PowerPort member variables renamed

Previous naming with chg/dis didn't make much sense e.g. for load output or solar panels. Voltage
targets are now named with source or sink. Current limits are defined based on their direction
(negative or positive). ASCII art graphic added for better explanation of passive sign convention.
This commit is contained in:
Martin Jaeger
2019-10-23 10:32:48 +02:00
parent 515b098e85
commit 42751c83c2
13 changed files with 189 additions and 163 deletions
+3 -3
View File
@@ -256,7 +256,7 @@ void LoadOutput::state_machine()
//printf("Load State: %d\n", switch_state);
switch (switch_state) {
case LOAD_STATE_DISABLED:
if (port->dis_current_limit < 0 // discharging enabled
if (port->neg_current_limit < 0 // discharging enabled
&& enabled_target == true)
{
switch_set(true);
@@ -268,7 +268,7 @@ void LoadOutput::state_machine()
switch_set(false);
switch_state = LOAD_STATE_DISABLED;
}
else if (port->dis_current_limit == 0) { // float == is allowed for 0.0
else if (port->neg_current_limit == 0) { // float == is allowed for 0.0
lvd_timestamp = time(NULL);
switch_set(false);
switch_state = LOAD_STATE_OFF_LOW_SOC;
@@ -276,7 +276,7 @@ void LoadOutput::state_machine()
break;
case LOAD_STATE_OFF_LOW_SOC:
// wait at least one hour
if (port->dis_current_limit < 0 // discharging enabled again
if (port->neg_current_limit < 0 // discharging enabled again
&& time(NULL) - lvd_timestamp > 60*60)
{
if (enabled_target == true) {