72 lines
2.9 KiB
C
72 lines
2.9 KiB
C
/* LibreSolar charge controller firmware
|
|
* Copyright (c) 2016-2019 Martin Jäger (www.libre.solar)
|
|
*
|
|
* Licensed under the Apache License, Version 2.0 (the "License");
|
|
* you may not use this file except in compliance with the License.
|
|
* You may obtain a copy of the License at
|
|
*
|
|
* http://www.apache.org/licenses/LICENSE-2.0
|
|
*
|
|
* Unless required by applicable law or agreed to in writing, software
|
|
* distributed under the License is distributed on an "AS IS" BASIS,
|
|
* WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
|
|
* See the License for the specific language governing permissions and
|
|
* limitations under the License.
|
|
*/
|
|
|
|
#ifndef DC_BUS_H
|
|
#define DC_BUS_H
|
|
|
|
/** @file
|
|
*
|
|
* @brief Definition of power ports of a DC/DC converter (high-side or low-side terminal)
|
|
*/
|
|
|
|
#include <stdbool.h>
|
|
|
|
/** DC bus type
|
|
*
|
|
* Saves current target settings of either high-side or low-side port of a
|
|
* DC/DC converter. In this way, e.g. a battery can be configured to be
|
|
* connected to high or low side of DC/DC converter w/o having to rewrite
|
|
* the control algorithm.
|
|
*/
|
|
typedef struct {
|
|
float voltage; ///< measured voltage
|
|
float current; ///< sum of currents (positive sign = increasing voltage/charge of the bus)
|
|
|
|
bool chg_allowed; ///< charging direction for battery port
|
|
float chg_voltage_target; ///< target voltage if port is configured as output
|
|
float chg_droop_res; ///< v_target = v_out_max - r_droop_output * current
|
|
float chg_voltage_min; ///< minimum voltage to allow current output (necessary
|
|
///< to prevent charging of deep-discharged Li-ion batteries)
|
|
float chg_current_max; ///< charging direction for battery port
|
|
|
|
bool dis_allowed; ///< discharging direction for battery port
|
|
float dis_voltage_start; ///< minimum voltage to allow current input (= discharging of batteries),
|
|
///< starting point for discharging of batteries (load reconnect)
|
|
float dis_voltage_stop; ///< absolute minimum = load disconnect for batteries
|
|
float dis_droop_res; ///< v_stop = v_input_stop - r_droop_input * current
|
|
float dis_current_max; ///< discharging direction for battery port: must be negative value !!!
|
|
|
|
float chg_energy_Wh; ///< cumulated energy in charge direction since last counter reset (Wh)
|
|
float dis_energy_Wh; ///< cumulated energy in discharge direction since last counter reset (Wh)
|
|
|
|
} dc_bus_t;
|
|
|
|
/** Initialize dc bus for solar panel connection
|
|
*/
|
|
void dc_bus_init_solar(dc_bus_t *bus);
|
|
|
|
/** Initialize dc bus for nanogrid connection
|
|
*/
|
|
void dc_bus_init_nanogrid(dc_bus_t *bus);
|
|
|
|
/** Energy balance calculation for dc bus
|
|
*
|
|
* Must be called exactly once per second, otherwise energy calculation gets wrong.
|
|
*/
|
|
void dc_bus_energy_balance(dc_bus_t *bus);
|
|
|
|