_start = 30.0; // starting buck mode above this point - dis_voltage_stop = 20.0; // stopping buck mode below this point + src_voltage_start = 30.0; // starting buck mode above this point + src_voltage_stop = 20.0; // stopping buck mode below this point - chg_voltage_target = 28.0; // starting idle mode above this point - chg_voltage_min = 10.0; + sink_voltage_max = 28.0; // starting idle mode above this point + sink_voltage_min = 10.0; } // must be called exactly once per second, otherwise energy calculation gets wrong @@ -47,28 +47,28 @@ void PowerPort::energy_balance() { // remark: timespan = 1s, so no multiplication with time necessary for energy calculation if (current >= 0) { - chg_energy_Wh += voltage * current / 3600.0; + pos_energy_Wh += voltage * current / 3600.0; } else { - dis_energy_Wh -= voltage * current / 3600.0; + neg_energy_Wh -= voltage * current / 3600.0; } } void PowerPort::pass_voltage_targets(PowerPort *port) { // droop resistance added only to limits where current actually flows - port->chg_voltage_min = chg_voltage_min; - port->chg_voltage_target = chg_voltage_target + chg_droop_res * current; - port->dis_voltage_start = dis_voltage_start + chg_droop_res * current; - port->dis_voltage_stop = dis_voltage_stop + chg_droop_res * current; + port->sink_voltage_min = sink_voltage_min; + port->sink_voltage_max = sink_voltage_max + pos_droop_res * current; + port->src_voltage_start = src_voltage_start + pos_droop_res * current; + port->src_voltage_stop = src_voltage_stop + pos_droop_res * current; } void ports_update_current_limits(PowerPort *p_dcdc, PowerPort *p_bat, PowerPort *p_load) { - p_dcdc->chg_current_limit = p_bat->chg_current_limit - p_bat->current + p_load->current; + p_dcdc->pos_current_limit = p_bat->pos_current_limit - p_bat->current + p_load->current; // this is a bit tricky... in theory, we could add the available DC/DC current to keep the // load switched on as long as solar power is available, even if the battery is empty. This // needs a fast point-of-load (PoL) control of the DC/DC, which is not possible (yet). - p_dcdc->dis_current_limit = p_bat->dis_current_limit - p_bat->current; + p_dcdc->neg_current_limit = p_bat->neg_current_limit - p_bat->current; } diff --git a/src/power_port.h b/src/power_port.h index 064b14e..0ead16e 100644 --- a/src/power_port.h +++ b/src/power_port.h @@ -24,37 +24,63 @@ #include + +// ----------------- +// | | >> positive current/power direction +// | o---->---- +// | | + | +// | considered | | | external device: battery / solar panel / load / DC grid +// | system or | | | +// | sub-circuit | | | (the port should be named after the external device) +// | | - | +// | o--------- +// | | +// ----------------- + /** Power Port class * * Stores actual measurements and voltage / current limits for external terminals or internal ports + * + * The signs follow the passive sign convention. Current or power from the considered system or + * circuit towards an external device connected to the port has a positive sign. For all terminals, + * the entire charge controller is considered as the system boundary and acts as a source or