PowerPort member variables renamed
Previous naming with chg/dis didn't make much sense e.g. for load output or solar panels. Voltage targets are now named with source or sink. Current limits are defined based on their direction (negative or positive). ASCII art graphic added for better explanation of passive sign convention.
This commit is contained in:
+3
-3
@@ -256,7 +256,7 @@ void LoadOutput::state_machine()
|
||||
//printf("Load State: %d\n", switch_state);
|
||||
switch (switch_state) {
|
||||
case LOAD_STATE_DISABLED:
|
||||
if (port->dis_current_limit < 0 // discharging enabled
|
||||
if (port->neg_current_limit < 0 // discharging enabled
|
||||
&& enabled_target == true)
|
||||
{
|
||||
switch_set(true);
|
||||
@@ -268,7 +268,7 @@ void LoadOutput::state_machine()
|
||||
switch_set(false);
|
||||
switch_state = LOAD_STATE_DISABLED;
|
||||
}
|
||||
else if (port->dis_current_limit == 0) { // float == is allowed for 0.0
|
||||
else if (port->neg_current_limit == 0) { // float == is allowed for 0.0
|
||||
lvd_timestamp = time(NULL);
|
||||
switch_set(false);
|
||||
switch_state = LOAD_STATE_OFF_LOW_SOC;
|
||||
@@ -276,7 +276,7 @@ void LoadOutput::state_machine()
|
||||
break;
|
||||
case LOAD_STATE_OFF_LOW_SOC:
|
||||
// wait at least one hour
|
||||
if (port->dis_current_limit < 0 // discharging enabled again
|
||||
if (port->neg_current_limit < 0 // discharging enabled again
|
||||
&& time(NULL) - lvd_timestamp > 60*60)
|
||||
{
|
||||
if (enabled_target == true) {
|
||||
|
||||
Reference in New Issue