DeviceStatus becomes struct device_status with prefixed functions. The error flag helpers are static inline functions in the header. The implementation stays in C++ for now, as it reads data from objects which are not converted yet. The header doesn't include the headers of these objects anymore. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
691 lines
28 KiB
C++
691 lines
28 KiB
C++
/*
|
|
* Copyright (c) The Libre Solar Project Contributors
|
|
*
|
|
* SPDX-License-Identifier: Apache-2.0
|
|
*/
|
|
|
|
#include "bat_charger.h"
|
|
|
|
#include <zephyr/kernel.h>
|
|
|
|
#include <zephyr/logging/log.h>
|
|
LOG_MODULE_REGISTER(bat_charger, CONFIG_BAT_LOG_LEVEL);
|
|
|
|
#include <functional>
|
|
#include <math.h> // for fabs function
|
|
#include <stdio.h>
|
|
|
|
#include "board.h"
|
|
#include "device_status.h"
|
|
#include "helper.h"
|
|
#include "load.h"
|
|
|
|
extern struct device_status dev_stat;
|
|
extern LoadOutput load;
|
|
|
|
// DISCHARGE_CURRENT_MAX used to estimate current-compensation of load disconnect voltage
|
|
#if BOARD_HAS_LOAD_OUTPUT
|
|
#define DISCHARGE_CURRENT_MAX DT_PROP(LOAD_SWITCH_NODE, current_max)
|
|
#else
|
|
#define DISCHARGE_CURRENT_MAX DT_PROP(DT_PATH(pcb), dcdc_current_max)
|
|
#endif
|
|
|
|
void battery_conf_init(BatConf *bat, int type, int num_cells, float nominal_capacity)
|
|
{
|
|
bat->nominal_capacity = nominal_capacity;
|
|
|
|
// 1C should be safe for all batteries
|
|
bat->charge_current_max = bat->nominal_capacity;
|
|
bat->discharge_current_max = bat->nominal_capacity;
|
|
|
|
bat->time_limit_recharge = 60; // sec
|
|
bat->topping_duration = 120 * 60; // sec
|
|
|
|
bat->charge_temp_max = 50;
|
|
bat->charge_temp_min = -10;
|
|
bat->discharge_temp_max = 50;
|
|
bat->discharge_temp_min = -10;
|
|
|
|
switch (type) {
|
|
case BAT_TYPE_FLOODED:
|
|
case BAT_TYPE_AGM:
|
|
case BAT_TYPE_GEL:
|
|
bat->absolute_max_voltage = static_cast<float>(num_cells) * 2.45F;
|
|
bat->topping_voltage = static_cast<float>(num_cells) * 2.4F;
|
|
bat->recharge_voltage = static_cast<float>(num_cells) * 2.2F;
|
|
|
|
// Cell-level thresholds based on EN 62509:2011 (both thresholds current-compensated)
|
|
bat->load_disconnect_voltage = static_cast<float>(num_cells) * 1.95F;
|
|
bat->load_reconnect_voltage = static_cast<float>(num_cells) * 2.10F;
|
|
|
|
// assumption: Battery selection matching charge controller
|
|
bat->internal_resistance =
|
|
static_cast<float>(num_cells) * (1.95F - 1.80F) / DISCHARGE_CURRENT_MAX;
|
|
|
|
bat->absolute_min_voltage = static_cast<float>(num_cells) * 1.6F;
|
|
|
|
// Voltages during idle (no charging/discharging current)
|
|
bat->ocv_full =
|
|
static_cast<float>(num_cells) * ((type == BAT_TYPE_FLOODED) ? 2.10F : 2.15F);
|
|
bat->ocv_empty = static_cast<float>(num_cells) * 1.90F;
|
|
|
|
// https://batteryuniversity.com/learn/article/charging_the_lead_acid_battery
|
|
bat->topping_cutoff_current = bat->nominal_capacity * 0.04F; // 3-5 % of C/1
