407 lines
17 KiB
C++
407 lines
17 KiB
C++
/* LibreSolar charge controller firmware
|
|
* Copyright (c) 2016-2019 Martin Jäger (www.libre.solar)
|
|
*
|
|
* Licensed under the Apache License, Version 2.0 (the "License");
|
|
* you may not use this file except in compliance with the License.
|
|
* You may obtain a copy of the License at
|
|
*
|
|
* http://www.apache.org/licenses/LICENSE-2.0
|
|
*
|
|
* Unless required by applicable law or agreed to in writing, software
|
|
* distributed under the License is distributed on an "AS IS" BASIS,
|
|
* WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
|
|
* See the License for the specific language governing permissions and
|
|
* limitations under the License.
|
|
*/
|
|
|
|
#include "bat_charger.h"
|
|
#include "config.h"
|
|
#include "pcb.h"
|
|
|
|
#include "dc_bus.h"
|
|
#include "load.h"
|
|
#include "log.h"
|
|
|
|
#include <math.h> // for fabs function
|
|
#include <stdio.h>
|
|
#include <time.h>
|
|
|
|
void battery_conf_init(battery_conf_t *bat, bat_type type, int num_cells, float nominal_capacity)
|
|
{
|
|
bat->nominal_capacity = nominal_capacity;
|
|
|
|
// common values for all batteries
|
|
bat->charge_current_max = bat->nominal_capacity; // 1C should be safe for all batteries
|
|
|
|
bat->time_limit_recharge = 60; // sec
|
|
bat->time_limit_topping = 120*60; // sec
|
|
|
|
bat->charge_temp_max = 50;
|
|
bat->charge_temp_min = -10;
|
|
bat->discharge_temp_max = 50;
|
|
bat->discharge_temp_min = -10;
|
|
|
|
switch (type)
|
|
{
|
|
case BAT_TYPE_FLOODED:
|
|
case BAT_TYPE_AGM:
|
|
case BAT_TYPE_GEL:
|
|
bat->voltage_absolute_max = num_cells * 2.45;
|
|
bat->voltage_topping = num_cells * 2.4;
|
|
bat->voltage_recharge = num_cells * 2.3;
|
|
|
|
// Cell-level thresholds based on EN 62509:2011 (both thresholds current-compensated)
|
|
bat->voltage_load_disconnect = num_cells * 1.95;
|
|
bat->voltage_load_reconnect = num_cells * 2.05; // maybe increase to 2.10, if hysteresis observed?
|
|
bat->internal_resistance = num_cells * (1.95 - 1.80) / LOAD_CURRENT_MAX; // assumption: Battery selection matching charge controller
|
|
|
|
bat->voltage_absolute_min = num_cells * 1.8;
|
|
|
|
bat->ocv_full = num_cells * 2.15;
|
|
bat->ocv_empty = num_cells * 1.95;
|
|
|
|
// https://batteryuniversity.com/learn/article/charging_the_lead_acid_battery
|
|
bat->current_cutoff_topping = bat->nominal_capacity * 0.04; // 3-5 % of C/1
|
|
|
|
bat->trickle_enabled = true;
|
|
bat->time_trickle_recharge = 30*60;
|
|
// Values as suggested in EN 62509:2011
|
|
bat->voltage_trickle = num_cells * ((type == BAT_TYPE_FLOODED) ? 2.35 : 2.3);
|
|
|
|
// Enable for flooded batteries only, according to
|
|
// https://discoverbattery.com/battery-101/equalizing-flooded-batteries-only
|
|
bat->equalization_enabled = false;
|
|
// Values as suggested in EN 62509:2011
|
|
bat->voltage_equalization = num_cells * ((type == BAT_TYPE_FLOODED) ? 2.50 : 2.45);
|
|
bat->time_limit_equalization = 60*60;
|
|
bat->current_limit_equalization = (1.0 / 7.0) * bat->nominal_capacity;
|
|
bat->equalization_trigger_time = 8; // weeks
|
|
bat->equalization_trigger_deep_cycles = 10; // times
|
|
|
|
// not yet implemented...
