// PWM charge controller
|
|
#define CONFIG_PWM_TERMINAL_SOLAR 1
|
|
|
|
// MPPT buck/boost or nanogrid mode
|
|
#define CONFIG_HV_TERMINAL_SOLAR 1
|
|
#define CONFIG_HV_TERMINAL_NANOGRID 0
|
|
|
|
// battery always assumed to be at low-voltage terminal (might need to be changed for boost mode)
|
|
#define CONFIG_LV_TERMINAL_BATTERY 1
|
|
|
|
#define CONFIG_THINGSET_EXPERT_PASSWORD "expert123"
|
|
#define CONFIG_THINGSET_MAKER_PASSWORD "maker456"
|
|
|
|
// Values that are otherwise defined by Kconfig
|
|
#define CONFIG_CONTROL_FREQUENCY 10 // Hz
|
|
|
|
#define CONFIG_BAT_TYPE_GEL 1
|
|
#define CONFIG_BAT_TYPE 2
|
|
#define CONFIG_BAT_CAPACITY_AH 50
|
|
#define CONFIG_BAT_NUM_CELLS 6
|
|
#define CONFIG_CELL_ABS_MAX_VOLTAGE_MV 2450
|
|
#define CONFIG_CELL_TOPPING_VOLTAGE_MV 2400
|
|
#define CONFIG_CELL_RECHARGE_VOLTAGE_MV 2300
|
|
#define CONFIG_CELL_RECONNECT_VOLTAGE_MV 2100
|
|
#define CONFIG_CELL_DISCONNECT_VOLTAGE_MV 1950
|
|
#define CONFIG_CELL_ABS_MIN_VOLTAGE_MV 1600
|
|
#define CONFIG_CELL_OCV_FULL_MV 2150
|
|
#define CONFIG_CELL_OCV_EMPTY_MV 1900
|
|
#define CONFIG_CELL_TRICKLE 1
|
|
#define CONFIG_CELL_TRICKLE_VOLTAGE_MV 2300
|
|
#define CONFIG_CELL_TRICKLE_RECHARGE_TIME 1800
|
|
#define CONFIG_CELL_EQUALIZATION_VOLTAGE_MV 2450
|
|
#define CONFIG_CELL_EQUALIZATION_DURATION 3600
|
|
#define CONFIG_CELL_EQUALIZATION_TRIGGER_DAYS 60
|
|
#define CONFIG_CELL_EQUALIZATION_TRIGGER_DEEP_CYCLES 10
|
|
#define CONFIG_CELL_TEMP_COMPENSATION_MV_K -3
|
|
#define CONFIG_CELL_INTERNAL_RESISTANCE_MOHM 5
|
|
#define CONFIG_BAT_CHARGE_TEMP_MAX 50
|
|
#define CONFIG_BAT_CHARGE_TEMP_MIN 0
|
|
#define CONFIG_BAT_DISCHARGE_TEMP_MAX 50
|
|
#define CONFIG_BAT_DISCHARGE_TEMP_MIN -10
|
|
#define CONFIG_LOAD_OC_RECOVERY_DELAY 300
|
|
#define CONFIG_LOAD_LVD_RECOVERY_DELAY 300
|