diff --git a/src/bat_charger.cpp b/src/bat_charger.cpp index 5a9502a..e759e8e 100644 --- a/src/bat_charger.cpp +++ b/src/bat_charger.cpp @@ -243,7 +243,7 @@ void Charger::detect_num_batteries(BatConf *bat) { if (port->bus->voltage > bat->voltage_absolute_min * 2 && port->bus->voltage < bat->voltage_absolute_max * 2) { - num_batteries = 2; + port->bus->series_multiplier = 2; printf("Detected two batteries (total %.2f V max)\n", bat->topping_voltage * 2); } else { @@ -292,8 +292,8 @@ void Charger::discharge_control(BatConf *bat_conf) // load output state is defined by battery negative current limit if (port->neg_current_limit < 0) { // discharging currently allowed. see if that's still valid: - if (port->bus->voltage < num_batteries * - port->bus->src_droop_voltage(bat_conf->voltage_load_disconnect)) + if (port->bus->voltage < + port->bus->src_control_voltage(bat_conf->voltage_load_disconnect)) { uv_debounce_counter++; if (uv_debounce_counter >= 3) { // 3s in undervoltage --> switch off @@ -333,8 +333,7 @@ void Charger::discharge_control(BatConf *bat_conf) } else { // discharging currently not allowed. should we allow it? - if (port->bus->voltage >= num_batteries * - port->bus->src_droop_voltage(bat_conf->voltage_load_reconnect) + if (port->bus->voltage >= port->bus->src_control_voltage(bat_conf->voltage_load_reconnect) && bat_temperature < bat_conf->discharge_temp_max - 1 && bat_temperature > bat_conf->discharge_temp_min + 1) { @@ -365,7 +364,7 @@ void Charger::charge_control(BatConf *bat_conf) } if (dev_stat.has_error(ERR_BAT_OVERVOLTAGE) && - port->bus->voltage < (bat_conf->voltage_absolute_max - 0.5) * num_batteries) + port->bus->voltage < (bat_conf->voltage_absolute_max - 0.5) * port->bus->series_multiplier) { dev_stat.clear_error(ERR_BAT_OVERVOLTAGE); } @@ -373,14 +372,14 @@ void Charger::charge_control(BatConf *bat_conf) // state machine switch (state) { case CHG_STATE_IDLE: { - if (port->bus->voltage < bat_conf->voltage_recharge * num_batteries - && port->bus->voltage > bat_conf->voltage_absolute_min * num_batteries // ToDo set error flag otherwise + if (port->bus->voltage < port->bus->sink_control_voltage(bat_conf->voltage_recharge) + && port->bus->voltage > port->bus->sink_control_voltage(bat_conf->voltage_absolute_min) // ToDo set error flag otherwise && (uptime() - time_state_changed) > bat_conf->time_limit_recharge && bat_temperature < bat_conf->charge_temp_max - 1 && bat_temperature > bat_conf->charge_temp_min + 1) { - port->bus->sink_voltage_bound = num_batteries * (bat_conf->topping_voltage + - bat_conf->temperature_compensation * (bat_temperature - 25)); + port->bus->sink_voltage_bound = bat_conf->topping_voltage + + bat_conf->temperature_compensation * (bat_temperature - 25); port->pos_current_limit = bat_conf->charge_current_max; full = false; dev_stat.clear_error(ERR_BAT_CHG_OVERTEMP); @@ -392,10 +391,10 @@ void Charger::charge_control(BatConf *bat_conf) } case CHG_STATE_BULK: { // continuously adjust voltage setting for temperature compensation - port->bus->sink_voltage_bound = num_batteries * (bat_conf->topping_voltage + - bat_conf->temperature_compensation * (bat_temperature - 25)); + port->bus->sink_voltage_bound = bat_conf->topping_voltage + + bat_conf->temperature_compensation * (bat_temperature - 25); - if (port->bus->voltage > port->bus->sink_droop_voltage()) { + if (port->bus->voltage > port->bus->sink_control_voltage()) { target_voltage_timer = 0; enter_state(CHG_STATE_TOPPING); } @@ -403,10 +402,10 @@ void Charger::charge_control(BatConf *bat_conf) } case CHG_STATE_TOPPING: { // continuously adjust voltage setting for temperature compensation - port->bus->sink_voltage_bound = num_batteries * (bat_conf->topping_voltage + - bat_conf->temperature_compensation * (bat_temperature - 25)); + port->bus->sink_voltage_bound = bat_conf->topping_voltage + + bat_conf->temperature_compensation * (bat_temperature - 25); - if (port->bus->voltage >= port->bus->sink_droop_voltage() - 0.05F) { + if (port->bus->voltage >= port->bus->sink_control_voltage() - 0.05F) { // battery is full if topping target voltage is still reached (i.e. sufficient // solar power available) and time limit or cut-off current reached if (port->current < bat_conf->topping_current_cutoff || @@ -432,13 +431,13 @@ void Charger::charge_control(BatConf *bat_conf) num_deep_discharges - deep_dis_last_equalization >= bat_conf->equalization_trigger_deep_cycles)) { - port->bus->sink_voltage_bound = num_batteries * bat_conf->equalization_voltage; + port->bus->sink_voltage_bound = bat_conf->equalization_voltage; port->pos_current_limit = bat_conf->equalization_current_limit; enter_state(CHG_STATE_EQUALIZATION); } else if (bat_conf->trickle_enabled) { - port->bus->sink_voltage_bound = num_batteries * (bat_conf->trickle_voltage + - bat_conf->temperature_compensation * (bat_temperature - 25)); + port->bus->sink_voltage_bound = bat_conf->trickle_voltage + + bat_conf->temperature_compensation * (bat_temperature - 25); enter_state(CHG_STATE_TRICKLE); } else { @@ -450,10 +449,10 @@ void Charger::charge_control(BatConf *bat_conf) } case CHG_STATE_TRICKLE: { // continuously adjust voltage setting for temperature compensation - port->bus->sink_voltage_bound = num_batteries * (bat_conf->trickle_voltage + - bat_conf->temperature_compensation * (bat_temperature - 25)); + port->bus->sink_voltage_bound = bat_conf->trickle_voltage + + bat_conf->temperature_compensation * (bat_temperature - 25); - if (port->bus->voltage >= port->bus->sink_droop_voltage()) { + if (port->bus->voltage >= port->bus->sink_control_voltage()) { time_target_voltage_reached = uptime(); } @@ -470,8 +469,8 @@ void Charger::charge_control(BatConf *bat_conf) } case CHG_STATE_EQUALIZATION: { // continuously adjust voltage setting for temperature compensation - port->bus->sink_voltage_bound = num_batteries * (bat_conf->equalization_voltage + - bat_conf->temperature_compensation * (bat_temperature - 25)); + port->bus->sink_voltage_bound = bat_conf->equalization_voltage + + bat_conf->temperature_compensation * (bat_temperature - 25); // current or time limit for equalization reached if (uptime() - time_state_changed > bat_conf->equalization_duration) @@ -483,8 +482,8 @@ void Charger::charge_control(BatConf *bat_conf) discharged_Ah = 0; // reset coulomb counter again if (bat_conf->trickle_enabled) { - port->bus->sink_voltage_bound = num_batteries * (bat_conf->trickle_voltage + - bat_conf->temperature_compensation * (bat_temperature - 25)); + port->bus->sink_voltage_bound = bat_conf->trickle_voltage + + bat_conf->temperature_compensation * (bat_temperature - 25); enter_state(CHG_STATE_TRICKLE); } else { @@ -499,16 +498,24 @@ void Charger::charge_control(BatConf *bat_conf) void Charger::init_terminal(BatConf *bat) { - port->bus->sink_voltage_bound = bat->topping_voltage * num_batteries; - port->bus->src_voltage_bound = bat->voltage_load_disconnect * num_batteries; + port->bus->sink_voltage_bound = bat->topping_voltage; + port->bus->src_voltage_bound = bat->voltage_load_disconnect; port->neg_current_limit = -bat->discharge_current_max; port->pos_current_limit = bat->charge_current_max; - // negative sign for compensation of actual resistance - port->bus->sink_droop_res = -bat->wire_resistance; + /* + * Negative sign for compensation of actual resistance + * + * droop_res is multiplied with number of series connected batteries to calculate control + * voltage, so we need to divide by number of batteries here for correction + */ + port->bus->sink_droop_res = -bat->wire_resistance / port->bus->series_multiplier; - // in discharging direction also include battery internal resistance for current-compensation - // of voltage setpoints - port->bus->src_droop_res = -bat->wire_resistance - bat->internal_resistance * num_batteries; + /* + * In discharging direction also include battery internal resistance for current-compensation + * of voltage setpoints + */ + port->bus->src_droop_res = -bat->wire_resistance / port->bus->series_multiplier + - bat->internal_resistance; } diff --git a/src/bat_charger.h b/src/bat_charger.h index 40290de..b339ad2 100644 --- a/src/bat_charger.h +++ b/src/bat_charger.h @@ -18,7 +18,6 @@ #include #include "power_port.h" -#include "load.h" /** Battery cell types */ @@ -234,9 +233,6 @@ public: uint32_t state; ///< Current charger state (see enum ChargerState) - int32_t num_batteries = 1; ///< Used for automatic 12V/24V battery detection at - ///< start-up (can be 1 or 2 only) - float bat_temperature = 25; ///< Battery temperature in °C from ext. temperature sensor ///< (if existing) bool ext_temp_sensor; ///< True if external temperature sensor was detected diff --git a/src/data_objects.cpp b/src/data_objects.cpp index 69f0c76..6e93ce9 100644 --- a/src/data_objects.cpp +++ b/src/data_objects.cpp @@ -277,6 +277,9 @@ const data_object_t data_objects[] = { TS_OUTPUT, TS_READ_ALL), #endif + TS_DATA_OBJ_INT16(0x8F, "NumBatteries", &lv_bus.series_multiplier, + TS_OUTPUT, TS_READ_ALL), + TS_DATA_OBJ_UINT32(0x90, "ErrorFlags", &dev_stat.error_flags, TS_OUTPUT, TS_READ_ALL), @@ -447,10 +450,8 @@ void data_objects_update_conf() if (battery_conf_check(&bat_conf_user)) { printf("New config valid and activated.\n"); battery_conf_overwrite(&bat_conf_user, &bat_conf, &charger); - load.set_voltage_limits( - bat_conf.voltage_load_disconnect * charger.num_batteries, - bat_conf.voltage_load_reconnect * charger.num_batteries, - bat_conf.voltage_absolute_max * charger.num_batteries); + load.set_voltage_limits(bat_conf.voltage_load_disconnect, bat_conf.voltage_load_reconnect, + bat_conf.voltage_absolute_max); changed = true; } else { diff --git a/src/dcdc.cpp b/src/dcdc.cpp index 1a18ac4..e8061e0 100644 --- a/src/dcdc.cpp +++ b/src/dcdc.cpp @@ -78,7 +78,7 @@ int Dcdc::duty_cycle_delta() // swith off after 10s low power or negative power (if not in nanogrid mode) pwr_inc_goal = 0; } - else if (out->bus->voltage > out->bus->sink_droop_voltage()) { + else if (out->bus->voltage > out->bus->sink_control_voltage()) { // output voltage target reached state = DCDC_STATE_CV; pwr_inc_goal = -1; // decrease output power @@ -90,7 +90,7 @@ int Dcdc::duty_cycle_delta() } else if (fabs(lvs->current) > ls_current_max // current above hardware maximum || temp_mosfets > 80 // temperature limits exceeded - || (in->bus->voltage < in->bus->src_droop_voltage() + || (in->bus->voltage < in->bus->src_control_voltage() && out->current > 0.1) // input voltage below limit || in->current < in->neg_current_limit) // input current (negative signs) limit exceeded { diff --git a/src/load.cpp b/src/load.cpp index 260ca91..373c9dd 100644 --- a/src/load.cpp +++ b/src/load.cpp @@ -56,7 +56,7 @@ void LoadOutput::control() flags_set(&error_flags, ERR_LOAD_BUS_SRC_CURRENT); } - if (bus->voltage < bus->src_droop_voltage(disconnect_voltage)) { + if (bus->voltage < bus->src_control_voltage(disconnect_voltage)) { flags_set(&error_flags, ERR_LOAD_SHEDDING); lvd_timestamp = uptime(); } @@ -86,7 +86,7 @@ void LoadOutput::control() // load is off: check if errors are resolved and if load can be switched on if (flags_check(&error_flags, ERR_LOAD_SHEDDING) && - bus->voltage > bus->src_droop_voltage(reconnect_voltage) && + bus->voltage > bus->src_control_voltage(reconnect_voltage) && uptime() - lvd_timestamp > lvd_recovery_delay) { flags_clear(&error_flags, ERR_LOAD_SHEDDING); diff --git a/src/main_mbed.cpp b/src/main_mbed.cpp index b72f691..8bc6584 100644 --- a/src/main_mbed.cpp +++ b/src/main_mbed.cpp @@ -72,10 +72,8 @@ int main() charger.detect_num_batteries(&bat_conf); // check if we have 24V instead of 12V system