Files
charge-controller-firmware/test/tests_bat_charger.cpp
T
Martin Jaeger 68e0336279 Add debounce counter for UV error detection
This prevents switching off the load output due to short undervoltage
events during startup of pumps etc. when the battery is at low SOC.
2020-02-19 14:34:40 +01:00

333 lines
10 KiB
C++

/*
* Copyright (c) 2018 Martin Jäger / Libre Solar
*
* SPDX-License-Identifier: Apache-2.0
*/
#include "tests.h"
#include <time.h>
#include <stdio.h>
#include "setup.h"
static void init_structs()
{
battery_conf_init(&bat_conf, BAT_TYPE_FLOODED, 6, 100);
battery_init_terminal(&bat_terminal, &bat_conf, 1);
charger.state = CHG_STATE_IDLE;
charger.bat_temperature = 25;
bat_terminal.bus->voltage = 14.0;
bat_terminal.current = 0;
}
void no_start_at_high_voltage()
{
init_structs();
bat_terminal.bus->voltage = bat_conf.voltage_recharge + 0.1;
charger.charge_control(&bat_conf);
TEST_ASSERT_EQUAL(CHG_STATE_IDLE, charger.state);
}
void no_start_after_short_rest()
{
init_structs();
charger.time_state_changed = time(NULL) - bat_conf.time_limit_recharge + 1;
bat_terminal.bus->voltage = bat_conf.voltage_recharge - 0.1;
charger.charge_control(&bat_conf);
TEST_ASSERT_EQUAL(CHG_STATE_IDLE, charger.state);
}
void no_start_outside_temperature_limits()
{
init_structs();
charger.bat_temperature = bat_conf.charge_temp_max + 1;
bat_terminal.bus->voltage = bat_conf.voltage_recharge - 0.1;
charger.charge_control(&bat_conf);
TEST_ASSERT_EQUAL(CHG_STATE_IDLE, charger.state);
charger.bat_temperature = bat_conf.charge_temp_min - 1;
charger.charge_control(&bat_conf);
TEST_ASSERT_EQUAL(CHG_STATE_IDLE, charger.state);
}
void start_if_everything_just_fine()
{
init_structs();
charger.time_state_changed = time(NULL) - bat_conf.time_limit_recharge - 1;
bat_terminal.bus->voltage = bat_conf.voltage_recharge - 0.1;
charger.charge_control(&bat_conf);
TEST_ASSERT_EQUAL(CHG_STATE_BULK, charger.state);
}
void enter_topping_at_voltage_setpoint()
{
init_structs();
charger.time_state_changed = time(NULL) - bat_conf.time_limit_recharge - 1;
bat_terminal.bus->voltage = bat_conf.voltage_recharge - 0.1;
charger.charge_control(&bat_conf);
TEST_ASSERT_EQUAL(CHG_STATE_BULK, charger.state);
bat_terminal.bus->voltage = bat_conf.topping_voltage + 0.1;
charger.charge_control(&bat_conf);
TEST_ASSERT_EQUAL(CHG_STATE_TOPPING, charger.state);
}
void topping_to_bulk_after_8h_low_power()
{
enter_topping_at_voltage_setpoint();
charger.time_state_changed = time(NULL) - 8 * 60 * 60 + 1;
bat_terminal.bus->voltage = bat_conf.topping_voltage - 0.1;
bat_terminal.current = bat_conf.topping_current_cutoff + 0.1;
charger.charge_control(&bat_conf);
TEST_ASSERT_EQUAL(CHG_STATE_TOPPING, charger.state);
charger.time_state_changed = time(NULL) - 8 * 60 * 60 - 1;
charger.charge_control(&bat_conf);
TEST_ASSERT_EQUAL(CHG_STATE_BULK, charger.state);
}
void stop_topping_after_time_limit()
{
enter_topping_at_voltage_setpoint();
charger.target_voltage_timer = bat_conf.topping_duration - 1;
bat_terminal.bus->voltage = bat_conf.topping_voltage + 0.1;
bat_terminal.current = bat_conf.topping_current_cutoff + 0.1;
charger.charge_control(&bat_conf);
TEST_ASSERT_EQUAL(CHG_STATE_TOPPING, charger.state);
charger.target_voltage_timer = bat_conf.topping_duration + 1;
charger.charge_control(&bat_conf);
TEST_ASSERT_EQUAL(CHG_STATE_TRICKLE, charger.state);
}
