Files
charge-controller-firmware/app/src/pwm_switch.cpp
T
Martin Jäger 8ab8ea244a Move to standard Zephyr T2 workspace structure (star topology)
https://docs.zephyrproject.org/latest/guides/west/workspaces.html

Previously, west manifest and CMake entry point were in zephyr subfolder
as required for PlatformIO. As PlatformIO support was dropped, we can
follow the default Zephyr folder structure more closely.

The application is built and flashed from app subfolder, where as unit
tests are run from tests subfolder.
2021-12-12 14:09:05 +01:00

161 lines
5.1 KiB
C++

/*
* Copyright (c) The Libre Solar Project Contributors
*
* SPDX-License-Identifier: Apache-2.0
*/
#include "pwm_switch.h"
#include <zephyr.h>
#include <stdio.h>
#include <time.h>
#include "mcu.h"
#include "daq.h"
#include "helper.h"
#include "setup.h"
LOG_MODULE_REGISTER(pwm_switch, CONFIG_PWM_LOG_LEVEL);
#if BOARD_HAS_PWM_PORT
#define PWM_CURRENT_MAX (DT_PROP(DT_CHILD(DT_PATH(outputs), pwm_switch), current_max))
#define PWM_PERIOD (DT_PHA(DT_CHILD(DT_PATH(outputs), pwm_switch), pwms, period))
bool PwmSwitch::active()
{
return pwm_active();
}
bool PwmSwitch::signal_high()
{
return pwm_signal_high();
}
PwmSwitch::PwmSwitch(DcBus *dc_bus) :
PowerPort(dc_bus)
{
// period stored in nanoseconds
pwm_signal_init_registers(1000 * 1000 * 1000 / PWM_PERIOD);
}
void PwmSwitch::test()
{
if (pwm_active() && enable == false) {
pwm_signal_stop();
off_timestamp = uptime();
LOG_INF("PWM test mode stop.");
}
else if (!pwm_active() && enable == true) {
// turning the PWM switch on creates a short voltage rise, so inhibit alerts by 50 ms
adc_upper_alert_inhibit(ADC_POS(v_low), 50);
pwm_signal_start(0.9F);
LOG_INF("PWM test mode start.");
}
}
void PwmSwitch::control()
{
if (pwm_active()) {
if (current < -0.1F) {
power_good_timestamp = uptime(); // reset the time
}
if (neg_current_limit == 0
|| (uptime() - power_good_timestamp > 10) // low power since 10s
|| current > 0.5F // discharging battery into solar panel --> stop
|| bus->voltage < 9.0F // not enough voltage for MOSFET drivers anymore
|| enable == false)
{
pwm_signal_stop();
off_timestamp = uptime();
LOG_INF("PWM charger stop, current = %d mA", (int)(current * 1000.0F));
}
else if (bus->voltage > bus->sink_control_voltage() + 0.3F) {
pwm_signal_stop();
off_timestamp = uptime();
dev_stat.set_error(ERR_PWM_SWITCH_OVERVOLTAGE);
LOG_INF("PWM charger stop, overvoltage.");
}
else if (bus->voltage > bus->sink_control_voltage() // bus voltage above target
|| current < neg_current_limit // port current limit exceeded
|| current < -PWM_CURRENT_MAX) // PCB current limit exceeded
{
// decrease power, as limits were reached
// the gate driver switch-off time is quite high (fall time around 1ms), so very short
// on or off periods (duty cycle close to 0 and 1) should be avoided
if (pwm_signal_get_duty_cycle() > 0.95F) {
// prevent very short off periods
pwm_signal_set_duty_cycle(0.95F);
}
else if (pwm_signal_get_duty_cycle() < 0.05F) {
// prevent very short on periods and switch completely off instead
pwm_signal_stop();
off_timestamp = uptime();
// consider this as overvoltage in order to start again with 5% duty cycle
dev_stat.set_error(ERR_PWM_SWITCH_OVERVOLTAGE);
LOG_INF("PWM charger stop, no further derating possible.");
}
else {
// decrease the power with large steps to prevent long-term overvoltages if
// the PWM switch was started with full battery and high solar irradiation
pwm_signal_duty_cycle_step(-10);
}
}
else {
// increase power (if not yet at 100% duty cycle)
if (pwm_signal_get_duty_cycle() > 0.95F) {
// prevent very short off periods and switch completely on instead
pwm_signal_set_duty_cycle(1);
}
else {
pwm_signal_duty_cycle_step(1);
}
}
if (dev_stat.has_error(ERR_PWM_SWITCH_OVERVOLTAGE) &&
bus->voltage < bus->sink_control_voltage() - 0.5F)
{
dev_stat.clear_error(ERR_PWM_SWITCH_OVERVOLTAGE);
}
}
else {
if (bus->sink_current_margin > 0 // charging allowed
&& bus->voltage < bus->sink_control_voltage()
&& ext_voltage > bus->voltage + offset_voltage_start
&& uptime() > (off_timestamp + restart_interval)
&& enable == true)
{
// turning the PWM switch on creates a short voltage rise, so inhibit alerts by 50 ms
adc_upper_alert_inhibit(ADC_POS(v_low), 50);
if (dev_stat.has_error(ERR_PWM_SWITCH_OVERVOLTAGE)) {
// start with minimum duty cycle in order to prevent another overvoltage event
pwm_signal_start(0.05F);
}
else {
pwm_signal_start(1.0F);
}
power_good_timestamp = uptime();
LOG_INF("PWM charger start.");
}
}
}
void PwmSwitch::stop()
{
pwm_signal_stop();
off_timestamp = uptime();
}
float PwmSwitch::get_duty_cycle()
{
return pwm_signal_get_duty_cycle();
}
#endif /* BOARD_HAS_PWM_PORT */