|
|
bat->temperature_compensation = -0.003; // -3 mV/°C/cell
|
|
break;
|
|
|
|
case BAT_TYPE_LFP:
|
|
bat->voltage_absolute_max = num_cells * 3.60;
|
|
bat->voltage_topping = num_cells * 3.55; // CV voltage
|
|
bat->voltage_recharge = num_cells * 3.35;
|
|
|
|
bat->voltage_load_disconnect = num_cells * 3.0;
|
|
bat->voltage_load_reconnect = num_cells * 3.15;
|
|
bat->internal_resistance = bat->voltage_load_disconnect * 0.05 / LOAD_CURRENT_MAX; // 5% voltage drop at max current
|
|
bat->voltage_absolute_min = num_cells * 2.0;
|
|
|
|
bat->ocv_full = num_cells * 3.4; // will give really bad SOC calculation
|
|
bat->ocv_empty = num_cells * 3.0; // because of flat OCV of LFP cells...
|
|
|
|
bat->current_cutoff_topping = bat->nominal_capacity / 10; // C/10 cut-off at end of CV phase by default
|
|
|
|
bat->trickle_enabled = false;
|
|
bat->equalization_enabled = false;
|
|
bat->temperature_compensation = 0.0;
|
|
bat->charge_temp_min = 0;
|
|
break;
|
|
|
|
case BAT_TYPE_NMC:
|
|
case BAT_TYPE_NMC_HV:
|
|
bat->voltage_topping = num_cells * ((type == BAT_TYPE_NMC_HV) ? 4.35 : 4.20);
|
|
bat->voltage_absolute_max = num_cells * (bat->voltage_topping + 0.05);
|
|
bat->voltage_recharge = num_cells * 3.9;
|
|
|
|
bat->voltage_load_disconnect = num_cells * 3.3;
|
|
bat->voltage_load_reconnect = num_cells * 3.6;
|
|
bat->internal_resistance = bat->voltage_load_disconnect * 0.05 / LOAD_CURRENT_MAX; // 5% voltage drop at max current
|
|
|
|
bat->voltage_absolute_min = num_cells * 2.5;
|
|
|
|
bat->ocv_full = num_cells * 4.0;
|
|
bat->ocv_empty = num_cells * 3.0;
|
|
|
|
bat->current_cutoff_topping = bat->nominal_capacity / 10; // C/10 cut-off at end of CV phase by default
|
|
|
|
bat->trickle_enabled = false;
|
|
bat->equalization_enabled = false;
|
|
bat->temperature_compensation = 0.0;
|
|
bat->charge_temp_min = 0;
|
|
break;
|
|
|
|
case BAT_TYPE_NONE:
|
|
break;
|
|
}
|
|
}
|
|
|
|
// checks settings in bat_conf for plausibility
|
|
bool battery_conf_check(battery_conf_t *bat_conf)
|
|
{
|
|
// things to check:
|
|
// - load_disconnect/reconnect hysteresis makes sense?
|
|
// - cutoff current not extremely low/high
|
|
// - capacity plausible
|
|
|
|
/*
|
|
printf("battery_conf_check: %d %d %d %d %d %d %d\n",
|
|
bat_conf->voltage_load_reconnect > (bat_conf->voltage_load_disconnect + 0.6),
|
|
bat_conf->voltage_recharge < (bat_conf->voltage_max - 0.4),
|
|
bat_conf->voltage_recharge > (bat_conf->voltage_load_disconnect + 1),
|
|
bat_conf->voltage_load_disconnect > (bat_conf->voltage_absolute_min + 0.4),
|
|
bat_conf->current_cutoff_CV < (bat_conf->nominal_capacity / 10.0), // C/10 or lower allowed
|
|
bat_conf->current_cutoff_CV > 0.01,
|
|
(bat_conf->trickle_enabled == false ||
|
|
(bat_conf->voltage_trickle < bat_conf->voltage_max &&
|
|
bat_conf->voltage_trickle > bat_conf->voltage_load_disconnect))
|
|
);
|
|
*/
|
|
|
|
return
|
|
(bat_conf->voltage_load_reconnect > (bat_conf->voltage_load_disconnect + 0.4) &&
|
|
bat_conf->voltage_recharge < (bat_conf->voltage_topping - 0.4) &&
|
|
bat_conf->voltage_recharge > (bat_conf->voltage_load_disconnect + 1) &&
|
|
bat_conf->voltage_load_disconnect > (bat_conf->voltage_absolute_min + 0.4) &&
|
|
bat_conf->internal_resistance < bat_conf->voltage_load_disconnect * 0.1 / LOAD_CURRENT_MAX && // max. 10% drop
|
|
bat_conf->wire_resistance < bat_conf->voltage_topping * 0.03 / LOAD_CURRENT_MAX && // max. 3% loss
|
|
bat_conf->current_cutoff_topping < (bat_conf->nominal_capacity / 10.0) && // C/10 or lower allowed
|
|
bat_conf->current_cutoff_topping > 0.01 &&
|
|
