Martin JägerandClaude Opus 5.5 a428892916 app: convert device status to C struct
DeviceStatus becomes struct device_status with prefixed functions. The
error flag helpers are static inline functions in the header.

The implementation stays in C++ for now, as it reads data from objects
which are not converted yet. The header doesn't include the headers of
these objects anymore.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-01 15:21:57 +01:00

691 lines
28 KiB
C++

/*
* Copyright (c) The Libre Solar Project Contributors
*
* SPDX-License-Identifier: Apache-2.0
*/
#include "bat_charger.h"
#include <zephyr/kernel.h>
#include <zephyr/logging/log.h>
LOG_MODULE_REGISTER(bat_charger, CONFIG_BAT_LOG_LEVEL);
#include <functional>
#include <math.h> // for fabs function
#include <stdio.h>
#include "board.h"
#include "device_status.h"
#include "helper.h"
#include "load.h"
extern struct device_status dev_stat;
extern LoadOutput load;
// DISCHARGE_CURRENT_MAX used to estimate current-compensation of load disconnect voltage
#if BOARD_HAS_LOAD_OUTPUT
#define DISCHARGE_CURRENT_MAX DT_PROP(LOAD_SWITCH_NODE, current_max)
#else
#define DISCHARGE_CURRENT_MAX DT_PROP(DT_PATH(pcb), dcdc_current_max)
#endif
void battery_conf_init(BatConf *bat, int type, int num_cells, float nominal_capacity)
{
bat->nominal_capacity = nominal_capacity;
// 1C should be safe for all batteries
bat->charge_current_max = bat->nominal_capacity;
bat->discharge_current_max = bat->nominal_capacity;
bat->time_limit_recharge = 60; // sec
bat->topping_duration = 120 * 60; // sec
bat->charge_temp_max = 50;
bat->charge_temp_min = -10;
bat->discharge_temp_max = 50;
bat->discharge_temp_min = -10;
switch (type) {
case BAT_TYPE_FLOODED:
case BAT_TYPE_AGM:
case BAT_TYPE_GEL:
bat->absolute_max_voltage = static_cast<float>(num_cells) * 2.45F;
bat->topping_voltage = static_cast<float>(num_cells) * 2.4F;
bat->recharge_voltage = static_cast<float>(num_cells) * 2.2F;
// Cell-level thresholds based on EN 62509:2011 (both thresholds current-compensated)
bat->load_disconnect_voltage = static_cast<float>(num_cells) * 1.95F;
bat->load_reconnect_voltage = static_cast<float>(num_cells) * 2.10F;
// assumption: Battery selection matching charge controller
bat->internal_resistance =
static_cast<float>(num_cells) * (1.95F - 1.80F) / DISCHARGE_CURRENT_MAX;
bat->absolute_min_voltage = static_cast<float>(num_cells) * 1.6F;
// Voltages during idle (no charging/discharging current)
bat->ocv_full =
static_cast<float>(num_cells) * ((type == BAT_TYPE_FLOODED) ? 2.10F : 2.15F);
bat->ocv_empty = static_cast<float>(num_cells) * 1.90F;
// https://batteryuniversity.com/learn/article/charging_the_lead_acid_battery
bat->topping_cutoff_current = bat->nominal_capacity * 0.04F; // 3-5 % of C/1
bat->float_enabled = true;
bat->float_recharge_time = 30 * 60;
// Values as suggested in EN 62509:2011
bat->float_voltage =
static_cast<float>(num_cells) * ((type == BAT_TYPE_FLOODED) ? 2.35F : 2.3F);
// Enable for flooded batteries only, according to
// https://discoverbattery.com/battery-101/equalizing-flooded-batteries-only
bat->equalization_enabled = false;
// Values as suggested in EN 62509:2011
bat->equalization_voltage =
static_cast<float>(num_cells) * ((type == BAT_TYPE_FLOODED) ? 2.50F : 2.45F);
bat->equalization_duration = 60 * 60;
bat->equalization_current_limit = (1.0F / 7.0F) * bat->nominal_capacity;
bat->equalization_trigger_days = 60;
bat->equalization_trigger_deep_cycles = 10;
bat->temperature_compensation = -0.003F; // -3 mV/°C/cell
break;
case BAT_TYPE_LFP:
bat->absolute_max_voltage = static_cast<float>(num_cells) * 3.60F;
bat->topping_voltage = static_cast<float>(num_cells) * 3.55F; // CV voltage
bat->recharge_voltage = static_cast<float>(num_cells) * 3.35F;
bat->load_disconnect_voltage = static_cast<float>(num_cells) * 3.00F;
bat->load_reconnect_voltage = static_cast<float>(num_cells) * 3.15F;
// 5% voltage drop at max current
bat->internal_resistance = bat->load_disconnect_voltage * 0.05F / DISCHARGE_CURRENT_MAX;
bat->absolute_min_voltage = static_cast<float>(num_cells) * 2.0F;
// will give really nonlinear SOC calculation because of flat OCV of LFP cells...