a sink. + * For internal sub-circuits, e.g. the DC/DC converter circuit defines the sub-system boundaries. + * + * Examples: + * - Charging a connected battery has a positive sign, as current flows from the charge controller + * into the battery, i.e. the battery acts as a sink. + * - Power from a solar panel (power source) has a negative sign, as the charge controller acts as + * the sink and power flows from the external device into the charge controller. + * - A DC/DC converter in buck mode results in a positive current flow at the low voltage side and + * a negative current at the high voltage side. The system boundary is the DC/DC sub-circuit, + * which sources current from the high side port and sinks it through the low side port. */ class PowerPort { public: - float voltage; ///< Measured bus voltage + float voltage; ///< Measured port voltage - float chg_voltage_target; ///< Target voltage if bus is charged - float chg_voltage_min; ///< Minimum voltage to allow charge current (necessary + float sink_voltage_max; ///< Maximum voltage if connected device acts as a sink + ///< (equivalent to battery charging target voltage) + float sink_voltage_min; ///< Minimum voltage to allow positive current (necessary ///< to prevent charging of deep-discharged Li-ion batteries) - float dis_voltage_start; ///< Minimum voltage to allow discharge current from the bus + float src_voltage_start; ///< Minimum voltage to allow source current from the device ///< (equal to load reconnect voltage) - float dis_voltage_stop; ///< Absolute minimum = load disconnect for batteries + float src_voltage_stop; ///< Absolute minimum = load disconnect for batteries float current; ///< Measured current through this port (positive sign = - ///< increasing voltage/charge of the named device) + ///< sinking current into the named external device) float power; ///< Product of current & voltage - float chg_current_limit; ///< Maximum current charging the bus, i.e. increasing its - ///< voltage (charging direction for battery terminal) - float chg_droop_res; ///< control voltage = nominal voltage - droop_res * current + float pos_current_limit; ///< Maximum positive current (valid values >= 0.0) + float pos_droop_res; ///< control voltage = nominal voltage - droop_res * current - float dis_current_limit; ///< Maximum current to discharge the bus, i.e. decrease its - ///< voltage, value must be negative!!! - float dis_droop_res; ///< control voltage = nominal voltage - droop_res * current + float neg_current_limit; ///< Maximum negative current (valid values <= 0.0) + float neg_droop_res; ///< control voltage = nominal voltage - droop_res * current - float chg_energy_Wh; ///< cumulated energy in charge direction since last counter reset (Wh) - float dis_energy_Wh; ///< cumulated energy in discharge direction since last counter reset (Wh) + float pos_energy_Wh; ///< Cumulated sunk energy since last counter reset (Wh) + float neg_energy_Wh; ///< Cumulated sourced energy since last counter reset (Wh) /** Initialize power port for solar panel connection * diff --git a/src/pwm_switch.cpp b/src/pwm_switch.cpp index 