(bat_conf->trickle_enabled == false ||
|
|
(bat_conf->voltage_trickle < bat_conf->voltage_topping &&
|
|
bat_conf->voltage_trickle > bat_conf->voltage_load_disconnect))
|
|
);
|
|
}
|
|
|
|
void battery_conf_overwrite(battery_conf_t *source, battery_conf_t *destination, charger_t *charger)
|
|
{
|
|
// TODO: stop DC/DC
|
|
|
|
destination->voltage_topping = source->voltage_topping;
|
|
destination->voltage_recharge = source->voltage_recharge;
|
|
destination->voltage_load_reconnect = source->voltage_load_reconnect;
|
|
destination->voltage_load_disconnect = source->voltage_load_disconnect;
|
|
destination->voltage_absolute_max = source->voltage_absolute_max;
|
|
destination->voltage_absolute_min = source->voltage_absolute_min;
|
|
destination->charge_current_max = source->charge_current_max;
|
|
destination->current_cutoff_topping = source->current_cutoff_topping;
|
|
destination->time_limit_topping = source->time_limit_topping;
|
|
destination->trickle_enabled = source->trickle_enabled;
|
|
destination->voltage_trickle = source->voltage_trickle;
|
|
destination->time_trickle_recharge = source->time_trickle_recharge;
|
|
destination->charge_temp_max = source->charge_temp_max;
|
|
destination->charge_temp_min = source->charge_temp_min;
|
|
destination->discharge_temp_max = source->discharge_temp_max;
|
|
destination->discharge_temp_min = source->discharge_temp_min;
|
|
destination->temperature_compensation = source->temperature_compensation;
|
|
destination->internal_resistance = source->internal_resistance;
|
|
destination->wire_resistance = source->wire_resistance;
|
|
|
|
// reset Ah counter and SOH if battery nominal capacity was changed
|
|
if (destination->nominal_capacity != source->nominal_capacity) {
|
|
destination->nominal_capacity = source->nominal_capacity;
|
|
if (charger != NULL) {
|
|
charger->discharged_Ah = 0;
|
|
charger->usable_capacity = 0;
|
|
charger->soh = 0;
|
|
}
|
|
}
|
|
|
|
// TODO:
|
|
// - update also DC/DC etc. (now this function only works at system startup)
|
|
// - restart DC/DC
|
|
}
|
|
|
|
|
|
void charger_init(charger_t *charger)
|
|
{
|
|
charger->num_batteries = 1; // initialize with only one battery in series
|
|
charger->soh = 100; // assume new battery
|
|
charger->bat_temperature = 25.0;
|
|
}
|
|
|
|
void charger_detect_num_batteries(charger_t *charger, battery_conf_t *bat, dc_bus_t *bus)
|
|
{
|
|
if (bus->voltage > bat->voltage_absolute_min * 2 &&
|
|
bus->voltage < bat->voltage_absolute_max * 2) {
|
|
charger->num_batteries = 2;
|
|
printf("Detected 24V battery\n");
|
|
}
|
|
else {
|
|
printf("Detected 12V battery\n");
|
|
}
|
|
}
|
|
|
|
void battery_update_soc(battery_conf_t *bat_conf, charger_t *charger, dc_bus_t *bus)
|
|
{
|
|
static int soc_filtered = 0; // SOC / 100 for better filtering
|
|
|
|
if (fabs(bus->current) < 0.2) {
|
|
int soc_new = (int)((bus->voltage - bat_conf->ocv_empty) /
|
|
(bat_conf->ocv_full - bat_conf->ocv_empty) * 10000.0);
|
|
|
|
if (soc_new > 10000) {
|
|
soc_new = 10000;
|
|
}
|
|
else if (soc_new < 0) {
|
|
soc_new = 0;
|
|
}
|
|
|
|
if (soc_new > 500 && soc_filtered == 0) {
|
|
// bypass filter during initialization
|
|
soc_filtered = soc_new;
|
|
}
|
|
else {
|
|
// filtering to adjust SOC very slowly
|
|
soc_filtered += (soc_new - soc_filtered) / 100;
|
|
}
|
|
charger->soc = soc_filtered / 100;
|
|
}
|
|
|
|
charger->discharged_Ah += -bus->current / 3600.0; // charged current is positive --> change sign
|
|
}
|
|
|
|
static void _enter_state(charger_t* charger, int next_state)
|
|
{
|
|
//printf("Enter State: %d\n", next_state);
