https://docs.zephyrproject.org/latest/guides/west/workspaces.html Previously, west manifest and CMake entry point were in zephyr subfolder as required for PlatformIO. As PlatformIO support was dropped, we can follow the default Zephyr folder structure more closely. The application is built and flashed from app subfolder, where as unit tests are run from tests subfolder.
644 lines
27 KiB
C++
644 lines
27 KiB
C++
/*
|
|
* Copyright (c) The Libre Solar Project Contributors
|
|
*
|
|
* SPDX-License-Identifier: Apache-2.0
|
|
*/
|
|
|
|
#include "bat_charger.h"
|
|
|
|
#include <zephyr.h>
|
|
|
|
#include <logging/log.h>
|
|
LOG_MODULE_REGISTER(bat_charger, CONFIG_BAT_LOG_LEVEL);
|
|
|
|
#include <math.h> // for fabs function
|
|
#include <stdio.h>
|
|
|
|
#include "board.h"
|
|
#include "helper.h"
|
|
#include "device_status.h"
|
|
|
|
extern DeviceStatus dev_stat;
|
|
extern LoadOutput load;
|
|
|
|
// DISCHARGE_CURRENT_MAX used to estimate current-compensation of load disconnect voltage
|
|
#if BOARD_HAS_LOAD_OUTPUT
|
|
#define DISCHARGE_CURRENT_MAX DT_PROP(DT_CHILD(DT_PATH(outputs), load), current_max)
|
|
#else
|
|
#define DISCHARGE_CURRENT_MAX DT_PROP(DT_PATH(pcb), dcdc_current_max)
|
|
#endif
|
|
|
|
void battery_conf_init(BatConf *bat, int type, int num_cells, float nominal_capacity)
|
|
{
|
|
bat->nominal_capacity = nominal_capacity;
|
|
|
|
// 1C should be safe for all batteries
|
|
bat->charge_current_max = bat->nominal_capacity;
|
|
bat->discharge_current_max = bat->nominal_capacity;
|
|
|
|
bat->time_limit_recharge = 60; // sec
|
|
bat->topping_duration = 120*60; // sec
|
|
|
|
bat->charge_temp_max = 50;
|
|
bat->charge_temp_min = -10;
|
|
bat->discharge_temp_max = 50;
|
|
bat->discharge_temp_min = -10;
|
|
|
|
switch (type)
|
|
{
|
|
case BAT_TYPE_FLOODED:
|
|
case BAT_TYPE_AGM:
|
|
case BAT_TYPE_GEL:
|
|
bat->absolute_max_voltage = static_cast<float>(num_cells) * 2.45F;
|
|
bat->topping_voltage = static_cast<float>(num_cells) * 2.4F;
|
|
bat->recharge_voltage = static_cast<float>(num_cells) * 2.2F;
|
|
|
|
// Cell-level thresholds based on EN 62509:2011 (both thresholds current-compensated)
|
|
bat->load_disconnect_voltage = static_cast<float>(num_cells) * 1.95F;
|
|
bat->load_reconnect_voltage = static_cast<float>(num_cells) * 2.10F;
|
|
|
|
// assumption: Battery selection matching charge controller
|
|
bat->internal_resistance = static_cast<float>(num_cells) * (1.95F - 1.80F) /
|
|
DISCHARGE_CURRENT_MAX;
|
|
|
|
bat->absolute_min_voltage = static_cast<float>(num_cells) * 1.6F;
|
|
|
|
// Voltages during idle (no charging/discharging current)
|
|
bat->ocv_full = static_cast<float>(num_cells) *
|
|
((type == BAT_TYPE_FLOODED) ? 2.10F : 2.15F);
|
|
bat->ocv_empty = static_cast<float>(num_cells) * 1.90F;
|
|
|
|
// https://batteryuniversity.com/learn/article/charging_the_lead_acid_battery
|
|
bat->topping_cutoff_current = bat->nominal_capacity * 0.04F; // 3-5 % of C/1
