Identified issues: - The load output and USB charging port shared the same state machine, which did not allow to set different switch-off thresholds. - Load error codes were global, so it was not possible to have multiple load instances. This commit introduces load-specific error_flags, makes the LoadOutput class inherit from PowerPort (to improve code readability), separates the load driver better from higher level implementation and adds a second LoadOutput object for the USB charging port.
108 lines
2.8 KiB
C++
108 lines
2.8 KiB
C++
/*
|
|
* Copyright (c) 2018 Martin Jäger / Libre Solar
|
|
*
|
|
* SPDX-License-Identifier: Apache-2.0
|
|
*/
|
|
|
|
#include "tests.h"
|
|
#include "daq_stub.h"
|
|
#include "daq.h"
|
|
|
|
#include <time.h>
|
|
#include <stdio.h>
|
|
#include <math.h>
|
|
|
|
#include "setup.h"
|
|
|
|
static AdcValues adcval;
|
|
|
|
const float dcdc_current_sun = 3;
|
|
const float load_current = 1;
|
|
const int sun_hours = 1;
|
|
const int night_hours = 3;
|
|
|
|
void energy_calculation_init()
|
|
{
|
|
dev_stat.solar_in_total_Wh = 0;
|
|
dev_stat.load_out_total_Wh = 0;
|
|
dev_stat.bat_chg_total_Wh = 0;
|
|
dev_stat.bat_dis_total_Wh = 0;
|
|
hv_terminal.neg_energy_Wh = 0.0;
|
|
load.pos_energy_Wh = 0.0;
|
|
lv_terminal.pos_energy_Wh = 0.0;
|
|
lv_terminal.neg_energy_Wh = 0.0;
|
|
|
|
// set desired measurement values
|
|
adcval.bat_temperature = 25;
|
|
adcval.battery_voltage = 12;
|
|
adcval.dcdc_current = dcdc_current_sun;
|
|
adcval.internal_temperature = 25;
|
|
adcval.load_current = load_current;
|
|
adcval.internal_temperature = 25;
|
|
adcval.solar_voltage = 30;
|
|
|
|
// insert values into ADC functions
|
|
prepare_adc_readings(adcval);
|
|
prepare_adc_filtered();
|
|
daq_update();
|
|
|
|
for (int i = 0; i < 60*60*sun_hours; i++) {
|
|
hv_terminal.energy_balance();
|
|
lv_terminal.energy_balance();
|
|
load.energy_balance();
|
|
}
|
|
|
|
// disable DC/DC = solar charging
|
|
adcval.dcdc_current = 0;
|
|
prepare_adc_readings(adcval);
|
|
prepare_adc_filtered();
|
|
daq_update();
|
|
|
|
for (int i = 0; i < 60*60*night_hours; i++) {
|
|
hv_terminal.energy_balance();
|
|
lv_terminal.energy_balance();
|
|
load.energy_balance();
|
|
}
|
|
}
|
|
|
|
void charging_energy_calculation_valid()
|
|
{
|
|
energy_calculation_init();
|
|
// charging only during sun hours
|
|
TEST_ASSERT_EQUAL_FLOAT(round(sun_hours * lv_terminal.bus->voltage * (dcdc_current_sun - load_current)), round(lv_terminal.pos_energy_Wh));
|
|
}
|
|
|
|
void discharging_energy_calculation_valid()
|
|
{
|
|
energy_calculation_init();
|
|
// discharging (sum of current) only during dis hours
|
|
TEST_ASSERT_EQUAL_FLOAT(round(night_hours * lv_terminal.bus->voltage * adcval.load_current), round(lv_terminal.neg_energy_Wh));
|
|
}
|
|
|
|
void solar_input_energy_calculation_valid()
|
|
{
|
|
energy_calculation_init();
|
|
TEST_ASSERT_EQUAL_FLOAT(round(sun_hours * lv_terminal.bus->voltage * dcdc_current_sun), round(hv_terminal.neg_energy_Wh));
|
|
}
|
|
|
|
void load_output_energy_calculation_valid()
|
|
{
|
|
energy_calculation_init();
|
|
TEST_ASSERT_EQUAL_FLOAT(round((sun_hours + night_hours) * lv_terminal.bus->voltage * adcval.load_current), round(load.pos_energy_Wh));
|
|
}
|
|
|
|
void power_port_tests()
|
|
{
|
|
energy_calculation_init();
|
|
|
|
UNITY_BEGIN();
|
|
|
|
// energy calculation
|
|
RUN_TEST(charging_energy_calculation_valid);
|
|
RUN_TEST(discharging_energy_calculation_valid);
|
|
RUN_TEST(solar_input_energy_calculation_valid);
|
|
RUN_TEST(load_output_energy_calculation_valid);
|
|
|
|