Previous naming with chg/dis didn't make much sense e.g. for load output or solar panels. Voltage targets are now named with source or sink. Current limits are defined based on their direction (negative or positive). ASCII art graphic added for better explanation of passive sign convention.
136 lines
3.4 KiB
C++
136 lines
3.4 KiB
C++
|
|
#include "tests.h"
|
|
|
|
#include <time.h>
|
|
#include <stdio.h>
|
|
#include <math.h>
|
|
|
|
#include "main.h"
|
|
|
|
void reset_counters_at_start_of_day()
|
|
{
|
|
solar_terminal.voltage = bat_terminal.voltage - 1;
|
|
|
|
log_data.day_counter = 0;
|
|
|
|
solar_terminal.neg_energy_Wh = 10.0;
|
|
bat_terminal.neg_energy_Wh = 3.0;
|
|
bat_terminal.pos_energy_Wh = 4.0;
|
|
load_terminal.pos_energy_Wh = 9.0;
|
|
|
|
// 5 houurs without sun
|
|
for (int i = 0; i <= 5 * 60 * 60; i++) {
|
|
log_update_energy(&log_data);
|
|
}
|
|
|
|
TEST_ASSERT_EQUAL(10, log_data.solar_in_total_Wh);
|
|
TEST_ASSERT_EQUAL(3, log_data.bat_dis_total_Wh);
|
|
TEST_ASSERT_EQUAL(4, log_data.bat_chg_total_Wh);
|
|
TEST_ASSERT_EQUAL(9, log_data.load_out_total_Wh);
|
|
|
|
TEST_ASSERT_EQUAL(10, solar_terminal.neg_energy_Wh);
|
|
TEST_ASSERT_EQUAL(3, bat_terminal.neg_energy_Wh);
|
|
TEST_ASSERT_EQUAL(4, bat_terminal.pos_energy_Wh);
|
|
TEST_ASSERT_EQUAL(9, load_terminal.pos_energy_Wh);
|
|
|
|
// solar didn't come back yet
|
|
TEST_ASSERT_EQUAL(0, log_data.day_counter);
|
|
|
|
// now solar power comes back
|
|
solar_terminal.voltage = bat_terminal.voltage + 1;
|
|
log_update_energy(&log_data);
|
|
|
|
// day counter should be increased and daily energy counters reset
|
|
TEST_ASSERT_EQUAL(1, log_data.day_counter);
|
|
TEST_ASSERT_EQUAL(0, solar_terminal.neg_energy_Wh);
|
|
TEST_ASSERT_EQUAL(0, bat_terminal.neg_energy_Wh);
|
|
TEST_ASSERT_EQUAL(0, bat_terminal.pos_energy_Wh);
|
|
TEST_ASSERT_EQUAL(0, load_terminal.pos_energy_Wh);
|
|
}
|
|
|
|
void log_new_solar_voltage_max()
|
|
{
|
|
solar_terminal.voltage = 40;
|
|
log_update_min_max_values(&log_data);
|
|
TEST_ASSERT_EQUAL(40, log_data.solar_voltage_max);
|
|
}
|
|
|
|
void log_new_bat_voltage_max()
|
|
{
|
|
bat_terminal.voltage = 31;
|
|
log_update_min_max_values(&log_data);
|
|
TEST_ASSERT_EQUAL(31, log_data.battery_voltage_max);
|
|
}
|
|
|
|
void log_new_dcdc_current_max()
|
|
{
|
|
dcdc.lvs->current = 21;
|
|
log_update_min_max_values(&log_data);
|
|
TEST_ASSERT_EQUAL(21, log_data.dcdc_current_max);
|
|
}
|
|
|
|
void log_new_load_current_max()
|
|
{
|
|
load.port->current = 21;
|
|
log_update_min_max_values(&log_data);
|
|
TEST_ASSERT_EQUAL(21, log_data.load_current_max);
|
|
}
|
|
|
|
void log_solar_power_max()
|
|
{
|
|
solar_terminal.power = -50;
|
|
log_update_min_max_values(&log_data);
|
|
TEST_ASSERT_EQUAL(50, log_data.solar_power_max_day);
|
|
TEST_ASSERT_EQUAL(50, log_data.solar_power_max_total);
|
|
}
|
|
|
|
void log_load_power_max()
|
|
{
|
|
load.port->power = 50;
|
|
log_update_min_max_values(&log_data);
|
|
TEST_ASSERT_EQUAL(50, log_data.load_power_max_day);
|
|
TEST_ASSERT_EQUAL(50, log_data.load_power_max_total);
|
|
}
|
|
|
|
void log_new_mosfet_temp_max()
|
|
{
|
|
dcdc.temp_mosfets = 80;
|
|
log_update_min_max_values(&log_data);
|
|
TEST_ASSERT_EQUAL(80, log_data.mosfet_temp_max);
|
|
}
|
|
|
|
void log_new_bat_temp_max()
|
|
{
|
|
charger.bat_temperature = 45;
|
|
log_update_min_max_values(&log_data);
|
|
TEST_ASSERT_EQUAL(45, log_data.bat_temp_max);
|
|
}
|
|
|
|
extern float mcu_temp;
|
|
|
|
void log_new_int_temp_max()
|
|
{
|
|
mcu_temp = 22;
|
|
log_update_min_max_values(&log_data);
|
|
TEST_ASSERT_EQUAL(22, log_data.int_temp_max);
|
|
}
|
|
|
|
void log_tests()
|
|
{
|
|
UNITY_BEGIN();
|
|
|
|
RUN_TEST(reset_counters_at_start_of_day);
|
|
|
|
RUN_TEST(log_new_solar_voltage_max);
|
|
RUN_TEST(log_new_bat_voltage_max);
|
|
RUN_TEST(log_new_dcdc_current_max);
|
|
RUN_TEST(log_new_load_current_max);
|
|
RUN_TEST(log_solar_power_max);
|
|
RUN_TEST(log_load_power_max);
|
|
RUN_TEST(log_new_mosfet_temp_max);
|
|
RUN_TEST(log_new_bat_temp_max);
|
|
RUN_TEST(log_new_int_temp_max);
|
|
|
|
UNITY_END();
|
|
}
|