|
|
|
|
bat->float_enabled = true;
|
|
bat->float_recharge_time = 30 * 60;
|
|
// Values as suggested in EN 62509:2011
|
|
bat->float_voltage =
|
|
static_cast<float>(num_cells) * ((type == BAT_TYPE_FLOODED) ? 2.35F : 2.3F);
|
|
|
|
// Enable for flooded batteries only, according to
|
|
// https://discoverbattery.com/battery-101/equalizing-flooded-batteries-only
|
|
bat->equalization_enabled = false;
|
|
// Values as suggested in EN 62509:2011
|
|
bat->equalization_voltage =
|
|
static_cast<float>(num_cells) * ((type == BAT_TYPE_FLOODED) ? 2.50F : 2.45F);
|
|
bat->equalization_duration = 60 * 60;
|
|
bat->equalization_current_limit = (1.0F / 7.0F) * bat->nominal_capacity;
|
|
bat->equalization_trigger_days = 60;
|
|
bat->equalization_trigger_deep_cycles = 10;
|
|
|
|
bat->temperature_compensation = -0.003F; // -3 mV/°C/cell
|
|
break;
|
|
|
|
case BAT_TYPE_LFP:
|
|
bat->absolute_max_voltage = static_cast<float>(num_cells) * 3.60F;
|
|
bat->topping_voltage = static_cast<float>(num_cells) * 3.55F; // CV voltage
|
|
bat->recharge_voltage = static_cast<float>(num_cells) * 3.35F;
|
|
|
|
bat->load_disconnect_voltage = static_cast<float>(num_cells) * 3.00F;
|
|
bat->load_reconnect_voltage = static_cast<float>(num_cells) * 3.15F;
|
|
|
|
// 5% voltage drop at max current
|
|
bat->internal_resistance = bat->load_disconnect_voltage * 0.05F / DISCHARGE_CURRENT_MAX;
|
|
bat->absolute_min_voltage = static_cast<float>(num_cells) * 2.0F;
|
|
|
|
// will give really nonlinear SOC calculation because of flat OCV of LFP cells...
|
|
bat->ocv_full = static_cast<float>(num_cells) * 3.4F;
|
|
bat->ocv_empty = static_cast<float>(num_cells) * 3.0F;
|
|
|
|
// C/10 cut-off at end of CV phase by default
|
|
bat->topping_cutoff_current = bat->nominal_capacity / 10;
|
|
|
|
bat->float_enabled = false;
|
|
bat->equalization_enabled = false;
|
|
bat->temperature_compensation = 0;
|
|
bat->charge_temp_min = 0;
|
|
break;
|
|
|
|
case BAT_TYPE_NMC:
|
|
case BAT_TYPE_NMC_HV:
|
|
bat->topping_voltage =
|
|
static_cast<float>(num_cells) * ((type == BAT_TYPE_NMC_HV) ? 4.35F : 4.20F);
|
|
bat->absolute_max_voltage =
|
|
bat->topping_voltage + static_cast<float>(num_cells) * 0.05F;
|
|
bat->recharge_voltage = static_cast<float>(num_cells) * 3.9F;
|
|
|
|
bat->load_disconnect_voltage = static_cast<float>(num_cells) * 3.3F;
|
|
bat->load_reconnect_voltage = static_cast<float>(num_cells) * 3.6F;
|
|
|
|
// 5% voltage drop at max current
|
|
bat->internal_resistance = bat->load_disconnect_voltage * 0.05F / DISCHARGE_CURRENT_MAX;
|
|
|
|
bat->absolute_min_voltage = static_cast<float>(num_cells) * 2.5F;
|
|
|
|
bat->ocv_full = static_cast<float>(num_cells) * 4.0F;
|
|
bat->ocv_empty = static_cast<float>(num_cells) * 3.0F;
|
|
|
|
// C/10 cut-off at end of CV phase by default
|
|
bat->topping_cutoff_current = bat->nominal_capacity / 10;
|
|
|
|
bat->float_enabled = false;
|
|