bat->ocv_full = static_cast<float>(num_cells) * 3.4F;
bat->ocv_empty = static_cast<float>(num_cells) * 3.0F;
// C/10 cut-off at end of CV phase by default
bat->topping_cutoff_current = bat->nominal_capacity / 10;
bat->float_enabled = false;
bat->equalization_enabled = false;
bat->temperature_compensation = 0;
bat->charge_temp_min = 0;
break;
case BAT_TYPE_NMC:
case BAT_TYPE_NMC_HV:
bat->topping_voltage =
static_cast<float>(num_cells) * ((type == BAT_TYPE_NMC_HV) ? 4.35F : 4.20F);
bat->absolute_max_voltage =
bat->topping_voltage + static_cast<float>(num_cells) * 0.05F;
bat->recharge_voltage = static_cast<float>(num_cells) * 3.9F;
bat->load_disconnect_voltage = static_cast<float>(num_cells) * 3.3F;
bat->load_reconnect_voltage = static_cast<float>(num_cells) * 3.6F;
// 5% voltage drop at max current
bat->internal_resistance = bat->load_disconnect_voltage * 0.05F / DISCHARGE_CURRENT_MAX;
bat->absolute_min_voltage = static_cast<float>(num_cells) * 2.5F;
bat->ocv_full = static_cast<float>(num_cells) * 4.0F;
bat->ocv_empty = static_cast<float>(num_cells) * 3.0F;
// C/10 cut-off at end of CV phase by default
bat->topping_cutoff_current = bat->nominal_capacity / 10;
bat->float_enabled = false;
bat->equalization_enabled = false;
bat->temperature_compensation = 0;
bat->charge_temp_min = 0;
break;
case BAT_TYPE_CUSTOM:
#ifdef CONFIG_BAT_TYPE_CUSTOM
bat->absolute_max_voltage =
0.001F * static_cast<float>(CONFIG_BAT_NUM_CELLS * CONFIG_CELL_ABS_MAX_VOLTAGE_MV);
bat->topping_voltage =
0.001F * static_cast<float>(CONFIG_BAT_NUM_CELLS * CONFIG_CELL_TOPPING_VOLTAGE_MV);
bat->recharge_voltage =
0.001F * static_cast<float>(CONFIG_BAT_NUM_CELLS * CONFIG_CELL_RECHARGE_VOLTAGE_MV);
bat->load_disconnect_voltage =
0.001F
* static_cast<float>(CONFIG_BAT_NUM_CELLS * CONFIG_CELL_DISCONNECT_VOLTAGE_MV);
bat->load_reconnect_voltage =
0.001F
* static_cast<float>(CONFIG_BAT_NUM_CELLS * CONFIG_CELL_RECONNECT_VOLTAGE_MV);
bat->internal_resistance =
0.001F
* static_cast<float>(CONFIG_BAT_NUM_CELLS * CONFIG_CELL_INTERNAL_RESISTANCE_MOHM);
bat->absolute_min_voltage =
0.001F * static_cast<float>(CONFIG_BAT_NUM_CELLS * CONFIG_CELL_ABS_MIN_VOLTAGE_MV);
// Voltages during idle (no charging/discharging current)
bat->ocv_full =
0.001F * static_cast<float>(CONFIG_BAT_NUM_CELLS * CONFIG_CELL_OCV_FULL_MV);
bat->ocv_empty =
0.001F * static_cast<float>(CONFIG_BAT_NUM_CELLS * CONFIG_CELL_OCV_EMPTY_MV);
// https://batteryuniversity.com/learn/article/charging_the_lead_acid_battery
bat->topping_cutoff_current = bat->nominal_capacity * 0.04F; // 3-5 % of C/1
bat->float_enabled = IS_ENABLED(CONFIG_CELL_FLOAT);
bat->float_recharge_time = CONFIG_CELL_FLOAT_RECHARGE_TIME;
bat->float_voltage =
0.001F * static_cast<float>(CONFIG_BAT_NUM_CELLS * CONFIG_CELL_FLOAT_VOLTAGE_MV);
bat->equalization_enabled = IS_ENABLED(CONFIG_CELL_EQUALIZATION);
bat->equalization_voltage =
0.001F
* static_cast<float>(CONFIG_BAT_NUM_CELLS * CONFIG_CELL_EQUALIZATION_VOLTAGE_MV);