void stop_topping_at_cutoff_current()
{
enter_topping_at_voltage_setpoint();
charger.target_voltage_timer = 0;
bat_terminal.bus->voltage = bat_conf.topping_voltage + 0.1;
bat_terminal.current = bat_conf.topping_current_cutoff - 0.1;
charger.charge_control(&bat_conf);
TEST_ASSERT_EQUAL(CHG_STATE_TRICKLE, charger.state);
}
void trickle_to_idle_for_li_ion()
{
enter_topping_at_voltage_setpoint();
battery_conf_init(&bat_conf, BAT_TYPE_LFP, 4, 100);
charger.time_state_changed = time(NULL) - 1;
bat_terminal.bus->voltage = bat_conf.topping_voltage + 0.1;
bat_terminal.current = bat_conf.topping_current_cutoff - 0.1;
charger.charge_control(&bat_conf);
TEST_ASSERT_EQUAL(CHG_STATE_IDLE, charger.state);
}
void no_equalization_if_disabled()
{
enter_topping_at_voltage_setpoint();
bat_conf.equalization_enabled = false;
// set triggers such that it would normally start
charger.deep_dis_last_equalization =
charger.num_deep_discharges - bat_conf.equalization_trigger_deep_cycles;
charger.time_last_equalization =
time(NULL) - bat_conf.equalization_trigger_days * 24*60*60;
charger.time_state_changed = time(NULL) - 1;
bat_terminal.bus->voltage = bat_conf.topping_voltage + 0.1;
bat_terminal.current = bat_conf.topping_current_cutoff - 0.1;
charger.charge_control(&bat_conf);
TEST_ASSERT_NOT_EQUAL(CHG_STATE_EQUALIZATION, charger.state);
}
void no_equalization_if_limits_not_reached()
{
enter_topping_at_voltage_setpoint();
bat_conf.equalization_enabled = true;
// set triggers such that they are just NOT reached
charger.deep_dis_last_equalization =
charger.num_deep_discharges - bat_conf.equalization_trigger_deep_cycles + 1;
charger.time_last_equalization =
time(NULL) - (bat_conf.equalization_trigger_days - 1) * 24*60*60;
charger.time_state_changed = time(NULL) - 1;
bat_terminal.bus->voltage = bat_conf.topping_voltage + 0.1;
bat_terminal.current = bat_conf.topping_current_cutoff - 0.1;
charger.charge_control(&bat_conf);
TEST_ASSERT_NOT_EQUAL(CHG_STATE_EQUALIZATION, charger.state);
}
void trickle_to_equalization_if_enabled_and_time_limit_reached()
{
enter_topping_at_voltage_setpoint();
bat_conf.equalization_enabled = true;
charger.time_last_equalization =
time(NULL) - bat_conf.equalization_trigger_days * 24*60*60;
charger.time_state_changed = time(NULL) - 1;
bat_terminal.bus->voltage = bat_conf.topping_voltage + 0.1;
bat_terminal.current = bat_conf.topping_current_cutoff - 0.1;
charger.charge_control(&bat_conf);
TEST_ASSERT_EQUAL(CHG_STATE_EQUALIZATION, charger.state);
}
void trickle_to_equalization_if_enabled_and_deep_dis_limit_reached()
{
enter_topping_at_voltage_setpoint();
bat_conf.equalization_enabled = true;
charger.deep_dis_last_equalization =
charger.num_deep_discharges - bat_conf.equalization_trigger_deep_cycles;
charger.time_state_changed = time(NULL) - 1;
bat_terminal.bus->voltage = bat_conf.topping_voltage + 0.1;
bat_terminal.current = bat_conf.topping_current_cutoff - 0.1;
charger.charge_control(&bat_conf);
TEST_ASSERT_EQUAL(CHG_STATE_EQUALIZATION, charger.state);
}
void stop_equalization_after_time_limit()
{
trickle_to_equalization_if_enabled_and_time_limit_reached();
charger.time_state_changed = time(NULL) - bat_conf.equalization_duration + 1;
bat_terminal.bus->voltage = bat_conf.equalization_voltage + 0.1;
charger.charge_control(&bat_conf);
TEST_ASSERT_EQUAL(CHG_STATE_EQUALIZATION, charger.state);