bat->equalization_enabled = false;
|
|
bat->temperature_compensation = 0;
|
|
bat->charge_temp_min = 0;
|
|
break;
|
|
|
|
case BAT_TYPE_CUSTOM:
|
|
#ifdef CONFIG_BAT_TYPE_CUSTOM
|
|
bat->absolute_max_voltage =
|
|
0.001F * static_cast<float>(CONFIG_BAT_NUM_CELLS * CONFIG_CELL_ABS_MAX_VOLTAGE_MV);
|
|
|
|
bat->topping_voltage =
|
|
0.001F * static_cast<float>(CONFIG_BAT_NUM_CELLS * CONFIG_CELL_TOPPING_VOLTAGE_MV);
|
|
|
|
bat->recharge_voltage =
|
|
0.001F * static_cast<float>(CONFIG_BAT_NUM_CELLS * CONFIG_CELL_RECHARGE_VOLTAGE_MV);
|
|
|
|
bat->load_disconnect_voltage =
|
|
0.001F
|
|
* static_cast<float>(CONFIG_BAT_NUM_CELLS * CONFIG_CELL_DISCONNECT_VOLTAGE_MV);
|
|
bat->load_reconnect_voltage =
|
|
0.001F
|
|
* static_cast<float>(CONFIG_BAT_NUM_CELLS * CONFIG_CELL_RECONNECT_VOLTAGE_MV);
|
|
|
|
bat->internal_resistance =
|
|
0.001F
|
|
* static_cast<float>(CONFIG_BAT_NUM_CELLS * CONFIG_CELL_INTERNAL_RESISTANCE_MOHM);
|
|
|
|
bat->absolute_min_voltage =
|
|
0.001F * static_cast<float>(CONFIG_BAT_NUM_CELLS * CONFIG_CELL_ABS_MIN_VOLTAGE_MV);
|
|
|
|
// Voltages during idle (no charging/discharging current)
|
|
bat->ocv_full =
|
|
0.001F * static_cast<float>(CONFIG_BAT_NUM_CELLS * CONFIG_CELL_OCV_FULL_MV);
|
|
bat->ocv_empty =
|
|
0.001F * static_cast<float>(CONFIG_BAT_NUM_CELLS * CONFIG_CELL_OCV_EMPTY_MV);
|
|
|
|
// https://batteryuniversity.com/learn/article/charging_the_lead_acid_battery
|
|
bat->topping_cutoff_current = bat->nominal_capacity * 0.04F; // 3-5 % of C/1
|
|
|
|
bat->float_enabled = IS_ENABLED(CONFIG_CELL_FLOAT);
|
|
bat->float_recharge_time = CONFIG_CELL_FLOAT_RECHARGE_TIME;
|
|
bat->float_voltage =
|
|
0.001F * static_cast<float>(CONFIG_BAT_NUM_CELLS * CONFIG_CELL_FLOAT_VOLTAGE_MV);
|
|
|
|
bat->equalization_enabled = IS_ENABLED(CONFIG_CELL_EQUALIZATION);
|
|
bat->equalization_voltage =
|
|
0.001F
|
|
* static_cast<float>(CONFIG_BAT_NUM_CELLS * CONFIG_CELL_EQUALIZATION_VOLTAGE_MV);
|
|
bat->equalization_duration = CONFIG_CELL_EQUALIZATION_DURATION;
|
|
bat->equalization_current_limit = (1.0F / 7.0F) * bat->nominal_capacity;
|
|
bat->equalization_trigger_days = CONFIG_CELL_EQUALIZATION_TRIGGER_DAYS;
|
|
bat->equalization_trigger_deep_cycles = CONFIG_CELL_EQUALIZATION_TRIGGER_DEEP_CYCLES;
|
|
|
|
bat->temperature_compensation =
|
|
0.001F
|
|
* static_cast<float>(CONFIG_BAT_NUM_CELLS * CONFIG_CELL_TEMP_COMPENSATION_MV_K);
|
|
|
|
bat->charge_temp_max = CONFIG_BAT_CHARGE_TEMP_MAX;
|
|
bat->charge_temp_min = CONFIG_BAT_CHARGE_TEMP_MIN;
|
|
bat->discharge_temp_max = CONFIG_BAT_DISCHARGE_TEMP_MAX;
|
|
bat->discharge_temp_min = CONFIG_BAT_DISCHARGE_TEMP_MIN;
|
|
#else
|
|
LOG_ERR("Custom battery type cannot be initialized at runtime.");
|
|
#endif
|
|
break;
|
|
}
|
|
}
|
|
|
|
// checks settings in bat_conf for plausibility
|
|
bool battery_conf_check(BatConf *bat_conf)
|
|
{
|
|
// things to check:
|
|
// - load_disconnect/reconnect hysteresis makes sense?