bat->equalization_duration = CONFIG_CELL_EQUALIZATION_DURATION;
bat->equalization_current_limit = (1.0F / 7.0F) * bat->nominal_capacity;
bat->equalization_trigger_days = CONFIG_CELL_EQUALIZATION_TRIGGER_DAYS;
bat->equalization_trigger_deep_cycles = CONFIG_CELL_EQUALIZATION_TRIGGER_DEEP_CYCLES;
bat->temperature_compensation =
0.001F
* static_cast<float>(CONFIG_BAT_NUM_CELLS * CONFIG_CELL_TEMP_COMPENSATION_MV_K);
bat->charge_temp_max = CONFIG_BAT_CHARGE_TEMP_MAX;
bat->charge_temp_min = CONFIG_BAT_CHARGE_TEMP_MIN;
bat->discharge_temp_max = CONFIG_BAT_DISCHARGE_TEMP_MAX;
bat->discharge_temp_min = CONFIG_BAT_DISCHARGE_TEMP_MIN;
#else
LOG_ERR("Custom battery type cannot be initialized at runtime.");
#endif
break;
}
}
// checks settings in bat_conf for plausibility
bool battery_conf_check(BatConf *bat_conf)
{
// things to check:
// - load_disconnect/reconnect hysteresis makes sense?
// - cutoff current not extremely low/high
// - capacity plausible
//
struct condition
{
std::function<bool()> func;
const char *text;
};
const condition conditions[] = {
{ .func =
[bat_conf]() {
return bat_conf->load_reconnect_voltage
> (bat_conf->load_disconnect_voltage + 0.4f);
},
.text = "Load Reconnect Voltage must be higher than Load Disconnect Voltage + 0.4" },
{ .func =
[bat_conf]() {
return bat_conf->recharge_voltage < (bat_conf->topping_voltage - 0.4f);
},
.text = "Recharge Voltage must be lower than Topping Voltage - 0.4" },
{ .func =
[bat_conf]() {
return bat_conf->recharge_voltage > (bat_conf->load_disconnect_voltage + 1);
},
.text = "Recharge Voltage must be higher than Load Disconnect Voltage + 1.0" },
{ .func =
[bat_conf]() {
return bat_conf->load_disconnect_voltage
> (bat_conf->absolute_min_voltage + 0.4f);
},
.text = "Load Disconnecct Voltage must be higher than Absolute Min Voltage + 0.4" },
{ .func =
[bat_conf]() {
return bat_conf->internal_resistance
< bat_conf->load_disconnect_voltage * 0.1f / DISCHARGE_CURRENT_MAX;
},
.text = "Internal Battery Resistance must not cause more than 10% drop at Max Discharge "
"Current" },
{ .func =
[bat_conf]() {
return bat_conf->wire_resistance
< bat_conf->topping_voltage * 0.03f / DISCHARGE_CURRENT_MAX;
},
.text = "Wire Resistances must not cause more than 3% drop at Max Discharge Current" },
{ .func =
[bat_conf]() {
return bat_conf->topping_cutoff_current < (bat_conf->nominal_capacity / 10.0f);
},
.text = "Topping Cutoff Current must be less than 10% of Nominal Capacity (C/10)" },
{ .func = [bat_conf]() { return bat_conf->topping_cutoff_current > 0.01f; },
.text = "Topping Cutoff Current must be higher than 0.01A" },
{ .func =
[bat_conf]() {
return bat_conf->float_enabled == false
|| bat_conf->float_voltage < bat_conf->topping_voltage;
},
.text = "Floating Charge Voltage must be lower than Topping Voltage" },
{ .func =
[bat_conf]() {
return bat_conf->float_enabled == false
