Files
charge-controller-firmware/tests/app/src/tests_bat_charger.cpp
T
Martin JägerandClaude Opus 5.5 a1fff4ee6f tests: app: migrate unit tests from Unity to ztest
Convert the application unit tests to ztest, so that all tests can be
run with twister and the Unity module is not required anymore.

Each test file becomes a ztest suite. The test names got the prefix
test_ as required by twister. Unity assertions were converted as
follows:

- TEST_ASSERT_EQUAL_FLOAT is replaced by assert_float_equal, which uses
  the same relative precision of 1e-5 as Unity.
- TEST_ASSERT_EQUAL and other integer assertions are replaced by their
  ztest equivalents. Unity compared these as integers, so float values
  were truncated before. All tests still pass with exact comparison.

In contrast to Unity, ztest runs the tests of a suite in alphabetical
order. The setup code for the DAQ tests is moved into a before function
and the half bridge is stopped before each buck converter test (same as
for the boost converter tests), as the buck tests previously relied on
running before the boost tests.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-21 13:40:14 +02:00

306 lines
10 KiB
C++

/*
* Copyright (c) The Libre Solar Project Contributors
*
* SPDX-License-Identifier: Apache-2.0
*/
#include "tests.h"
#include <stdio.h>
#include <time.h>
#include "setup.h"
static void init_structs()
{
battery_conf_init(&bat_conf, BAT_TYPE_FLOODED, 6, 100);
charger.init_terminal(&bat_conf);
charger.state = CHG_STATE_IDLE;
charger.bat_temperature = 25;
bat_terminal.bus->voltage = 14.0;
bat_terminal.bus->voltage_filtered = 14.0;
bat_terminal.current = 0;
}
ZTEST(bat_charger, test_no_start_at_high_voltage)
{
init_structs();
bat_terminal.bus->voltage = bat_conf.recharge_voltage + 0.1f;
charger.charge_control(&bat_conf);
zassert_equal(charger.state, CHG_STATE_IDLE);
}
ZTEST(bat_charger, test_no_start_after_short_rest)
{
init_structs();
charger.time_state_changed = time(NULL) - bat_conf.time_limit_recharge + 1;
bat_terminal.bus->voltage = bat_conf.recharge_voltage - 0.1f;
charger.charge_control(&bat_conf);
zassert_equal(charger.state, CHG_STATE_IDLE);
}
ZTEST(bat_charger, test_no_start_outside_temperature_limits)
{
init_structs();
charger.bat_temperature = bat_conf.charge_temp_max + 1;
bat_terminal.bus->voltage = bat_conf.recharge_voltage - 0.1f;
charger.charge_control(&bat_conf);
zassert_equal(charger.state, CHG_STATE_IDLE);
charger.bat_temperature = bat_conf.charge_temp_min - 1;
charger.charge_control(&bat_conf);
zassert_equal(charger.state, CHG_STATE_IDLE);
}
ZTEST(bat_charger, test_start_if_everything_just_fine)
{
init_structs();
charger.time_state_changed = time(NULL) - bat_conf.time_limit_recharge - 1;
bat_terminal.bus->voltage = bat_conf.recharge_voltage - 0.1f;
charger.charge_control(&bat_conf);
zassert_equal(charger.state, CHG_STATE_BULK);
}
static void enter_topping_at_voltage_setpoint()
{
init_structs();
charger.time_state_changed = time(NULL) - bat_conf.time_limit_recharge - 1;
bat_terminal.bus->voltage = bat_conf.recharge_voltage - 0.1f;
bat_terminal.bus->voltage_filtered = bat_terminal.bus->voltage;
charger.charge_control(&bat_conf);
zassert_equal(charger.state, CHG_STATE_BULK);
bat_terminal.bus->voltage = bat_conf.topping_voltage + 0.1f;
bat_terminal.bus->voltage_filtered = bat_terminal.bus->voltage;
charger.charge_control(&bat_conf);
zassert_equal(charger.state, CHG_STATE_TOPPING);
}
ZTEST(bat_charger, test_topping_to_bulk_after_8h_low_power)
{
enter_topping_at_voltage_setpoint();
charger.time_state_changed = time(NULL) - 8 * 60 * 60 + 1;