|
|
// - cutoff current not extremely low/high
|
|
// - capacity plausible
|
|
//
|
|
|
|
struct condition
|
|
{
|
|
std::function<bool()> func;
|
|
const char *text;
|
|
};
|
|
|
|
const condition conditions[] = {
|
|
{ .func =
|
|
[bat_conf]() {
|
|
return bat_conf->load_reconnect_voltage
|
|
> (bat_conf->load_disconnect_voltage + 0.4f);
|
|
},
|
|
.text = "Load Reconnect Voltage must be higher than Load Disconnect Voltage + 0.4" },
|
|
{ .func =
|
|
[bat_conf]() {
|
|
return bat_conf->recharge_voltage < (bat_conf->topping_voltage - 0.4f);
|
|
},
|
|
.text = "Recharge Voltage must be lower than Topping Voltage - 0.4" },
|
|
{ .func =
|
|
[bat_conf]() {
|
|
return bat_conf->recharge_voltage > (bat_conf->load_disconnect_voltage + 1);
|
|
},
|
|
.text = "Recharge Voltage must be higher than Load Disconnect Voltage + 1.0" },
|
|
{ .func =
|
|
[bat_conf]() {
|
|
return bat_conf->load_disconnect_voltage
|
|
> (bat_conf->absolute_min_voltage + 0.4f);
|
|
},
|
|
.text = "Load Disconnecct Voltage must be higher than Absolute Min Voltage + 0.4" },
|
|
{ .func =
|
|
[bat_conf]() {
|
|
return bat_conf->internal_resistance
|
|
< bat_conf->load_disconnect_voltage * 0.1f / DISCHARGE_CURRENT_MAX;
|
|
},
|
|
.text = "Internal Battery Resistance must not cause more than 10% drop at Max Discharge "
|
|
"Current" },
|
|
{ .func =
|
|
[bat_conf]() {
|
|
return bat_conf->wire_resistance
|
|
< bat_conf->topping_voltage * 0.03f / DISCHARGE_CURRENT_MAX;
|
|
},
|
|
.text = "Wire Resistances must not cause more than 3% drop at Max Discharge Current" },
|
|
{ .func =
|
|
[bat_conf]() {
|
|
return bat_conf->topping_cutoff_current < (bat_conf->nominal_capacity / 10.0f);
|
|
},
|
|
.text = "Topping Cutoff Current must be less than 10% of Nominal Capacity (C/10)" },
|
|
{ .func = [bat_conf]() { return bat_conf->topping_cutoff_current > 0.01f; },
|
|
.text = "Topping Cutoff Current must be higher than 0.01A" },
|
|
{ .func =
|
|
[bat_conf]() {
|
|
return bat_conf->float_enabled == false
|
|
|| bat_conf->float_voltage < bat_conf->topping_voltage;
|
|
},
|
|
.text = "Floating Charge Voltage must be lower than Topping Voltage" },
|
|
{ .func =
|
|
[bat_conf]() {
|
|
return bat_conf->float_enabled == false
|
|
|| bat_conf->float_voltage > bat_conf->load_disconnect_voltage;
|
|
},
|
|
.text = "Floating Charge Voltage must be higher than Topping Voltage" },
|
|
};
|
|
|
|
bool result = true;
|
|
for (auto cond : conditions) {
|
|
bool cond_res = cond.func();
|
|
if (cond_res == false) {
|
|
LOG_ERR("battery_conf_check: failed condition '%s'", cond.text);
|
|
}
|
|
result = result && cond_res;
|
|
}
|
|
|
|
return result;
|
|
}
|
|
|
|
void battery_conf_overwrite(BatConf *source, BatConf *destination, Charger *charger)
|
|
{
|
|
// TODO: stop DC/DC
|
|
|
|
destination->topping_voltage = source->topping_voltage;
|
|
destination->recharge_voltage = source->recharge_voltage;
|
|
destination->load_reconnect_voltage = source->load_reconnect_voltage;
|
|
destination->load_disconnect_voltage = source->load_disconnect_voltage;
|
|
destination->absolute_max_voltage = source->absolute_max_voltage;
|
|
destination->absolute_min_voltage = source->absolute_min_voltage;
|
|
destination->charge_current_max = source->charge_current_max;
|
|
destination->topping_cutoff_current = source->topping_cutoff_current;
|
|
destination->topping_duration = source->topping_duration;
|
|
destination->float_enabled = source->float_enabled;
|
|
destination->float_voltage = source->float_voltage;
|
|
destination->float_recharge_time = source->float_recharge_time;
|
|
destination->charge_temp_max = source->charge_temp_max;
|
|
destination->charge_temp_min = source->charge_temp_min;
|
|
destination->discharge_temp_max = source->discharge_temp_max;
|
|
destination->discharge_temp_min = source->discharge_temp_min;
|
|
destination->temperature_compensation = source->temperature_compensation;
|
|
destination->internal_resistance = source->internal_resistance;
|
|
destination->wire_resistance = source->wire_resistance;
|
|
|
|
// reset Ah counter and SOH if battery nominal capacity was changed