charger.init_terminal(&bat_conf); - load.set_voltage_limits( - bat_conf.voltage_load_disconnect * charger.num_batteries, - bat_conf.voltage_load_reconnect * charger.num_batteries, - bat_conf.voltage_absolute_max * charger.num_batteries); + load.set_voltage_limits(bat_conf.voltage_load_disconnect, bat_conf.voltage_load_reconnect, + bat_conf.voltage_absolute_max); wait(2); // safety feature: be able to re-flash before starting control_timer_start(CONTROL_FREQUENCY); diff --git a/src/main_zephyr.cpp b/src/main_zephyr.cpp index 28ff6ef..797fba5 100644 --- a/src/main_zephyr.cpp +++ b/src/main_zephyr.cpp @@ -64,10 +64,8 @@ void main(void) charger.detect_num_batteries(&bat_conf); // check if we have 24V instead of 12V system charger.init_terminal(&bat_conf); - load.set_voltage_limits( - bat_conf.voltage_load_disconnect * charger.num_batteries, - bat_conf.voltage_load_reconnect * charger.num_batteries, - bat_conf.voltage_absolute_max * charger.num_batteries); + load.set_voltage_limits(bat_conf.voltage_load_disconnect, bat_conf.voltage_load_reconnect, + bat_conf.voltage_absolute_max); k_sleep(2000); // safety feature: be able to re-flash before starting diff --git a/src/power_port.h b/src/power_port.h index a4e3a4f..a022f39 100644 --- a/src/power_port.h +++ b/src/power_port.h @@ -12,6 +12,7 @@ * @brief Definition of charge controller terminals and internal DC buses */ +#include #include class PowerPort; // forward-declaration @@ -29,6 +30,15 @@ public: */ float voltage; + /** + * Multiplier for series connection of batteries + * + * Used for automatic 12V/24V battery detection at start-up (can be 1 or 2 only) + * + * This factur must be applied to all voltage setpoints + */ + int16_t series_multiplier = 1; + /** * Upper voltage boundary where this bus may be used to sink current. * @@ -78,36 +88,36 @@ public: float src_current_margin; /** - * Calculate current-compensated voltage based on bus reference current + * Calculate current-compensated src control voltage, considering droop and series multiplier * * @param voltage_zero_current Voltage at zero current (without droop). If this parameter is * left empty, the src_voltage_bound is considered. */ - inline float src_droop_voltage(float voltage_zero_current = 0) + inline float src_control_voltage(float voltage_zero_current = 0) { float v0 = (voltage_zero_current == 0) ? src_voltage_bound : voltage_zero_current; if (ref_current != nullptr) { - return v0 - src_droop_res * (*ref_current); + return (v0 - src_droop_res * (*ref_current)) * series_multiplier; } else { - return v0; + return v0 * series_multiplier; } } /** - * Calculate current-compensated voltage based on bus reference current + * Calculate current-compensated sink control voltage, considering droop and series multiplier * * @param voltage_zero_current Voltage at zero current (without droop). If this parameter is * left empty, the sink_voltage_bound is considered. */ - inline float sink_droop_voltage(float voltage_zero_current = 0) + inline float sink_control_voltage(float voltage_zero_current = 0) { float v0 = (voltage_zero_current == 0) ? sink_voltage_bound : voltage_zero_current; if (ref_current != nullptr) { - return v0 - sink_droop_res * (*ref_current); + return (v0 - sink_droop_res * (*ref_current)) * series_multiplier; } else { - return v0; + return v0 * series_multiplier; } } }; diff --git a/src/pwm_switch.cpp b/src/pwm_switch.cpp index 2361cb5..e49812f 100644 --- a/src/pwm_switch.cpp +++ b/src/pwm_switch.cpp @@ -179,7 +179,7 @@ void PwmSwitch::control() off_timestamp = uptime(); print_info("PWM charger stop.\n"); } - else if (bus->voltage > bus->sink_droop_voltage() // bus voltage above target + else if (bus->voltage > bus->sink_control_voltage() // bus voltage above target || current < neg_current_limit // port current limit exceeded || current < -PWM_CURRENT_MAX) // PCB current limit exceeded {