518ef64..8611e87 100644 --- a/src/pwm_switch.cpp +++ b/src/pwm_switch.cpp @@ -144,7 +144,7 @@ PwmSwitch::PwmSwitch(PowerPort *pwm_terminal, PowerPort *pwm_port_int) void PwmSwitch::control() { if (_pwm_active) { - if (port_int->chg_current_limit == 0 || terminal->dis_current_limit == 0 + if (port_int->pos_current_limit == 0 || terminal->neg_current_limit == 0 || terminal->current > 0 // discharging battery into solar panel --> stop || enabled == false) { @@ -152,9 +152,9 @@ void PwmSwitch::control() off_timestamp = time(NULL); printf("PWM charger stop.\n"); } - else if (port_int->voltage > (port_int->chg_voltage_target - port_int->chg_droop_res * port_int->current) // output voltage above target - || port_int->current > port_int->chg_current_limit // output current limit exceeded - || terminal->current < terminal->dis_current_limit) // input current (negative signs) above limit + else if (port_int->voltage > (port_int->sink_voltage_max - port_int->pos_droop_res * port_int->current) // output voltage above target + || port_int->current > port_int->pos_current_limit // output current limit exceeded + || terminal->current < terminal->neg_current_limit) // input current (negative signs) above limit { // The gate driver switch-off time is quite high (fall time around 1ms), so very short // on or off periods (duty cycle close to 0 and 1) should be avoided @@ -183,10 +183,10 @@ void PwmSwitch::control() } } else { - if (port_int->chg_current_limit > 0 // charging allowed - && port_int->voltage < port_int->chg_voltage_target - && port_int->voltage > port_int->chg_voltage_min - && terminal->dis_current_limit < 0 // dischraging allowed + if (port_int->pos_current_limit > 0 // charging allowed + && port_int->voltage < port_int->sink_voltage_max + && port_int->voltage > port_int->sink_voltage_min + && terminal->neg_current_limit < 0 // discharging allowed && terminal->voltage > port_int->voltage + offset_voltage_start && time(NULL) > (off_timestamp + restart_interval) && enabled == true) diff --git a/src/uext/uext_oled.cpp b/src/uext/uext_oled.cpp index 48980ac..47d3f7e 100644 --- a/src/uext/uext_oled.cpp +++ b/src/uext/uext_oled.cpp @@ -120,7 +120,7 @@ void uext_process_1s() oled.printf("%5.1fA\n", (abs(load_terminal.current) < 0.1) ? 0 : load_terminal.current); oled.setTextCursor(0, 36); - oled.printf("Day +%5.0fWh -%5.0fWh", solar_terminal.dis_energy_Wh, fabs(load_terminal.chg_energy_Wh)); + oled.printf("Day +%5.0fWh -%5.0fWh", solar_terminal.neg_energy_Wh, fabs(load_terminal.pos_energy_Wh)); oled.printf("Tot +%4.1fkWh -%4.1fkWh", log_data.solar_in_total_Wh / 1000.0, fabs(log_data.load_out_total_Wh) / 1000.0); oled.setTextCursor(0, 56); diff --git a/test/tests_bat_charger.cpp b/test/tests_bat_charger.cpp index c7af5f4..cc0b092 100644 --- a/test/tests_bat_charger.cpp +++ b/test/tests_bat_charger.cpp @@ -216,31 +216,31 @@ void stop_discharge_at_low_voltage() bat_terminal.voltage = 14; charger.discharge_control(&bat_conf); - TEST_ASSERT_LESS_THAN(0, bat_terminal.dis_current_limit); + TEST_ASSERT_LESS_THAN(0, bat_terminal.neg_current_limit); bat_terminal.voltage = bat_conf.voltage_load_disconnect - 