|
|
if (destination->nominal_capacity != source->nominal_capacity) {
|
|
destination->nominal_capacity = source->nominal_capacity;
|
|
if (charger != NULL) {
|
|
charger->discharged_Ah = 0;
|
|
charger->usable_capacity = 0;
|
|
charger->soh = 0;
|
|
}
|
|
}
|
|
|
|
// TODO:
|
|
// - update also DC/DC etc. (now this function only works at system startup)
|
|
// - restart DC/DC
|
|
}
|
|
|
|
bool battery_conf_changed(BatConf *a, BatConf *b)
|
|
{
|
|
return (a->topping_voltage != b->topping_voltage || a->recharge_voltage != b->recharge_voltage
|
|
|| a->load_reconnect_voltage != b->load_reconnect_voltage
|
|
|| a->load_disconnect_voltage != b->load_disconnect_voltage
|
|
|| a->absolute_max_voltage != b->absolute_max_voltage
|
|
|| a->absolute_min_voltage != b->absolute_min_voltage
|
|
|| a->charge_current_max != b->charge_current_max
|
|
|| a->topping_cutoff_current != b->topping_cutoff_current
|
|
|| a->topping_duration != b->topping_duration || a->float_enabled != b->float_enabled
|
|
|| a->float_voltage != b->float_voltage
|
|
|| a->float_recharge_time != b->float_recharge_time
|
|
|| a->charge_temp_max != b->charge_temp_max || a->charge_temp_min != b->charge_temp_min
|
|
|| a->discharge_temp_max != b->discharge_temp_max
|
|
|| a->discharge_temp_min != b->discharge_temp_min
|
|
|| a->temperature_compensation != b->temperature_compensation
|
|
|| a->internal_resistance != b->internal_resistance
|
|
|| a->wire_resistance != b->wire_resistance);
|
|
}
|
|
|
|
void Charger::detect_num_batteries(BatConf *bat) const
|
|
{
|
|
if (port->bus->voltage > bat->absolute_min_voltage * 2
|
|
&& port->bus->voltage < bat->absolute_max_voltage * 2)
|
|
{
|
|
port->bus->series_multiplier = 2;
|
|
printf("Detected two batteries (total %.2f V max)\n", (double)bat->topping_voltage * 2);
|
|
}
|
|
else {
|
|
printf("Detected single battery (%.2f V max)\n", (double)bat->topping_voltage);
|
|
}
|
|
}
|
|
|
|
void Charger::update_soc(BatConf *bat_conf)
|
|
{
|
|
static int soc_filtered = 0; // SOC / 100 for better filtering
|
|
|
|
if (fabs(port->current) < 0.2f) {
|
|
int soc_new = (int)((port->bus->voltage - bat_conf->ocv_empty)
|
|
/ (bat_conf->ocv_full - bat_conf->ocv_empty) * 10000.0f);
|
|
|
|
if (soc_new > 500 && soc_filtered == 0) {
|
|
// bypass filter during initialization
|
|
soc_filtered = soc_new;
|
|
}
|
|
else {
|
|
// filtering to adjust SOC very slowly
|
|
soc_filtered += (soc_new - soc_filtered) / 100;
|
|
}
|
|
|
|
if (soc_filtered > 10000) {
|
|
soc_filtered = 10000;
|
|
}
|
|
else if (soc_filtered < 0) {
|
|
soc_filtered = 0;
|
|
}
|
|
soc = soc_filtered / 100;
|
|
}
|
|
|
|
discharged_Ah += -port->current / 3600.0F; // charged current is positive: change sign
|
|
}
|
|
|
|
void Charger::enter_state(int next_state)
|
|
{
|
|
LOG_DBG("Enter State: %d", next_state);
|
|
time_state_changed = uptime();
|
|
state = next_state;
|
|
}
|
|
|
|
void Charger::discharge_control(BatConf *bat_conf)
|
|
{
|
|
#if BOARD_HAS_LOAD_OUTPUT || BOARD_HAS_USB_OUTPUT
|
|
|
|
if (!empty) {
|
|
// as we don't have a proper SOC estimation, we determine an empty battery by the main
|
|
// load output being switched off
|
|
if (flags_check(&load.error_flags, ERR_LOAD_SHEDDING)) {
|
|
empty = true;
|
|
num_deep_discharges++;
|
|
|
|
if (usable_capacity == 0.0F) {
|
|
// reset to measured value if discharged the first time
|
|
usable_capacity = discharged_Ah;
|
|
}
|
|
else {
|
|
// slowly adapt new measurements with low-pass filter
|
|
usable_capacity = 0.8F * usable_capacity + 0.2F * discharged_Ah;
|
|
}
|
|
|
|
// simple SOH estimation
|
|
soh = usable_capacity / bat_conf->nominal_capacity;
|
|
}
|
|
}
|
|
else {
|
|
if (!flags_check(&load.error_flags, ERR_LOAD_SHEDDING)) {
|
|
empty = false;
|
|
}
|
|
}
|
|
|
|
// negative current limit = allowed battery discharge current
|
|
if (port->neg_current_limit < 0) {
|
|
|
|
// This limit should normally never be reached, as the load output settings should be
|
|
// higher. The flag can be used to trigger actions of last resort, e.g. deep-sleep
|
|
// of the charge controller itself.