|
|
|
|
bat->float_enabled = true;
|
|
bat->float_recharge_time = 30*60;
|
|
// Values as suggested in EN 62509:2011
|
|
bat->float_voltage = static_cast<float>(num_cells) *
|
|
((type == BAT_TYPE_FLOODED) ? 2.35F : 2.3F);
|
|
|
|
// Enable for flooded batteries only, according to
|
|
// https://discoverbattery.com/battery-101/equalizing-flooded-batteries-only
|
|
bat->equalization_enabled = false;
|
|
// Values as suggested in EN 62509:2011
|
|
bat->equalization_voltage = static_cast<float>(num_cells) *
|
|
((type == BAT_TYPE_FLOODED) ? 2.50F : 2.45F);
|
|
bat->equalization_duration = 60*60;
|
|
bat->equalization_current_limit = (1.0F / 7.0F) * bat->nominal_capacity;
|
|
bat->equalization_trigger_days = 60;
|
|
bat->equalization_trigger_deep_cycles = 10;
|
|
|
|
bat->temperature_compensation = -0.003F; // -3 mV/°C/cell
|
|
break;
|
|
|
|
case BAT_TYPE_LFP:
|
|
bat->absolute_max_voltage = static_cast<float>(num_cells) * 3.60F;
|
|
bat->topping_voltage = static_cast<float>(num_cells) * 3.55F; // CV voltage
|
|
bat->recharge_voltage = static_cast<float>(num_cells) * 3.35F;
|
|
|
|
bat->load_disconnect_voltage = static_cast<float>(num_cells) * 3.00F;
|
|
bat->load_reconnect_voltage = static_cast<float>(num_cells) * 3.15F;
|
|
|
|
// 5% voltage drop at max current
|
|
bat->internal_resistance = bat->load_disconnect_voltage * 0.05F /
|
|
DISCHARGE_CURRENT_MAX;
|
|
bat->absolute_min_voltage = static_cast<float>(num_cells) * 2.0F;
|
|
|
|
// will give really nonlinear SOC calculation because of flat OCV of LFP cells...
|
|
bat->ocv_full = static_cast<float>(num_cells) * 3.4F;
|
|
bat->ocv_empty = static_cast<float>(num_cells) * 3.0F;
|
|
|
|
// C/10 cut-off at end of CV phase by default
|
|
bat->topping_cutoff_current = bat->nominal_capacity / 10;
|
|
|
|
bat->float_enabled = false;
|
|
bat->equalization_enabled = false;
|
|
bat->temperature_compensation = 0;
|
|
bat->charge_temp_min = 0;
|
|
break;
|
|
|
|
case BAT_TYPE_NMC:
|
|
case BAT_TYPE_NMC_HV:
|
|
bat->topping_voltage = static_cast<float>(num_cells) *
|
|
((type == BAT_TYPE_NMC_HV) ? 4.35F : 4.20F);
|
|
bat->absolute_max_voltage = bat->topping_voltage +
|
|
static_cast<float>(num_cells) * 0.05F;
|
|
bat->recharge_voltage = static_cast<float>(num_cells) * 3.9F;
|
|
|
|
bat->load_disconnect_voltage = static_cast<float>(num_cells) * 3.3F;
|
|
bat->load_reconnect_voltage = static_cast<float>(num_cells) * 3.6F;
|
|
|
|
// 5% voltage drop at max current
|
|
bat->internal_resistance = bat->load_disconnect_voltage * 0.05F /
|
|
DISCHARGE_CURRENT_MAX;
|
|
|
|
bat->absolute_min_voltage = static_cast<float>(num_cells) * 2.5F;
|
|
|
|
bat->ocv_full = static_cast<float>(num_cells) * 4.0F;
|
|
bat->ocv_empty = static_cast<float>(num_cells) * 3.0F;
|
|
|
|
// C/10 cut-off at end of CV phase by default
|
|
bat->topping_cutoff_current = bat->nominal_capacity / 10;
|
|
|
|
bat->float_enabled = false;