|| bat_conf->float_voltage > bat_conf->load_disconnect_voltage;
},
.text = "Floating Charge Voltage must be higher than Topping Voltage" },
};
bool result = true;
for (auto cond : conditions) {
bool cond_res = cond.func();
if (cond_res == false) {
LOG_ERR("battery_conf_check: failed condition '%s'", cond.text);
}
result = result && cond_res;
}
return result;
}
void battery_conf_overwrite(BatConf *source, BatConf *destination, Charger *charger)
{
// TODO: stop DC/DC
destination->topping_voltage = source->topping_voltage;
destination->recharge_voltage = source->recharge_voltage;
destination->load_reconnect_voltage = source->load_reconnect_voltage;
destination->load_disconnect_voltage = source->load_disconnect_voltage;
destination->absolute_max_voltage = source->absolute_max_voltage;
destination->absolute_min_voltage = source->absolute_min_voltage;
destination->charge_current_max = source->charge_current_max;
destination->topping_cutoff_current = source->topping_cutoff_current;
destination->topping_duration = source->topping_duration;
destination->float_enabled = source->float_enabled;
destination->float_voltage = source->float_voltage;
destination->float_recharge_time = source->float_recharge_time;
destination->charge_temp_max = source->charge_temp_max;
destination->charge_temp_min = source->charge_temp_min;
destination->discharge_temp_max = source->discharge_temp_max;
destination->discharge_temp_min = source->discharge_temp_min;
destination->temperature_compensation = source->temperature_compensation;
destination->internal_resistance = source->internal_resistance;
destination->wire_resistance = source->wire_resistance;
// reset Ah counter and SOH if battery nominal capacity was changed
if (destination->nominal_capacity != source->nominal_capacity) {
destination->nominal_capacity = source->nominal_capacity;
if (charger != NULL) {
charger->discharged_Ah = 0;
charger->usable_capacity = 0;
charger->soh = 0;
}
}
// TODO:
// - update also DC/DC etc. (now this function only works at system startup)
// - restart DC/DC
}
bool battery_conf_changed(BatConf *a, BatConf *b)
{
return (a->topping_voltage != b->topping_voltage || a->recharge_voltage != b->recharge_voltage
|| a->load_reconnect_voltage != b->load_reconnect_voltage
|| a->load_disconnect_voltage != b->load_disconnect_voltage
|| a->absolute_max_voltage != b->absolute_max_voltage
|| a->absolute_min_voltage != b->absolute_min_voltage
|| a->charge_current_max != b->charge_current_max
|| a->topping_cutoff_current != b->topping_cutoff_current
|| a->topping_duration != b->topping_duration || a->float_enabled != b->float_enabled
|| a->float_voltage != b->float_voltage
|| a->float_recharge_time != b->float_recharge_time
|| a->charge_temp_max != b->charge_temp_max || a->charge_temp_min != b->charge_temp_min
|| a->discharge_temp_max != b->discharge_temp_max
|| a->discharge_temp_min != b->discharge_temp_min
|| a->temperature_compensation != b->temperature_compensation
