Replaces previous "switch" and "pwm-out" bindings and allows to reference either gpio or pwm handle and specify maximum current. Also replacing CONFIG_HAS_LOAD and CONFIG_HAS_USB_PWR with DT_ variants.
154 lines
4.8 KiB
C++
154 lines
4.8 KiB
C++
/*
|
|
* Copyright (c) 2016 Martin Jäger / Libre Solar
|
|
*
|
|
* SPDX-License-Identifier: Apache-2.0
|
|
*/
|
|
|
|
#include "load.h"
|
|
|
|
#ifndef UNIT_TEST
|
|
#include <zephyr.h>
|
|
#endif
|
|
|
|
#include "board.h"
|
|
#include "leds.h"
|
|
#include "device_status.h"
|
|
#include "debug.h"
|
|
#include "helper.h"
|
|
|
|
extern DeviceStatus dev_stat;
|
|
|
|
LoadOutput::LoadOutput(DcBus *dc_bus, void (*drv_switch_fn)(bool), void (*drv_init_fn)()) :
|
|
PowerPort(dc_bus),
|
|
switch_set(drv_switch_fn)
|
|
{
|
|
state = LOAD_STATE_OFF;
|
|
|
|
// call driver initialization function
|
|
drv_init_fn();
|
|
|
|
switch_set(false);
|
|
junction_temperature = 25; // starting point: 25°C
|
|
oc_recovery_delay = 5*60; // default: 5 minutes
|
|
lvd_recovery_delay = 60*60; // default: 1 hour
|
|
ov_hysteresis = 0.3;
|
|
|
|
enable = true; // switch on in next control() call if everything is fine
|
|
}
|
|
|
|
// this function is called more often than the state machine
|
|
void LoadOutput::control()
|
|
{
|
|
if (state == LOAD_STATE_ON) {
|
|
|
|
// junction temperature calculation model for overcurrent detection
|
|
junction_temperature = junction_temperature + (
|
|
dev_stat.internal_temp - junction_temperature + current * current /
|
|
(DT_OUTPUTS_LOAD_CURRENT_MAX * DT_OUTPUTS_LOAD_CURRENT_MAX) *
|
|
(DT_CHARGE_CONTROLLER_PCB_MOSFETS_TJ_MAX - DT_CHARGE_CONTROLLER_PCB_INTERNAL_TREF_MAX)
|
|
) / (DT_CHARGE_CONTROLLER_PCB_MOSFETS_TAU_JA * CONFIG_CONTROL_FREQUENCY);
|
|
|
|
if (junction_temperature > DT_CHARGE_CONTROLLER_PCB_MOSFETS_TJ_MAX ||
|
|
current > DT_OUTPUTS_LOAD_CURRENT_MAX * 2)
|
|
{
|
|
flags_set(&error_flags, ERR_LOAD_OVERCURRENT);
|
|
oc_timestamp = uptime();
|
|
}
|
|
|
|
// negative margin means sourcing current from bus is allowed
|
|
if (bus->src_current_margin > -0.1F) {
|
|
flags_set(&error_flags, ERR_LOAD_BUS_SRC_CURRENT);
|
|
}
|
|
|
|
if (bus->voltage < bus->src_control_voltage(disconnect_voltage)) {
|
|
flags_set(&error_flags, ERR_LOAD_SHEDDING);
|
|
lvd_timestamp = uptime();
|
|
}
|
|
|
|
// long-term overvoltage (overvoltage transients are detected as an ADC alert and switch
|
|
// off the solar input instead of the load output)
|
|
if (bus->voltage > overvoltage || bus->voltage >
|
|
DT_CHARGE_CONTROLLER_PCB_LS_VOLTAGE_MAX)
|
|
{
|
|
ov_debounce_counter++;
|
|
if (ov_debounce_counter > CONFIG_CONTROL_FREQUENCY) {
|
|
// waited 1s before setting the flag
|
|
flags_set(&error_flags, ERR_LOAD_OVERVOLTAGE);
|
|
}
|
|
}
|
|
else {
|
|
ov_debounce_counter = 0;
|
|
}
|
|
|
|
if (error_flags) {
|
|
stop();
|
|
}
|
|
|
|
if (enable == false) {
|
|
switch_set(false);
|
|
state = LOAD_STATE_OFF;
|
|
}
|
|
}
|
|
else {
|
|
// load is off: check if errors are resolved and if load can be switched on
|
|
|
|
if (flags_check(&error_flags, ERR_LOAD_SHEDDING) &&
|
|
bus->voltage > bus->src_control_voltage(reconnect_voltage) &&
|
|
uptime() - lvd_timestamp > lvd_recovery_delay)
|
|
{
|
|
flags_clear(&error_flags, ERR_LOAD_SHEDDING);
|
|
}
|
|
|
|
if (flags_check(&error_flags, ERR_LOAD_OVERCURRENT | ERR_LOAD_VOLTAGE_DIP) &&
|
|
uptime() - oc_timestamp > oc_recovery_delay)
|
|
{
|
|
flags_clear(&error_flags, ERR_LOAD_OVERCURRENT | ERR_LOAD_VOLTAGE_DIP);
|
|
}
|
|
|
|
if (flags_check(&error_flags, ERR_LOAD_OVERVOLTAGE) &&
|
|
bus->voltage < (overvoltage - ov_hysteresis) &&
|
|
bus->voltage < (DT_CHARGE_CONTROLLER_PCB_LS_VOLTAGE_MAX - ov_hysteresis))
|
|
{
|
|
flags_clear(&error_flags, ERR_LOAD_OVERVOLTAGE);
|
|
}
|
|
|
|
if (flags_check(&error_flags, ERR_LOAD_SHORT_CIRCUIT) && enable == false) {
|
|
// stay here until the charge controller is reset or load is manually switched off
|
|
flags_clear(&error_flags, ERR_LOAD_SHORT_CIRCUIT);
|
|
}
|
|
|
|
// finally switch on if all errors were resolved and at least 1A src current is available
|
|
if (enable == true && !error_flags && bus->src_current_margin < -1.0F) {
|
|
switch_set(true);
|
|
state = LOAD_STATE_ON;
|
|
}
|
|
}
|
|
|
|
info = error_flags > 0 ? -error_flags : state;
|
|
}
|
|
|
|
void LoadOutput::stop(uint32_t flag)
|
|
{
|
|
switch_set(false);
|
|
state = LOAD_STATE_OFF;
|
|
flags_set(&error_flags, flag);
|
|
|
|
// flicker the load LED if failure was most probably caused by the user
|
|
if (flags_check(&error_flags,
|
|
ERR_LOAD_OVERCURRENT | ERR_LOAD_VOLTAGE_DIP | ERR_LOAD_SHORT_CIRCUIT))
|
|
{
|
|
#ifdef LED_LOAD
|
|
leds_flicker(LED_LOAD);
|
|
#endif
|
|
oc_timestamp = uptime();
|
|
}
|
|
}
|
|
|
|
void LoadOutput::set_voltage_limits(float lvd, float lvr, float ov)
|
|
{
|
|
disconnect_voltage = lvd;
|
|
reconnect_voltage = lvr;
|
|
|
|
overvoltage = ov;
|
|
}
|