bat_terminal.bus->voltage = bat_conf.topping_voltage - 0.1f;
bat_terminal.bus->voltage_filtered = bat_terminal.bus->voltage;
bat_terminal.current = bat_conf.topping_cutoff_current + 0.1f;
bat_terminal.current_filtered = bat_terminal.current;
charger.charge_control(&bat_conf);
zassert_equal(charger.state, CHG_STATE_TOPPING);
charger.time_state_changed = time(NULL) - 8 * 60 * 60 - 1;
charger.charge_control(&bat_conf);
zassert_equal(charger.state, CHG_STATE_BULK);
}
ZTEST(bat_charger, test_stop_topping_after_time_limit)
{
enter_topping_at_voltage_setpoint();
charger.target_voltage_timer = bat_conf.topping_duration - 1;
bat_terminal.current = bat_conf.topping_cutoff_current + 0.1f;
bat_terminal.current_filtered = bat_terminal.current;
bat_terminal.bus->voltage =
bat_conf.topping_voltage - bat_terminal.current * bat_terminal.bus->sink_droop_res + 0.1f;
bat_terminal.bus->voltage_filtered = bat_terminal.bus->voltage;
charger.charge_control(&bat_conf);
zassert_equal(charger.state, CHG_STATE_TOPPING);
charger.target_voltage_timer = bat_conf.topping_duration + 1;
charger.charge_control(&bat_conf);
zassert_equal(charger.state, CHG_STATE_FLOAT);
}
ZTEST(bat_charger, test_stop_topping_at_cutoff_current)
{
enter_topping_at_voltage_setpoint();
charger.target_voltage_timer = 0;
bat_terminal.current = bat_conf.topping_cutoff_current - 0.1f;
bat_terminal.current_filtered = bat_terminal.current;
bat_terminal.bus->voltage =
bat_conf.topping_voltage - bat_terminal.current * bat_terminal.bus->sink_droop_res + 0.1f;
bat_terminal.bus->voltage_filtered = bat_terminal.bus->voltage;
charger.charge_control(&bat_conf);
zassert_equal(charger.state, CHG_STATE_FLOAT);
}
ZTEST(bat_charger, test_float_to_idle_for_li_ion)
{
enter_topping_at_voltage_setpoint();
battery_conf_init(&bat_conf, BAT_TYPE_LFP, 4, 100);
charger.time_state_changed = time(NULL) - 1;
bat_terminal.current = bat_conf.topping_cutoff_current - 0.1f;
bat_terminal.bus->voltage =
bat_conf.topping_voltage - bat_terminal.current * bat_terminal.bus->sink_droop_res + 0.1f;
charger.charge_control(&bat_conf);
zassert_equal(charger.state, CHG_STATE_IDLE);
}
ZTEST(bat_charger, test_no_equalization_if_disabled)
{
enter_topping_at_voltage_setpoint();
bat_conf.equalization_enabled = false;
// set triggers such that it would normally start
charger.deep_dis_last_equalization =
charger.num_deep_discharges - bat_conf.equalization_trigger_deep_cycles;
charger.time_last_equalization = time(NULL) - bat_conf.equalization_trigger_days * 24 * 60 * 60;
charger.time_state_changed = time(NULL) - 1;
bat_terminal.bus->voltage = bat_conf.topping_voltage + 0.1f;
bat_terminal.current = bat_conf.topping_cutoff_current - 0.1f;
charger.charge_control(&bat_conf);
zassert_not_equal(charger.state, CHG_STATE_EQUALIZATION);
}
ZTEST(bat_charger, test_no_equalization_if_limits_not_reached)
{
enter_topping_at_voltage_setpoint();
bat_conf.equalization_enabled = true;
// set triggers such that they are just NOT reached
charger.deep_dis_last_equalization =
charger.num_deep_discharges - bat_conf.equalization_trigger_deep_cycles + 1;
charger.time_last_equalization =
time(NULL) - (bat_conf.equalization_trigger_days - 1) * 24 * 60 * 60;
charger.time_state_changed = time(NULL) - 1;
bat_terminal.bus->voltage = bat_conf.topping_voltage + 0.1f;
bat_terminal.current = bat_conf.topping_cutoff_current - 0.1f;
charger.charge_control(&bat_conf);
zassert_not_equal(charger.state, CHG_STATE_EQUALIZATION);
}
static void float_to_equalization_if_enabled_and_time_limit_reached()
{
enter_topping_at_voltage_setpoint();
bat_conf.equalization_enabled = true;