|
|
if (port->bus->voltage
|
|
< dc_bus_src_control_voltage(port->bus, bat_conf->absolute_min_voltage))
|
|
{
|
|
port->neg_current_limit = 0;
|
|
device_status_set_error(&dev_stat, ERR_BAT_UNDERVOLTAGE);
|
|
}
|
|
|
|
if (bat_temperature > bat_conf->discharge_temp_max) {
|
|
port->neg_current_limit = 0;
|
|
device_status_set_error(&dev_stat, ERR_BAT_DIS_OVERTEMP);
|
|
}
|
|
else if (bat_temperature < bat_conf->discharge_temp_min) {
|
|
port->neg_current_limit = 0;
|
|
device_status_set_error(&dev_stat, ERR_BAT_DIS_UNDERTEMP);
|
|
}
|
|
}
|
|
else {
|
|
// discharging currently not allowed. should we allow it?
|
|
|
|
if (port->bus->voltage
|
|
>= dc_bus_src_control_voltage(port->bus, bat_conf->absolute_min_voltage + 0.1F))
|
|
{
|
|
device_status_clear_error(&dev_stat, ERR_BAT_UNDERVOLTAGE);
|
|
}
|
|
|
|
if (bat_temperature < bat_conf->discharge_temp_max - 1
|
|
&& bat_temperature > bat_conf->discharge_temp_min + 1)
|
|
{
|
|
device_status_clear_error(&dev_stat, ERR_BAT_DIS_OVERTEMP | ERR_BAT_DIS_UNDERTEMP);
|
|
}
|
|
|
|
if (!device_status_has_error(&dev_stat, ERR_BAT_UNDERVOLTAGE | ERR_BAT_DIS_OVERTEMP
|
|
| ERR_BAT_DIS_UNDERTEMP))
|
|
{
|
|
// discharge current is stored as absolute value in bat_conf, but defined
|
|
// as negative current for power port
|
|
port->neg_current_limit = -bat_conf->discharge_current_max;
|
|
}
|
|
}
|
|
#endif
|
|
}
|
|
|
|
void Charger::charge_control(BatConf *bat_conf)
|
|
{
|
|
// check battery temperature for charging direction
|
|
if (bat_temperature > bat_conf->charge_temp_max) {
|
|
port->pos_current_limit = 0;
|
|
device_status_set_error(&dev_stat, ERR_BAT_CHG_OVERTEMP);
|
|
enter_state(CHG_STATE_IDLE);
|
|
}
|
|
else if (bat_temperature < bat_conf->charge_temp_min) {
|
|
port->pos_current_limit = 0;
|
|
device_status_set_error(&dev_stat, ERR_BAT_CHG_UNDERTEMP);
|
|
enter_state(CHG_STATE_IDLE);
|
|
}
|
|
|
|
if (device_status_has_error(&dev_stat, ERR_BAT_OVERVOLTAGE)
|
|
&& port->bus->voltage
|
|
< (bat_conf->absolute_max_voltage - 0.5F) * port->bus->series_multiplier)
|
|
{
|
|
device_status_clear_error(&dev_stat, ERR_BAT_OVERVOLTAGE);
|
|
}
|
|
|
|
if (state != CHG_STATE_FOLLOWER && (uptime() - time_last_ctrl_msg) <= 1) {
|
|
enter_state(CHG_STATE_FOLLOWER);
|
|
}
|
|
|
|
// state machine
|
|
switch (state) {
|
|
case CHG_STATE_IDLE: {
|
|
if ((time_state_changed == CHARGER_TIME_NEVER
|
|
|| ((uptime() - time_state_changed) > bat_conf->time_limit_recharge
|
|
&& port->bus->voltage
|
|
< dc_bus_sink_control_voltage(port->bus, bat_conf->recharge_voltage)))
|
|
&& port->bus->voltage
|
|
> dc_bus_sink_control_voltage(port->bus, bat_conf->absolute_min_voltage)
|
|
&& bat_temperature < bat_conf->charge_temp_max - 1
|
|
&& bat_temperature > bat_conf->charge_temp_min + 1)
|
|
{
|
|
port->bus->sink_voltage_intercept =
|
|
bat_conf->topping_voltage
|
|
+ bat_conf->temperature_compensation * (bat_temperature - 25);
|
|
port->pos_current_limit = bat_conf->charge_current_max;
|
|