|| a->internal_resistance != b->internal_resistance
|| a->wire_resistance != b->wire_resistance);
}
void Charger::detect_num_batteries(BatConf *bat) const
{
if (port->bus->voltage > bat->absolute_min_voltage * 2
&& port->bus->voltage < bat->absolute_max_voltage * 2)
{
port->bus->series_multiplier = 2;
printf("Detected two batteries (total %.2f V max)\n", (double)bat->topping_voltage * 2);
}
else {
printf("Detected single battery (%.2f V max)\n", (double)bat->topping_voltage);
}
}
void Charger::update_soc(BatConf *bat_conf)
{
static int soc_filtered = 0; // SOC / 100 for better filtering
if (fabs(port->current) < 0.2f) {
int soc_new = (int)((port->bus->voltage - bat_conf->ocv_empty)
/ (bat_conf->ocv_full - bat_conf->ocv_empty) * 10000.0f);
if (soc_new > 500 && soc_filtered == 0) {
// bypass filter during initialization
soc_filtered = soc_new;
}
else {
// filtering to adjust SOC very slowly
soc_filtered += (soc_new - soc_filtered) / 100;
}
if (soc_filtered > 10000) {
soc_filtered = 10000;
}
else if (soc_filtered < 0) {
soc_filtered = 0;
}
soc = soc_filtered / 100;
}
discharged_Ah += -port->current / 3600.0F; // charged current is positive: change sign
}
void Charger::enter_state(int next_state)
{
LOG_DBG("Enter State: %d", next_state);
time_state_changed = uptime();
state = next_state;
}
void Charger::discharge_control(BatConf *bat_conf)
{
#if BOARD_HAS_LOAD_OUTPUT || BOARD_HAS_USB_OUTPUT
if (!empty) {
// as we don't have a proper SOC estimation, we determine an empty battery by the main
// load output being switched off
if (flags_check(&load.error_flags, ERR_LOAD_SHEDDING)) {
empty = true;
num_deep_discharges++;
if (usable_capacity == 0.0F) {
// reset to measured value if discharged the first time
usable_capacity = discharged_Ah;
}
else {
// slowly adapt new measurements with low-pass filter
usable_capacity = 0.8F * usable_capacity + 0.2F * discharged_Ah;
}
// simple SOH estimation
soh = usable_capacity / bat_conf->nominal_capacity;
}
}
else {
if (!flags_check(&load.error_flags, ERR_LOAD_SHEDDING)) {
empty = false;
}
}
// negative current limit = allowed battery discharge current
if (port->neg_current_limit < 0) {
// This limit should normally never be reached, as the load output settings should be
// higher. The flag can be used to trigger actions of last resort, e.g. deep-sleep
// of the charge controller itself.
if (port->bus->voltage
< dc_bus_src_control_voltage(port->bus, bat_conf->absolute_min_voltage))
{
port->neg_current_limit = 0;
device_status_set_error(&dev_stat, ERR_BAT_UNDERVOLTAGE);
}
if (bat_temperature > bat_conf->discharge_temp_max) {
port->neg_current_limit = 0;
device_status_set_error(&dev_stat, ERR_BAT_DIS_OVERTEMP);
}
else if (bat_temperature < bat_conf->discharge_temp_min) {
port->neg_current_limit = 0;
device_status_set_error(&dev_stat, ERR_BAT_DIS_UNDERTEMP);
}
}
else {
// discharging currently not allowed. should we allow it?