charger.time_last_equalization = time(NULL) - bat_conf.equalization_trigger_days * 24 * 60 * 60;
charger.time_state_changed = time(NULL) - 1;
bat_terminal.current = bat_conf.topping_cutoff_current - 0.1f;
bat_terminal.bus->voltage =
bat_conf.topping_voltage - bat_terminal.current * bat_terminal.bus->sink_droop_res + 0.1f;
charger.charge_control(&bat_conf);
zassert_equal(charger.state, CHG_STATE_EQUALIZATION);
}
ZTEST(bat_charger, test_float_to_equalization_if_enabled_and_deep_dis_limit_reached)
{
enter_topping_at_voltage_setpoint();
bat_conf.equalization_enabled = true;
charger.deep_dis_last_equalization =
charger.num_deep_discharges - bat_conf.equalization_trigger_deep_cycles;
charger.time_state_changed = time(NULL) - 1;
bat_terminal.current = bat_conf.topping_cutoff_current - 0.1f;
bat_terminal.bus->voltage =
bat_conf.topping_voltage - bat_terminal.current * bat_terminal.bus->sink_droop_res + 0.1f;
charger.charge_control(&bat_conf);
zassert_equal(charger.state, CHG_STATE_EQUALIZATION);
}
ZTEST(bat_charger, test_stop_equalization_after_time_limit)
{
float_to_equalization_if_enabled_and_time_limit_reached();
charger.time_state_changed = time(NULL) - bat_conf.equalization_duration + 1;
bat_terminal.bus->voltage = bat_conf.equalization_voltage
- bat_terminal.current * bat_terminal.bus->sink_droop_res + 0.1f;
charger.charge_control(&bat_conf);
zassert_equal(charger.state, CHG_STATE_EQUALIZATION);
charger.time_state_changed = time(NULL) - bat_conf.topping_duration - 1;
charger.charge_control(&bat_conf);
zassert_equal(charger.state, CHG_STATE_FLOAT);
}
void restart_bulk_from_float_if_voltage_drops()
{
zassert_true(0);
}
ZTEST(bat_charger, test_stop_discharge_at_low_voltage)
{
init_structs();
bat_terminal.bus->voltage = 14;
charger.discharge_control(&bat_conf);
zassert_true(bat_terminal.neg_current_limit < 0);
bat_terminal.bus->voltage = bat_conf.absolute_min_voltage - 0.1f;
charger.discharge_control(&bat_conf);
zassert_equal(bat_terminal.neg_current_limit, 0);
}
ZTEST(bat_charger, test_stop_discharge_at_overtemp)
{
init_structs();
zassert_true(bat_terminal.neg_current_limit < 0);
charger.bat_temperature = bat_conf.discharge_temp_max + 1;
charger.discharge_control(&bat_conf);
zassert_equal(bat_terminal.neg_current_limit, 0);
}
ZTEST(bat_charger, test_stop_discharge_at_undertemp)
{
init_structs();
zassert_true(bat_terminal.neg_current_limit < 0);
charger.bat_temperature = bat_conf.discharge_temp_min - 1;
charger.discharge_control(&bat_conf);
zassert_equal(bat_terminal.neg_current_limit, 0);
}
ZTEST(bat_charger, test_restart_discharge_if_allowed)
{
init_structs();
// stop because of undervoltage
bat_terminal.bus->voltage = bat_conf.absolute_min_voltage - 0.1f;
charger.discharge_control(&bat_conf);
zassert_equal(bat_terminal.neg_current_limit, 0);
// increase voltage slightly above absolute minimum
bat_terminal.bus->voltage = bat_conf.absolute_min_voltage + 0.05f;
charger.discharge_control(&bat_conf);
zassert_equal(bat_terminal.neg_current_limit, 0);
// increase voltage above hysteresis voltage
bat_terminal.bus->voltage = bat_conf.absolute_min_voltage + 0.15f;
charger.discharge_control(&bat_conf);
zassert_true(bat_terminal.neg_current_limit < 0);
}
void battery_values_propagated_to_lv_bus_int()
{
zassert_true(0);
}
void no_soc_above_100()
{
zassert_true(0);
}
void no_soc_below_0()
{
zassert_true(0);
}
ZTEST(bat_charger, test_enter_topping_at_voltage_setpoint)
{
enter_topping_at_voltage_setpoint();
}
ZTEST(bat_charger, test_float_to_equalization_if_enabled_and_time_limit_reached)
{
float_to_equalization_if_enabled_and_time_limit_reached();
}
ZTEST_SUITE(bat_charger, NULL, NULL, NULL, NULL, NULL);