charger.time_state_changed = time(NULL) - bat_conf.topping_duration - 1;
charger.charge_control(&bat_conf);
TEST_ASSERT_EQUAL(CHG_STATE_TRICKLE, charger.state);
}
void restart_bulk_from_trickle_if_voltage_drops()
{
TEST_ASSERT(0);
}
void stop_discharge_at_low_voltage()
{
init_structs();
bat_terminal.bus->voltage = 14;
charger.discharge_control(&bat_conf);
TEST_ASSERT_LESS_THAN(0, bat_terminal.neg_current_limit);
bat_terminal.bus->voltage = bat_conf.voltage_load_disconnect - 0.1;
charger.discharge_control(&bat_conf);
charger.discharge_control(&bat_conf); // 2s: still on
TEST_ASSERT_NOT_EQUAL(0, bat_terminal.neg_current_limit);
charger.discharge_control(&bat_conf); // 3s: off
TEST_ASSERT_EQUAL(0, bat_terminal.neg_current_limit);
}
void stop_discharge_at_overtemp()
{
init_structs();
TEST_ASSERT_LESS_THAN(0, bat_terminal.neg_current_limit);
charger.bat_temperature = bat_conf.discharge_temp_max + 1;
charger.discharge_control(&bat_conf);
TEST_ASSERT_EQUAL(0, bat_terminal.neg_current_limit);
}
void stop_discharge_at_undertemp()
{
init_structs();
TEST_ASSERT_LESS_THAN(0, bat_terminal.neg_current_limit);
charger.bat_temperature = bat_conf.discharge_temp_min - 1;
charger.discharge_control(&bat_conf);
TEST_ASSERT_EQUAL(0, bat_terminal.neg_current_limit);
}
void restart_discharge_if_allowed()
{
init_structs();
// stop because of undervoltage
bat_terminal.bus->voltage = bat_conf.voltage_load_disconnect - 0.1;
charger.discharge_control(&bat_conf);
charger.discharge_control(&bat_conf);
charger.discharge_control(&bat_conf); // 3s debounce
TEST_ASSERT_EQUAL(0, bat_terminal.neg_current_limit);
// increase voltage slightly above DISconnect voltage
bat_terminal.bus->voltage = bat_conf.voltage_load_disconnect + 0.1;
charger.discharge_control(&bat_conf);
TEST_ASSERT_EQUAL(0, bat_terminal.neg_current_limit);
// increase voltage above REconnect voltage
bat_terminal.bus->voltage = bat_conf.voltage_load_reconnect + 0.1;
charger.discharge_control(&bat_conf);
TEST_ASSERT_LESS_THAN(0, bat_terminal.neg_current_limit);
}
void battery_values_propagated_to_lv_bus_int()
{
TEST_ASSERT(0);
}
void no_soc_above_100()
{
TEST_ASSERT(0);
}
void no_soc_below_0()
{
TEST_ASSERT(0);
}
void bat_charger_tests()
{
UNITY_BEGIN();
// startup of charging
RUN_TEST(no_start_at_high_voltage);
RUN_TEST(no_start_after_short_rest);
RUN_TEST(no_start_outside_temperature_limits);
RUN_TEST(start_if_everything_just_fine);
// topping
RUN_TEST(enter_topping_at_voltage_setpoint);
RUN_TEST(topping_to_bulk_after_8h_low_power);
RUN_TEST(stop_topping_after_time_limit);
RUN_TEST(stop_topping_at_cutoff_current);
// trickle
RUN_TEST(trickle_to_idle_for_li_ion);
// equalization
RUN_TEST(no_equalization_if_disabled);
RUN_TEST(no_equalization_if_limits_not_reached);
RUN_TEST(trickle_to_equalization_if_enabled_and_time_limit_reached);
RUN_TEST(trickle_to_equalization_if_enabled_and_deep_dis_limit_reached);
RUN_TEST(stop_equalization_after_time_limit);
//RUN_TEST(restart_bulk_from_trickle_if_voltage_drops);
// TODO: temperature compensation
// TODO: current compensation
RUN_TEST(stop_discharge_at_low_voltage);
RUN_TEST(stop_discharge_at_overtemp);
RUN_TEST(stop_discharge_at_undertemp);
RUN_TEST(restart_discharge_if_allowed);
//RUN_TEST(battery_values_propagated_to_lv_bus_int);
// ToDo: SOC calculation
//RUN_TEST(no_soc_above_100);
//RUN_TEST(no_soc_below_0);
UNITY_END();
}