if (port->bus->voltage
>= dc_bus_src_control_voltage(port->bus, bat_conf->absolute_min_voltage + 0.1F))
{
device_status_clear_error(&dev_stat, ERR_BAT_UNDERVOLTAGE);
}
if (bat_temperature < bat_conf->discharge_temp_max - 1
&& bat_temperature > bat_conf->discharge_temp_min + 1)
{
device_status_clear_error(&dev_stat, ERR_BAT_DIS_OVERTEMP | ERR_BAT_DIS_UNDERTEMP);
}
if (!device_status_has_error(&dev_stat, ERR_BAT_UNDERVOLTAGE | ERR_BAT_DIS_OVERTEMP
| ERR_BAT_DIS_UNDERTEMP))
{
// discharge current is stored as absolute value in bat_conf, but defined
// as negative current for power port
port->neg_current_limit = -bat_conf->discharge_current_max;
}
}
#endif
}
void Charger::charge_control(BatConf *bat_conf)
{
// check battery temperature for charging direction
if (bat_temperature > bat_conf->charge_temp_max) {
port->pos_current_limit = 0;
device_status_set_error(&dev_stat, ERR_BAT_CHG_OVERTEMP);
enter_state(CHG_STATE_IDLE);
}
else if (bat_temperature < bat_conf->charge_temp_min) {
port->pos_current_limit = 0;
device_status_set_error(&dev_stat, ERR_BAT_CHG_UNDERTEMP);
enter_state(CHG_STATE_IDLE);
}
if (device_status_has_error(&dev_stat, ERR_BAT_OVERVOLTAGE)
&& port->bus->voltage
< (bat_conf->absolute_max_voltage - 0.5F) * port->bus->series_multiplier)
{
device_status_clear_error(&dev_stat, ERR_BAT_OVERVOLTAGE);
}
if (state != CHG_STATE_FOLLOWER && (uptime() - time_last_ctrl_msg) <= 1) {
enter_state(CHG_STATE_FOLLOWER);
}
// state machine
switch (state) {
case CHG_STATE_IDLE: {
if ((time_state_changed == CHARGER_TIME_NEVER
|| ((uptime() - time_state_changed) > bat_conf->time_limit_recharge
&& port->bus->voltage
< dc_bus_sink_control_voltage(port->bus, bat_conf->recharge_voltage)))
&& port->bus->voltage
> dc_bus_sink_control_voltage(port->bus, bat_conf->absolute_min_voltage)
&& bat_temperature < bat_conf->charge_temp_max - 1
&& bat_temperature > bat_conf->charge_temp_min + 1)
{
port->bus->sink_voltage_intercept =
bat_conf->topping_voltage
+ bat_conf->temperature_compensation * (bat_temperature - 25);
port->pos_current_limit = bat_conf->charge_current_max;
target_current_control = port->pos_current_limit;
full = false;
device_status_clear_error(&dev_stat, ERR_BAT_CHG_OVERTEMP);
device_status_clear_error(&dev_stat, ERR_BAT_CHG_UNDERTEMP);
device_status_clear_error(&dev_stat, ERR_BAT_OVERVOLTAGE);
enter_state(CHG_STATE_BULK);
}
break;
}
case CHG_STATE_BULK: {
// continuously adjust voltage setting for temperature compensation
port->bus->sink_voltage_intercept =
bat_conf->topping_voltage
+ bat_conf->temperature_compensation * (bat_temperature - 25);
if (port->bus->voltage > dc_bus_sink_control_voltage(port->bus, 0)) {
target_voltage_timer = 0;
enter_state(CHG_STATE_TOPPING);
}
break;
}
case CHG_STATE_TOPPING: {
// continuously adjust voltage setting for temperature compensation
port->bus->sink_voltage_intercept =
bat_conf->topping_voltage
+ bat_conf->temperature_compensation * (bat_temperature - 25);
// power sharing: multiple devices in parallel supply the same current
target_current_control = port->current_filtered;
if (port->bus->voltage_filtered >= dc_bus_sink_control_voltage(port->bus, 0) - 0.05F) {
// battery is full if topping target voltage is still reached (i.e. sufficient
// solar power available) and time limit or cut-off current reached
if (port->current_filtered < bat_conf->topping_cutoff_current
|| target_voltage_timer > bat_conf->topping_duration)
{
full = true;
}
target_voltage_timer++;
}
else if (uptime() - time_state_changed > 8 * 60 * 60) {
// in topping phase already for 8 hours (i.e. not enough solar power available)
// --> go back to bulk charging for the next day
enter_state(CHG_STATE_BULK);
}
if (full) {