|
|
charger->time_state_changed = time(NULL);
|
|
charger->state = next_state;
|
|
}
|
|
|
|
void charger_state_machine(dc_bus_t *bus, battery_conf_t *bat_conf, charger_t *charger)
|
|
{
|
|
//printf("time_state_change = %d, time = %d, v_bat = %f, i_bat = %f\n", charger->time_state_changed, time(NULL), voltage, current);
|
|
|
|
// Load management
|
|
// battery port input state (i.e. battery discharging direction) defines load state
|
|
if (bus->dis_allowed == true
|
|
&& bus->voltage < (bat_conf->voltage_load_disconnect - bus->current * bus->dis_droop_res) * charger->num_batteries)
|
|
{
|
|
bus->dis_allowed = false;
|
|
charger->num_deep_discharges++;
|
|
|
|
if (charger->usable_capacity < 0.1) {
|
|
charger->usable_capacity = charger->discharged_Ah;
|
|
} else {
|
|
// slowly adapt new measurements with low-pass filter
|
|
charger->usable_capacity = 0.8 * charger->usable_capacity + 0.2 * charger->discharged_Ah;
|
|
}
|
|
|
|
// simple SOH estimation
|
|
charger->soh = charger->usable_capacity / bat_conf->nominal_capacity;
|
|
}
|
|
else if (bus->dis_allowed == true
|
|
&& (charger->bat_temperature > bat_conf->discharge_temp_max
|
|
|| charger->bat_temperature < bat_conf->discharge_temp_min))
|
|
{
|
|
bus->dis_allowed = false;
|
|
}
|
|
|
|
if (bus->voltage >= (bat_conf->voltage_load_reconnect - bus->current * bus->dis_droop_res) * charger->num_batteries
|
|
&& charger->bat_temperature < bat_conf->discharge_temp_max - 1
|
|
&& charger->bat_temperature > bat_conf->discharge_temp_min + 1)
|
|
{
|
|
bus->dis_allowed = true;
|
|
}
|
|
|
|
// check battery temperature
|
|
if (charger->bat_temperature > bat_conf->charge_temp_max
|
|
|| charger->bat_temperature < bat_conf->charge_temp_min)
|
|
{
|
|
bus->chg_allowed = false;
|
|
_enter_state(charger, CHG_STATE_IDLE);
|
|
}
|
|
|
|
// state machine
|
|
switch (charger->state) {
|
|
case CHG_STATE_IDLE: {
|
|
if (bus->voltage < bat_conf->voltage_recharge * charger->num_batteries
|
|
&& (time(NULL) - charger->time_state_changed) > bat_conf->time_limit_recharge
|
|
&& charger->bat_temperature < bat_conf->charge_temp_max - 1
|
|
&& charger->bat_temperature > bat_conf->charge_temp_min + 1)
|
|
{
|
|
bus->chg_voltage_target = (bat_conf->voltage_topping + bat_conf->temperature_compensation * (charger->bat_temperature - 25)) * charger->num_batteries;
|
|
bus->chg_current_max = bat_conf->charge_current_max;
|
|
bus->chg_allowed = true;
|
|
charger->full = false;
|
|
_enter_state(charger, CHG_STATE_BULK);
|
|
}
|
|
break;
|
|
}
|
|
case CHG_STATE_BULK: {
|
|
// continuously adjust voltage setting for temperature compensation
|
|
bus->chg_voltage_target = (bat_conf->voltage_topping + bat_conf->temperature_compensation * (charger->bat_temperature - 25)) * charger->num_batteries;
|
|
|
|
if (bus->voltage > (bus->chg_voltage_target - bus->current * bus->chg_droop_res) * charger->num_batteries) {
|
|
_enter_state(charger, CHG_STATE_TOPPING);
|
|
}
|
|
break;
|
|
}
|
|
case CHG_STATE_TOPPING: {
|
|
// continuously adjust voltage setting for temperature compensation
|
|
bus->chg_voltage_target = (bat_conf->voltage_topping + bat_conf->temperature_compensation * (charger->bat_temperature - 25)) * charger->num_batteries;
|
|
|
|
if (bus->voltage >= (bus->chg_voltage_target - bus->current * bus->chg_droop_res) * charger->num_batteries) {
|
|
charger->time_voltage_limit_reached = time(NULL);
|
|
}
|
|
|
|
// cut-off limit reached because battery full (i.e. CV limit still
|
|
// reached by available solar power within last 2s) or CV period long enough?