target_current_control = port->pos_current_limit;
|
|
full = false;
|
|
device_status_clear_error(&dev_stat, ERR_BAT_CHG_OVERTEMP);
|
|
device_status_clear_error(&dev_stat, ERR_BAT_CHG_UNDERTEMP);
|
|
device_status_clear_error(&dev_stat, ERR_BAT_OVERVOLTAGE);
|
|
enter_state(CHG_STATE_BULK);
|
|
}
|
|
break;
|
|
}
|
|
case CHG_STATE_BULK: {
|
|
// continuously adjust voltage setting for temperature compensation
|
|
port->bus->sink_voltage_intercept =
|
|
bat_conf->topping_voltage
|
|
+ bat_conf->temperature_compensation * (bat_temperature - 25);
|
|
|
|
if (port->bus->voltage > dc_bus_sink_control_voltage(port->bus, 0)) {
|
|
target_voltage_timer = 0;
|
|
enter_state(CHG_STATE_TOPPING);
|
|
}
|
|
break;
|
|
}
|
|
case CHG_STATE_TOPPING: {
|
|
// continuously adjust voltage setting for temperature compensation
|
|
port->bus->sink_voltage_intercept =
|
|
bat_conf->topping_voltage
|
|
+ bat_conf->temperature_compensation * (bat_temperature - 25);
|
|
|
|
// power sharing: multiple devices in parallel supply the same current
|
|
target_current_control = port->current_filtered;
|
|
|
|
if (port->bus->voltage_filtered >= dc_bus_sink_control_voltage(port->bus, 0) - 0.05F) {
|
|
// battery is full if topping target voltage is still reached (i.e. sufficient
|
|
// solar power available) and time limit or cut-off current reached
|
|
if (port->current_filtered < bat_conf->topping_cutoff_current
|
|
|| target_voltage_timer > bat_conf->topping_duration)
|
|
{
|
|
full = true;
|
|
}
|
|
target_voltage_timer++;
|
|
}
|
|
else if (uptime() - time_state_changed > 8 * 60 * 60) {
|
|
// in topping phase already for 8 hours (i.e. not enough solar power available)
|
|
// --> go back to bulk charging for the next day
|
|
enter_state(CHG_STATE_BULK);
|
|
}
|
|
|
|
if (full) {
|
|
num_full_charges++;
|
|
discharged_Ah = 0; // reset coulomb counter
|
|
|
|
if (bat_conf->equalization_enabled
|
|
&& ((uptime() - time_last_equalization) / (24 * 60 * 60)
|
|
>= bat_conf->equalization_trigger_days
|
|
|| num_deep_discharges - deep_dis_last_equalization
|
|
>= bat_conf->equalization_trigger_deep_cycles))
|
|
{
|
|
port->bus->sink_voltage_intercept = bat_conf->equalization_voltage;
|
|
port->pos_current_limit = bat_conf->equalization_current_limit;
|
|
enter_state(CHG_STATE_EQUALIZATION);
|
|
}
|
|
else if (bat_conf->float_enabled) {
|
|
port->bus->sink_voltage_intercept =
|
|
bat_conf->float_voltage
|
|
+ bat_conf->temperature_compensation * (bat_temperature - 25);
|
|
enter_state(CHG_STATE_FLOAT);
|
|
}
|
|
else {
|
|
port->pos_current_limit = 0;
|
|
enter_state(CHG_STATE_IDLE);
|
|
}
|
|
}
|
|
break;
|
|
}
|
|
case CHG_STATE_FLOAT: {
|
|
// continuously adjust voltage setting for temperature compensation
|
|
port->bus->sink_voltage_intercept =
|
|
bat_conf->float_voltage
|
|
+ bat_conf->temperature_compensation * (bat_temperature - 25);
|
|
|
|
target_current_control = port->current_filtered;
|
|
|
|
if (port->bus->voltage >= dc_bus_sink_control_voltage(port->bus, 0)) {