num_full_charges++;
discharged_Ah = 0; // reset coulomb counter
if (bat_conf->equalization_enabled
&& ((uptime() - time_last_equalization) / (24 * 60 * 60)
>= bat_conf->equalization_trigger_days
|| num_deep_discharges - deep_dis_last_equalization
>= bat_conf->equalization_trigger_deep_cycles))
{
port->bus->sink_voltage_intercept = bat_conf->equalization_voltage;
port->pos_current_limit = bat_conf->equalization_current_limit;
enter_state(CHG_STATE_EQUALIZATION);
}
else if (bat_conf->float_enabled) {
port->bus->sink_voltage_intercept =
bat_conf->float_voltage
+ bat_conf->temperature_compensation * (bat_temperature - 25);
enter_state(CHG_STATE_FLOAT);
}
else {
port->pos_current_limit = 0;
enter_state(CHG_STATE_IDLE);
}
}
break;
}
case CHG_STATE_FLOAT: {
// continuously adjust voltage setting for temperature compensation
port->bus->sink_voltage_intercept =
bat_conf->float_voltage
+ bat_conf->temperature_compensation * (bat_temperature - 25);
target_current_control = port->current_filtered;
if (port->bus->voltage >= dc_bus_sink_control_voltage(port->bus, 0)) {
time_target_voltage_reached = uptime();
}
if ((uptime() - time_target_voltage_reached > bat_conf->float_recharge_time)
&& port->bus->voltage_filtered
< dc_bus_sink_control_voltage(port->bus, bat_conf->recharge_voltage))
{
// the battery was discharged: float voltage could not be reached anymore
port->pos_current_limit = bat_conf->charge_current_max;
full = false;
// assumption: float does not harm the battery --> never go back to idle
// (for Li-ion battery: disable float!)
enter_state(CHG_STATE_BULK);
}
break;
}
case CHG_STATE_EQUALIZATION: {
// continuously adjust voltage setting for temperature compensation
port->bus->sink_voltage_intercept =
bat_conf->equalization_voltage
+ bat_conf->temperature_compensation * (bat_temperature - 25);
target_current_control = port->current_filtered;
// current or time limit for equalization reached
if (uptime() - time_state_changed > bat_conf->equalization_duration) {
// reset triggers
time_last_equalization = uptime();
deep_dis_last_equalization = num_deep_discharges;
discharged_Ah = 0; // reset coulomb counter again
if (bat_conf->float_enabled) {
port->bus->sink_voltage_intercept =
bat_conf->float_voltage
+ bat_conf->temperature_compensation * (bat_temperature - 25);
enter_state(CHG_STATE_FLOAT);
}
else {
port->pos_current_limit = 0;
enter_state(CHG_STATE_IDLE);
}
}
break;
}
case CHG_STATE_FOLLOWER: {
if ((uptime() - time_last_ctrl_msg) > 1) {
// go back to normal state machine
port->pos_current_limit = bat_conf->charge_current_max;
enter_state(CHG_STATE_BULK);
}
else {
// set current target as received from external device
port->pos_current_limit = target_current_control;
// set safety limit for voltage
port->bus->sink_voltage_intercept = bat_conf->absolute_max_voltage;
}
break;
}
}
}
void Charger::init_terminal(BatConf *bat) const
{
port->bus->sink_voltage_intercept = bat->topping_voltage;
port->bus->src_voltage_intercept = bat->load_disconnect_voltage;
port->neg_current_limit = -bat->discharge_current_max;
port->pos_current_limit = bat->charge_current_max;
/*
* Negative sign for compensation of actual resistance
*
* droop_res is multiplied with number of series connected batteries to calculate control
* voltage, so we need to divide by number of batteries here for correction
*/
port->bus->sink_droop_res =
-bat->wire_resistance / static_cast<float>(port->bus->series_multiplier);
/*
* In discharging direction also include battery internal resistance for current-compensation
* of voltage setpoints
*/
port->bus->src_droop_res =
-bat->wire_resistance / static_cast<float>(port->bus->series_multiplier)
- bat->internal_resistance;
}