|
|
bat->equalization_enabled = false;
|
|
bat->temperature_compensation = 0;
|
|
bat->charge_temp_min = 0;
|
|
break;
|
|
|
|
case BAT_TYPE_CUSTOM:
|
|
#ifdef CONFIG_BAT_TYPE_CUSTOM
|
|
bat->absolute_max_voltage = 0.001F *
|
|
static_cast<float>(CONFIG_BAT_NUM_CELLS * CONFIG_CELL_ABS_MAX_VOLTAGE_MV);
|
|
|
|
bat->topping_voltage = 0.001F *
|
|
static_cast<float>(CONFIG_BAT_NUM_CELLS * CONFIG_CELL_TOPPING_VOLTAGE_MV);
|
|
|
|
bat->recharge_voltage = 0.001F *
|
|
static_cast<float>(CONFIG_BAT_NUM_CELLS * CONFIG_CELL_RECHARGE_VOLTAGE_MV);
|
|
|
|
bat->load_disconnect_voltage = 0.001F *
|
|
static_cast<float>(CONFIG_BAT_NUM_CELLS * CONFIG_CELL_DISCONNECT_VOLTAGE_MV);
|
|
bat->load_reconnect_voltage = 0.001F *
|
|
static_cast<float>(CONFIG_BAT_NUM_CELLS * CONFIG_CELL_RECONNECT_VOLTAGE_MV);
|
|
|
|
bat->internal_resistance = 0.001F *
|
|
static_cast<float>(CONFIG_BAT_NUM_CELLS * CONFIG_CELL_INTERNAL_RESISTANCE_MOHM);
|
|
|
|
bat->absolute_min_voltage = 0.001F *
|
|
static_cast<float>(CONFIG_BAT_NUM_CELLS * CONFIG_CELL_ABS_MIN_VOLTAGE_MV);
|
|
|
|
// Voltages during idle (no charging/discharging current)
|
|
bat->ocv_full = 0.001F *
|
|
static_cast<float>(CONFIG_BAT_NUM_CELLS * CONFIG_CELL_OCV_FULL_MV);
|
|
bat->ocv_empty = 0.001F *
|
|
static_cast<float>(CONFIG_BAT_NUM_CELLS * CONFIG_CELL_OCV_EMPTY_MV);
|
|
|
|
// https://batteryuniversity.com/learn/article/charging_the_lead_acid_battery
|
|
bat->topping_cutoff_current = bat->nominal_capacity * 0.04F; // 3-5 % of C/1
|
|
|
|
bat->float_enabled = IS_ENABLED(CONFIG_CELL_FLOAT);
|
|
bat->float_recharge_time = CONFIG_CELL_FLOAT_RECHARGE_TIME;
|
|
bat->float_voltage = 0.001F *
|
|
static_cast<float>(CONFIG_BAT_NUM_CELLS * CONFIG_CELL_FLOAT_VOLTAGE_MV);
|
|
|
|
bat->equalization_enabled = IS_ENABLED(CONFIG_CELL_EQUALIZATION);
|
|
bat->equalization_voltage = 0.001F *
|
|
static_cast<float>(CONFIG_BAT_NUM_CELLS * CONFIG_CELL_EQUALIZATION_VOLTAGE_MV);
|
|
bat->equalization_duration = CONFIG_CELL_EQUALIZATION_DURATION;
|
|
bat->equalization_current_limit = (1.0F / 7.0F) * bat->nominal_capacity;
|
|
bat->equalization_trigger_days = CONFIG_CELL_EQUALIZATION_TRIGGER_DAYS;
|
|
bat->equalization_trigger_deep_cycles = CONFIG_CELL_EQUALIZATION_TRIGGER_DEEP_CYCLES;
|
|
|
|
bat->temperature_compensation = 0.001F *
|
|
static_cast<float>(CONFIG_BAT_NUM_CELLS * CONFIG_CELL_TEMP_COMPENSATION_MV_K);
|
|
|
|
bat->charge_temp_max = CONFIG_BAT_CHARGE_TEMP_MAX;
|
|
bat->charge_temp_min = CONFIG_BAT_CHARGE_TEMP_MIN;
|
|
bat->discharge_temp_max = CONFIG_BAT_DISCHARGE_TEMP_MAX;
|
|
bat->discharge_temp_min = CONFIG_BAT_DISCHARGE_TEMP_MIN;
|
|
#else
|
|
LOG_ERR("Custom battery type cannot be initialized at runtime.");
|
|
#endif
|
|
break;
|
|
}
|
|
}
|
|
|
|
// checks settings in bat_conf for plausibility
|
|
bool battery_conf_check(BatConf *bat_conf)
|
|
{
|
|
// things to check:
|
|
// - load_disconnect/reconnect hysteresis makes sense?