|
|
if ((bus->current < bat_conf->current_cutoff_topping && (time(NULL) - charger->time_voltage_limit_reached) < 2)
|
|
|| (time(NULL) - charger->time_state_changed) > bat_conf->time_limit_topping)
|
|
{
|
|
charger->full = true;
|
|
charger->num_full_charges++;
|
|
charger->discharged_Ah = 0; // reset coulomb counter
|
|
|
|
/*if (bat_conf->equalization_enabled) {
|
|
// TODO: additional conditions!
|
|
bus->chg_voltage_target = bat_conf->voltage_equalization;
|
|
bus->chg_current_max = bat_conf->current_limit_equalization;
|
|
_enter_state(charger, CHG_STATE_EQUALIZATION);
|
|
}
|
|
else */if (bat_conf->trickle_enabled) {
|
|
bus->chg_voltage_target = (bat_conf->voltage_trickle + bat_conf->temperature_compensation * (charger->bat_temperature - 25)) * charger->num_batteries;
|
|
_enter_state(charger, CHG_STATE_TRICKLE);
|
|
}
|
|
else {
|
|
bus->chg_current_max = 0;
|
|
bus->chg_allowed = false;
|
|
_enter_state(charger, CHG_STATE_IDLE);
|
|
}
|
|
}
|
|
break;
|
|
}
|
|
case CHG_STATE_TRICKLE: {
|
|
// continuously adjust voltage setting for temperature compensation
|
|
bus->chg_voltage_target = (bat_conf->voltage_trickle + bat_conf->temperature_compensation * (charger->bat_temperature - 25)) * charger->num_batteries;
|
|
|
|
if (bus->voltage >= (bus->chg_voltage_target - bus->current * bus->chg_droop_res) * charger->num_batteries) {
|
|
charger->time_voltage_limit_reached = time(NULL);
|
|
}
|
|
|
|
if (time(NULL) - charger->time_voltage_limit_reached > bat_conf->time_trickle_recharge)
|
|
{
|
|
bus->chg_current_max = bat_conf->charge_current_max;
|
|
charger->full = false;
|
|
_enter_state(charger, CHG_STATE_BULK);
|
|
}
|
|
// assumption: trickle does not harm the battery --> never go back to idle
|
|
// (for Li-ion battery: disable trickle!)
|
|
break;
|
|
}
|
|
}
|
|
}
|
|
|
|
void battery_init_dc_bus(dc_bus_t *bus, battery_conf_t *bat, unsigned int num_batteries)
|
|
{
|
|
unsigned int n = (num_batteries == 2 ? 2 : 1); // only 1 or 2 allowed
|
|
|
|
bus->dis_allowed = true;
|
|
bus->dis_voltage_start = bat->voltage_load_reconnect * n;
|
|
bus->dis_voltage_stop = bat->voltage_load_disconnect * n;
|
|
bus->dis_current_max = -bat->charge_current_max; // TODO: discharge current
|
|
bus->dis_droop_res = -(bat->internal_resistance + -bat->wire_resistance) * n; // negative sign for compensation of actual resistance
|
|
|
|
bus->chg_allowed = true;
|
|
bus->chg_voltage_target = bat->voltage_topping * n;
|
|
bus->chg_voltage_min = bat->voltage_absolute_min * n;
|
|
bus->chg_current_max = bat->charge_current_max;
|
|
bus->chg_droop_res = -bat->wire_resistance * n; // negative sign for compensation of actual resistance
|
|
}
|