0.1; charger.discharge_control(&bat_conf); - TEST_ASSERT_EQUAL(0, bat_terminal.dis_current_limit); + TEST_ASSERT_EQUAL(0, bat_terminal.neg_current_limit); } void stop_discharge_at_overtemp() { init_structs(); - TEST_ASSERT_LESS_THAN(0, bat_terminal.dis_current_limit); + TEST_ASSERT_LESS_THAN(0, bat_terminal.neg_current_limit); charger.bat_temperature = bat_conf.discharge_temp_max + 1; charger.discharge_control(&bat_conf); - TEST_ASSERT_EQUAL(0, bat_terminal.dis_current_limit); + TEST_ASSERT_EQUAL(0, bat_terminal.neg_current_limit); } void stop_discharge_at_undertemp() { init_structs(); - TEST_ASSERT_LESS_THAN(0, bat_terminal.dis_current_limit); + TEST_ASSERT_LESS_THAN(0, bat_terminal.neg_current_limit); charger.bat_temperature = bat_conf.discharge_temp_min - 1; charger.discharge_control(&bat_conf); - TEST_ASSERT_EQUAL(0, bat_terminal.dis_current_limit); + TEST_ASSERT_EQUAL(0, bat_terminal.neg_current_limit); } void restart_discharge_if_allowed() @@ -250,17 +250,17 @@ void restart_discharge_if_allowed() // stop because of undervoltage bat_terminal.voltage = bat_conf.voltage_load_disconnect - 0.1; charger.discharge_control(&bat_conf); - TEST_ASSERT_EQUAL(0, bat_terminal.dis_current_limit); + TEST_ASSERT_EQUAL(0, bat_terminal.neg_current_limit); // increase voltage slightly above DISconnect voltage bat_terminal.voltage = bat_conf.voltage_load_disconnect + 0.1; charger.discharge_control(&bat_conf); - TEST_ASSERT_EQUAL(0, bat_terminal.dis_current_limit); + TEST_ASSERT_EQUAL(0, bat_terminal.neg_current_limit); // increase voltage above REconnect voltage bat_terminal.voltage = bat_conf.voltage_load_reconnect + 0.1; charger.discharge_control(&bat_conf); - TEST_ASSERT_LESS_THAN(0, bat_terminal.dis_current_limit); + TEST_ASSERT_LESS_THAN(0, bat_terminal.neg_current_limit); } void battery_values_propagated_to_lv_bus_int() diff --git a/test/tests_dcdc.cpp b/test/tests_dcdc.cpp index 00a017d..38bf212 100644 --- a/test/tests_dcdc.cpp +++ b/test/tests_dcdc.cpp @@ -13,7 +13,7 @@ static void init_structs_buck() { hv_terminal.init_solar(); hv_terminal.voltage = 20; - hv_terminal.dis_voltage_start = 18; + hv_terminal.src_voltage_start = 18; hv_terminal.current = 0; battery_conf_init(&bat_conf, BAT_TYPE_GEL, 6, 100); @@ -45,7 +45,7 @@ static void init_structs_boost() hv_terminal.init_solar(); dcdc_lv_port.voltage = 20; - dcdc_lv_port.dis_voltage_start = 18; + dcdc_lv_port.src_voltage_start = 18; dcdc_lv_port.current = 0; dcdc_lv_port.power = 0; @@ -127,7 +127,7 @@ void no_buck_start_if_bat_voltage_high() void no_buck_start_if_bat_chg_not_allowed() { init_structs_buck(); - dcdc_lv_port.chg_current_limit = 0; + dcdc_lv_port.pos_current_limit = 0; TEST_ASSERT_EQUAL(0, dcdc.check_start_conditions()); } @@ -164,7 +164,7 @@ void no_boost_start_if_bat_voltage_high() void no_boost_start_if_bat_chg_not_allowed() { init_structs_boost(); - hv_terminal.chg_current_limit = 0; + hv_terminal.pos_current_limit = 0; TEST_ASSERT_EQUAL(0, dcdc.check_start_conditions()); } @@ -197,7 +197,7 @@ void buck_derating_output_voltage_too_high() { start_buck(); float pwm_before = half_bridge_get_duty_cycle(); - dcdc_lv_port.voltage = dcdc_lv_port.chg_voltage_target + 0.1; + dcdc_lv_port.voltage = dcdc_lv_port.sink_voltage_max + 0.1; dcdc.control(); float pwm_after = half_bridge_get_duty_cycle(); TEST_ASSERT(pwm_after < pwm_before); // less duty cycle = higher voltage @@ -208,7 +208,7 @@ void buck_derating_output_current_too_high() { start_buck(); float pwm_before = half_bridge_get_duty_cycle(); - dcdc_lv_port.current = dcdc_lv_port.chg_current_limit + 0.1; + dcdc_lv_port.current = dcdc_lv_port.pos_current_limit + 0.1; dcdc.control(); float pwm_after = half_bridge_get_duty_cycle(); TEST_ASSERT(pwm_after < pwm_before); @@ -219,7 +219,7 @@ void buck_derating_input_voltage_too_low() { start_buck(); float pwm_before = half_bridge_get_duty_cycle(); - hv_terminal.voltage = hv_terminal.dis_voltage_stop - 0.1; + hv_terminal.voltage = hv_terminal.src_voltage_stop - 0.1; dcdc_lv_port.current = 0.2; dcdc.control(); float pwm_after = half_bridge_get_duty_cycle(); @@ -231,7 +231,7 @@ void buck_derating_input_current_too_high() { start_buck(); float pwm_before = half_bridge_get_duty_cycle(); - hv_terminal.current = hv_terminal.dis_current_limit - 0.1; + hv_terminal.current = hv_terminal.neg_current_limit - 0.1; dcdc.control(); float pwm_after = half_bridge_get_duty_cycle(); TEST_ASSERT(pwm_after < pwm_before); @@ -300,7 +300,7 @@ void boost_derating_output_voltage_too_high() { start_boost(); float pwm_before = half_bridge_get_duty_cycle(); - hv_terminal.voltage = hv_terminal.chg_voltage_target + 0.5; + hv_terminal.voltage = hv_terminal.sink_voltage_max + 0.5; dcdc.control(); float pwm_after = half_bridge_get_duty_cycle(); TEST_ASSERT(pwm_after > pwm_before); // higher duty cycle = less power @@ -310,7 +310,7 @@ void boost_derating_output_current_too_high() { start_boost(); float pwm_before = half_bridge_get_duty_cycle(); - hv_terminal.current = hv_terminal.chg_current_limit + 0.1; + hv_terminal.current = hv_terminal.pos_current_limit + 0.1; dcdc.control(); float pwm_after = half_bridge_get_duty_cycle(); TEST_ASSERT(pwm_after > pwm_before); @@ -320,7 +320,7 @@ void boost_derating_input_voltage_too_low() { start_boost(); float pwm_before = half_bridge_get_duty_cycle(); - dcdc_lv_port.voltage = dcdc_lv_port.dis_voltage_stop - 0.1; + dcdc_lv_port.voltage = dcdc_lv_port.src_voltage_stop - 0.1; hv_terminal.current = 0.2; dcdc.control(); float pwm_after = half_bridge_get_duty_cycle(); @@ -331,7 +331,7 @@ void boost_derating_input_current_too_high() { start_boost(); float pwm_before = half_bridge_get_duty_cycle(); - dcdc_lv_port.current = dcdc_lv_port.dis_current_limit - 0.1; + dcdc_lv_port.current = dcdc_lv_port.neg_current_limit - 0.1; dcdc.control(); float pwm_after = half_bridge_get_duty_cycle(); TEST_ASSERT(pwm_after > pwm_before); diff --git a/test/tests_log.cpp b/test/tests_log.cpp index a424a9a..a3ec438 100644 --- a/test/tests_log.cpp +++ b/test/tests_log.cpp @@ -13,10 +13,10 @@ void reset_counters_at_start_of_day() log_data.day_counter = 0; - solar_terminal.dis_energy_Wh = 10.0; - bat_terminal.dis_energy_Wh = 3.0; - bat_terminal.chg_energy_Wh = 4.0; - load_terminal.chg_energy_Wh = 9.0; + solar_terminal.neg_energy_Wh = 