Charger.num_batteries moved to DcBus.series_multiplier

The reason is that the voltage disconnect thresholds used in the load outputs
need to be multiplied with number of batteries aswell. As the DcBus class
should contain all voltage-relevant information, it is the right place for the
multiplier.
This commit is contained in:
Martin Jäger
2020-03-01 09:48:35 +01:00
parent 651f66616b
commit 1a9c290485
9 changed files with 72 additions and 62 deletions
+5 -4
View File
@@ -277,6 +277,9 @@ const data_object_t data_objects[] = {
TS_OUTPUT, TS_READ_ALL),
#endif
TS_DATA_OBJ_INT16(0x8F, "NumBatteries", &lv_bus.series_multiplier,
TS_OUTPUT, TS_READ_ALL),
TS_DATA_OBJ_UINT32(0x90, "ErrorFlags", &dev_stat.error_flags,
TS_OUTPUT, TS_READ_ALL),
@@ -447,10 +450,8 @@ void data_objects_update_conf()
if (battery_conf_check(&bat_conf_user)) {
printf("New config valid and activated.\n");
battery_conf_overwrite(&bat_conf_user, &bat_conf, &charger);
load.set_voltage_limits(
bat_conf.voltage_load_disconnect * charger.num_batteries,
bat_conf.voltage_load_reconnect * charger.num_batteries,
bat_conf.voltage_absolute_max * charger.num_batteries);
load.set_voltage_limits(bat_conf.voltage_load_disconnect, bat_conf.voltage_load_reconnect,
bat_conf.voltage_absolute_max);
changed = true;
}
else {