* Copyright (c) 2016 Martin Jäger / Libre Solar
|
|
*
|
|
* SPDX-License-Identifier: Apache-2.0
|
|
*/
|
|
|
|
#ifndef DCDC_H
|
|
#define DCDC_H
|
|
|
|
/** @file
|
|
*
|
|
* @brief DC/DC buck/boost control functions
|
|
*/
|
|
|
|
#include <stdint.h>
|
|
#include <stdbool.h>
|
|
|
|
#include "power_port.h"
|
|
|
|
/** DC/DC basic operation mode
|
|
*
|
|
* Defines which type of device is connected to the high side and low side ports
|
|
*/
|
|
enum DcdcOperationMode
|
|
{
|
|
MODE_MPPT_BUCK, ///< solar panel at high side port, battery / load at low side port (typical MPPT)
|
|
MODE_MPPT_BOOST, ///< battery at high side port, solar panel at low side (e.g. e-bike charging)
|
|
MODE_NANOGRID ///< accept input power (if available and need for charging) or provide output power
|
|
///< (if no other power source on the grid and battery charged) on the high side port
|
|
///< and dis/charge battery on the low side port, battery voltage must be lower than
|
|
///< nano grid voltage.
|
|
};
|
|
|
|
/** DC/DC control state
|
|
*
|
|
* Allows to determine the current control state (off, CC, CV and MPPT)
|
|
*/
|
|
enum DcdcControlState
|
|
{
|
|
DCDC_STATE_OFF, ///< DC/DC switched off (low input power available or actively disabled)
|
|
DCDC_STATE_MPPT, ///< Maximum Power Point Tracking
|
|
DCDC_STATE_CC, ///< Constant-Current control
|
|
DCDC_STATE_CV, ///< Constant-Voltage control
|
|
DCDC_STATE_DERATING ///< Hardware-limits (current or temperature) reached
|
|
};
|
|
|
|
/** DC/DC class
|
|
*
|
|
* Contains all data belonging to the DC/DC sub-component of the PCB, incl.
|
|
* actual measurements and calibration parameters.
|
|
*/
|
|
class Dcdc
|
|
{
|
|
public:
|
|
/** Initialize DC/DC and DC/DC port structs
|
|
*
|
|
* See http://libre.solar/docs/dcdc_control for detailed information
|
|
*
|
|
* @param hv_side High voltage terminal (e.g. solar input for MPPT buck)
|
|
* @param lv_side Low voltage terminal (e.g. battery output for MPPT buck)
|
|
* @param mode Operation mode (buck, boost or nanogrid)
|
|
*/
|
|
Dcdc(PowerPort *hv_side, PowerPort* lv_side, DcdcOperationMode mode);
|
|
|
|
/** Check for valid start conditions of the DC/DC converter
|
|
*
|
|
* @returns 1 for buck mode, -1 for boost mode and 0 for invalid conditions
|
|
*/
|
|
int check_start_conditions();
|
|
|
|
/** Main control function for the DC/DC converter
|
|
*
|
|
* If DC/DC is off, this function checks start conditions and starts conversion if possible.
|
|
*/
|
|
void control();
|
|
|
|
/** Test mode for DC/DC, ramping up to 50% duty cycle
|
|
*/
|
|
void test();
|
|
|
|
/** Fast emergency stop function
|
|
*
|
|
* May be called from an ISR which detected overvoltage / overcurrent conditions
|
|
*/
|
|
void emergency_stop();
|
|
|
|
/** Prevent overcharging of battery in case of shorted HS MOSFET
|
|
*
|
|
* This function switches the LS MOSFET continuously on to blow the battery input fuse. The
|
|
* reason for self destruction should be logged and stored to EEPROM prior to calling this
|
|
* function, as the charge controller power supply will be cut after the fuse is destroyed.
|
|
*/
|
|
void self_destruction();
|
|
|
|
DcdcOperationMode mode; ///< DC/DC mode (buck, boost or nanogrid)
|
|
bool enabled; ///< Can be used to disable the DC/DC power stage
|
|
uint16_t state; ///< Control state (off / MPPT / CC / CV)
|
|
|
|
// actual measurements
|
|
PowerPort *hvs; ///< Pointer to DC bus at high voltage side
|
|
PowerPort *lvs; ///< Pointer to DC bus at low voltage (inductor) side
|
|
float temp_mosfets; ///< MOSFET temperature measurement (if existing)
|
|
|
|
// current state
|
|
float power_prev; ///< Stores previous conversion power (set via dcdc_control)
|
|
int pwm_delta; ///< Direction of PWM change for MPPT
|
|
int off_timestamp; ///< Last time the DC/DC was switched off
|
|
int power_good_timestamp; ///< Last time the DC/DC reached above minimum output power
|
|
|
|
// maximum allowed values
|
|
float ls_current_max; ///< Maximum low-side (inductor) current
|
|
float hs_voltage_max; ///< Maximum high-side voltage
|
|
float ls_voltage_max; ///< Maximum low-side voltage
|
|
float ls_voltage_min; ///< Minimum low-side voltage, e.g. for driver supply
|
|
float output_power_min; ///< Minimum output power (if lower, DC/DC is switched off)
|
|
|
|
// calibration parameters
|
|
unsigned int restart_interval; ///< Restart interval (s): When should we retry to start
|
|
///< charging after low output power cut-off?
|
|
|
|
private:
|
|
/** Calculates the duty cycle change depending on operating mode and actual measurements
|
|
*
|
|
* @returns duty cycle step (-1 or 1) or 0 if DC/DC should be switched off
|
|
*/
|
|
int duty_cycle_delta();
|
|
};
|
|
|
|
#endif /* DCDC_H */
|