|
|
time_target_voltage_reached = uptime();
|
|
}
|
|
|
|
if ((uptime() - time_target_voltage_reached > bat_conf->float_recharge_time)
|
|
&& port->bus->voltage_filtered
|
|
< dc_bus_sink_control_voltage(port->bus, bat_conf->recharge_voltage))
|
|
{
|
|
// the battery was discharged: float voltage could not be reached anymore
|
|
port->pos_current_limit = bat_conf->charge_current_max;
|
|
full = false;
|
|
// assumption: float does not harm the battery --> never go back to idle
|
|
// (for Li-ion battery: disable float!)
|
|
enter_state(CHG_STATE_BULK);
|
|
}
|
|
break;
|
|
}
|
|
case CHG_STATE_EQUALIZATION: {
|
|
// continuously adjust voltage setting for temperature compensation
|
|
port->bus->sink_voltage_intercept =
|
|
bat_conf->equalization_voltage
|
|
+ bat_conf->temperature_compensation * (bat_temperature - 25);
|
|
|
|
target_current_control = port->current_filtered;
|
|
|
|
// current or time limit for equalization reached
|
|
if (uptime() - time_state_changed > bat_conf->equalization_duration) {
|
|
// reset triggers
|
|
time_last_equalization = uptime();
|
|
deep_dis_last_equalization = num_deep_discharges;
|
|
|
|
discharged_Ah = 0; // reset coulomb counter again
|
|
|
|
if (bat_conf->float_enabled) {
|
|
port->bus->sink_voltage_intercept =
|
|
bat_conf->float_voltage
|
|
+ bat_conf->temperature_compensation * (bat_temperature - 25);
|
|
enter_state(CHG_STATE_FLOAT);
|
|
}
|
|
else {
|
|
port->pos_current_limit = 0;
|
|
enter_state(CHG_STATE_IDLE);
|
|
}
|
|
}
|
|
break;
|
|
}
|
|
case CHG_STATE_FOLLOWER: {
|
|
if ((uptime() - time_last_ctrl_msg) > 1) {
|
|
// go back to normal state machine
|
|
port->pos_current_limit = bat_conf->charge_current_max;
|
|
enter_state(CHG_STATE_BULK);
|
|
}
|
|
else {
|
|
// set current target as received from external device
|
|
port->pos_current_limit = target_current_control;
|
|
// set safety limit for voltage
|
|
port->bus->sink_voltage_intercept = bat_conf->absolute_max_voltage;
|
|
}
|
|
break;
|
|
}
|
|
}
|
|
}
|
|
|
|
void Charger::init_terminal(BatConf *bat) const
|
|
{
|
|
port->bus->sink_voltage_intercept = bat->topping_voltage;
|
|
port->bus->src_voltage_intercept = bat->load_disconnect_voltage;
|
|
|
|
port->neg_current_limit = -bat->discharge_current_max;
|
|
port->pos_current_limit = bat->charge_current_max;
|
|
|
|
/*
|
|
* Negative sign for compensation of actual resistance
|
|
*
|
|
* droop_res is multiplied with number of series connected batteries to calculate control
|
|
* voltage, so we need to divide by number of batteries here for correction
|
|
*/
|
|
port->bus->sink_droop_res =
|
|
-bat->wire_resistance / static_cast<float>(port->bus->series_multiplier);
|
|
|
|
/*
|
|
* In discharging direction also include battery internal resistance for current-compensation
|
|
* of voltage setpoints
|
|
*/
|
|
port->bus->src_droop_res =
|
|
-bat->wire_resistance / static_cast<float>(port->bus->series_multiplier)
|
|
- bat->internal_resistance;
|
|
}
|