10.0; + bat_terminal.neg_energy_Wh = 3.0; + bat_terminal.pos_energy_Wh = 4.0; + load_terminal.pos_energy_Wh = 9.0; // 5 houurs without sun for (int i = 0; i <= 5 * 60 * 60; i++) { @@ -28,10 +28,10 @@ void reset_counters_at_start_of_day() TEST_ASSERT_EQUAL(4, log_data.bat_chg_total_Wh); TEST_ASSERT_EQUAL(9, log_data.load_out_total_Wh); - TEST_ASSERT_EQUAL(10, solar_terminal.dis_energy_Wh); - TEST_ASSERT_EQUAL(3, bat_terminal.dis_energy_Wh); - TEST_ASSERT_EQUAL(4, bat_terminal.chg_energy_Wh); - TEST_ASSERT_EQUAL(9, load_terminal.chg_energy_Wh); + TEST_ASSERT_EQUAL(10, solar_terminal.neg_energy_Wh); + TEST_ASSERT_EQUAL(3, bat_terminal.neg_energy_Wh); + TEST_ASSERT_EQUAL(4, bat_terminal.pos_energy_Wh); + TEST_ASSERT_EQUAL(9, load_terminal.pos_energy_Wh); // solar didn't come back yet TEST_ASSERT_EQUAL(0, log_data.day_counter); @@ -42,10 +42,10 @@ void reset_counters_at_start_of_day() // day counter should be increased and daily energy counters reset TEST_ASSERT_EQUAL(1, log_data.day_counter); - TEST_ASSERT_EQUAL(0, solar_terminal.dis_energy_Wh); - TEST_ASSERT_EQUAL(0, bat_terminal.dis_energy_Wh); - TEST_ASSERT_EQUAL(0, bat_terminal.chg_energy_Wh); - TEST_ASSERT_EQUAL(0, load_terminal.chg_energy_Wh); + TEST_ASSERT_EQUAL(0, solar_terminal.neg_energy_Wh); + TEST_ASSERT_EQUAL(0, bat_terminal.neg_energy_Wh); + TEST_ASSERT_EQUAL(0, bat_terminal.pos_energy_Wh); + TEST_ASSERT_EQUAL(0, load_terminal.pos_energy_Wh); } void log_new_solar_voltage_max() diff --git a/test/tests_power_port.cpp b/test/tests_power_port.cpp index a5a68ad..9e55c01 100644 --- a/test/tests_power_port.cpp +++ b/test/tests_power_port.cpp @@ -29,10 +29,10 @@ void energy_calculation_init() log_data.load_out_total_Wh = 0; log_data.bat_chg_total_Wh = 0; log_data.bat_dis_total_Wh = 0; - hv_terminal.dis_energy_Wh = 0.0; - load_terminal.chg_energy_Wh = 0.0; - lv_terminal.chg_energy_Wh = 0.0; - lv_terminal.dis_energy_Wh = 0.0; + hv_terminal.neg_energy_Wh = 0.0; + load_terminal.pos_energy_Wh = 0.0; + lv_terminal.pos_energy_Wh = 0.0; + lv_terminal.neg_energy_Wh = 0.0; // set desired measurement values adcval.bat_temperature = 25; @@ -69,26 +69,26 @@ void charging_energy_calculation_valid() { energy_calculation_init(); // charging only during sun hours - TEST_ASSERT_EQUAL_FLOAT(round(sun_hours * lv_terminal.voltage * (dcdc_current_sun - load_current)), round(lv_terminal.chg_energy_Wh)); + TEST_ASSERT_EQUAL_FLOAT(round(sun_hours * lv_terminal.voltage * (dcdc_current_sun - load_current)), round(lv_terminal.pos_energy_Wh)); } void discharging_energy_calculation_valid() { energy_calculation_init(); // discharging (sum of current) only during dis hours - TEST_ASSERT_EQUAL_FLOAT(round(night_hours * lv_terminal.voltage * adcval.load_current), round(lv_terminal.dis_energy_Wh)); + TEST_ASSERT_EQUAL_FLOAT(round(night_hours * lv_terminal.voltage * adcval.load_current), round(lv_terminal.neg_energy_Wh)); } void solar_input_energy_calculation_valid() { energy_calculation_init(); - TEST_ASSERT_EQUAL_FLOAT(round(sun_hours * lv_terminal.voltage * dcdc_current_sun), round(hv_terminal.dis_energy_Wh)); + TEST_ASSERT_EQUAL_FLOAT(round(sun_hours * lv_terminal.voltage * dcdc_current_sun), round(hv_terminal.neg_energy_Wh)); } void load_output_energy_calculation_valid() { energy_calculation_init(); - TEST_ASSERT_EQUAL_FLOAT(round((sun_hours + night_hours) * lv_terminal.voltage * adcval.load_current), round(load_terminal.chg_energy_Wh)); + TEST_ASSERT_EQUAL_FLOAT(round((sun_hours + night_hours) * lv_terminal.voltage * adcval.load_current), round(load_terminal.pos_energy_Wh)); } void pass_voltage_targets_to_adjacent_bus() @@ -96,28 +96,28 @@ void pass_voltage_targets_to_adjacent_bus() // without any droop bat_terminal.current = 0; bat_terminal.pass_voltage_targets(&dcdc_lv_port); - TEST_ASSERT_EQUAL(bat_terminal.chg_voltage_min, dcdc_lv_port.chg_voltage_min); - TEST_ASSERT_EQUAL(bat_terminal.chg_voltage_target, dcdc_lv_port.chg_voltage_target); - TEST_ASSERT_EQUAL(bat_terminal.dis_voltage_start, dcdc_lv_port.dis_voltage_start); - TEST_ASSERT_EQUAL(bat_terminal.dis_voltage_stop, dcdc_lv_port.dis_voltage_stop); + TEST_ASSERT_EQUAL(bat_terminal.sink_voltage_min, dcdc_lv_port.sink_voltage_min); + TEST_ASSERT_EQUAL(bat_terminal.sink_voltage_max, dcdc_lv_port.sink_voltage_max); + TEST_ASSERT_EQUAL(bat_terminal.src_voltage_start, dcdc_lv_port.src_voltage_start); + TEST_ASSERT_EQUAL(bat_terminal.src_voltage_stop, dcdc_lv_port.src_voltage_stop); // now with droop for positive current bat_terminal.current = 11; - bat_terminal.chg_droop_res = 0.1; + bat_terminal.pos_droop_res = 0.1; bat_terminal.pass_voltage_targets(&dcdc_lv_port); - TEST_ASSERT_EQUAL(bat_terminal.chg_voltage_min, dcdc_lv_port.chg_voltage_min); - TEST_ASSERT_EQUAL(bat_terminal.chg_voltage_target + 11*0.1, dcdc_lv_port.chg_voltage_target); - TEST_ASSERT_EQUAL(bat_terminal.dis_voltage_start + 11*0.1, dcdc_lv_port.dis_voltage_start); - TEST_ASSERT_EQUAL(bat_terminal.dis_voltage_stop + 11*0.1, dcdc_lv_port.dis_voltage_stop); + TEST_ASSERT_EQUAL(bat_terminal.sink_voltage_min, dcdc_lv_port.sink_voltage_min); + TEST_ASSERT_EQUAL(bat_terminal.sink_voltage_max + 11*0.1, dcdc_lv_port.sink_voltage_max); + TEST_ASSERT_EQUAL(bat_terminal.src_voltage_start + 11*0.1, dcdc_lv_port.src_voltage_start); + TEST_ASSERT_EQUAL(bat_terminal.src_voltage_stop + 11*0.1, dcdc_lv_port.src_voltage_stop); // now with droop for negative current bat_terminal.current = -11; - bat_terminal.chg_droop_res = 0.1; + bat_terminal.pos_droop_res = 0.1; bat_terminal.pass_voltage_targets(&dcdc_lv_port); - TEST_ASSERT_EQUAL(bat_terminal.chg_voltage_min, dcdc_lv_port.chg_voltage_min); - TEST_ASSERT_EQUAL(bat_terminal.chg_voltage_target - 11*0.1, dcdc_lv_port.chg_voltage_target); - TEST_ASSERT_EQUAL(bat_terminal.dis_voltage_start - 11*0.1, dcdc_lv_port.dis_voltage_start); - TEST_ASSERT_EQUAL(bat_terminal.dis_voltage_stop - 11*0.1, dcdc_lv_port.dis_voltage_stop); + TEST_ASSERT_EQUAL(bat_terminal.sink_voltage_min, dcdc_lv_port.sink_voltage_min); + TEST_ASSERT_EQUAL(bat_terminal.sink_voltage_max - 11*0.1, dcdc_lv_port.sink_voltage_max); + TEST_ASSERT_EQUAL(bat_terminal.src_voltage_start - 11*0.1, dcdc_lv_port.src_voltage_start); + TEST_ASSERT_EQUAL(bat_terminal.src_voltage_stop - 11*0.1, dcdc_lv_port.src_voltage_stop); } void power_port_tests()