|
|
// - cutoff current not extremely low/high
|
|
// - capacity plausible
|
|
|
|
LOG_DBG("battery_conf_check: %d %d %d %d %d %d %d",
|
|
bat_conf->load_reconnect_voltage > (bat_conf->load_disconnect_voltage + 0.6),
|
|
bat_conf->recharge_voltage < (bat_conf->topping_voltage - 0.4),
|
|
bat_conf->recharge_voltage > (bat_conf->load_disconnect_voltage + 1),
|
|
bat_conf->load_disconnect_voltage > (bat_conf->absolute_min_voltage + 0.4),
|
|
bat_conf->topping_cutoff_current < (bat_conf->nominal_capacity / 10.0),
|
|
bat_conf->topping_cutoff_current > 0.01,
|
|
(bat_conf->float_enabled == false ||
|
|
(bat_conf->float_voltage < bat_conf->topping_voltage &&
|
|
bat_conf->float_voltage > bat_conf->load_disconnect_voltage))
|
|
);
|
|
|
|
return (
|
|
bat_conf->load_reconnect_voltage > (bat_conf->load_disconnect_voltage + 0.4) &&
|
|
bat_conf->recharge_voltage < (bat_conf->topping_voltage - 0.4) &&
|
|
bat_conf->recharge_voltage > (bat_conf->load_disconnect_voltage + 1) &&
|
|
bat_conf->load_disconnect_voltage > (bat_conf->absolute_min_voltage + 0.4) &&
|
|
// max. 10% drop
|
|
bat_conf->internal_resistance < bat_conf->load_disconnect_voltage * 0.1 /
|
|
DISCHARGE_CURRENT_MAX &&
|
|
// max. 3% loss
|
|
bat_conf->wire_resistance < bat_conf->topping_voltage * 0.03 / DISCHARGE_CURRENT_MAX &&
|
|
// C/10 or lower current cutoff allowed
|
|
bat_conf->topping_cutoff_current < (bat_conf->nominal_capacity / 10.0) &&
|
|
bat_conf->topping_cutoff_current > 0.01 &&
|
|
(bat_conf->float_enabled == false ||
|
|
(bat_conf->float_voltage < bat_conf->topping_voltage &&
|
|
bat_conf->float_voltage > bat_conf->load_disconnect_voltage))
|
|
);
|
|
}
|
|
|
|
void battery_conf_overwrite(BatConf *source, BatConf *destination, Charger *charger)
|
|
{
|
|
// TODO: stop DC/DC
|
|
|
|
destination->topping_voltage = source->topping_voltage;
|
|
destination->recharge_voltage = source->recharge_voltage;
|
|
destination->load_reconnect_voltage = source->load_reconnect_voltage;
|
|
destination->load_disconnect_voltage = source->load_disconnect_voltage;
|
|
destination->absolute_max_voltage = source->absolute_max_voltage;
|
|
destination->absolute_min_voltage = source->absolute_min_voltage;
|
|
destination->charge_current_max = source->charge_current_max;
|
|
destination->topping_cutoff_current = source->topping_cutoff_current;
|
|
destination->topping_duration = source->topping_duration;
|
|
destination->float_enabled = source->float_enabled;
|
|
destination->float_voltage = source->float_voltage;
|
|
destination->float_recharge_time = source->float_recharge_time;
|
|
destination->charge_temp_max = source->charge_temp_max;
|
|
destination->charge_temp_min = source->charge_temp_min;
|
|
destination->discharge_temp_max = source->discharge_temp_max;
|
|
destination->discharge_temp_min = source->discharge_temp_min;
|
|
destination->temperature_compensation = source->temperature_compensation;
|
|
destination->internal_resistance = source->internal_resistance;
|
|
destination->wire_resistance = source->wire_resistance;
|
|
|
|
// reset Ah counter and SOH if battery nominal capacity was changed
|
|
if (destination->nominal_capacity != source->nominal_capacity) {
|
|
destination->nominal_capacity = source->nominal_capacity;
|
|
if (charger != NULL) {
|
|
charger->discharged_Ah = 0;
|
|
charger->usable_capacity = 0;
|
|
charger->soh = 0;
|
|
}
|
|
}
|
|
|
|
// TODO:
|
|
// - update also DC/DC etc. (now this function only works at system startup)
|
|
// - restart DC/DC
|
|
}
|
|
|
|
bool battery_conf_changed(BatConf *a, BatConf *b)
|
|
{
|
|
return (
|
|
a->topping_voltage != b->topping_voltage ||
|
|
a->recharge_voltage != b->recharge_voltage ||
|
|
a->load_reconnect_voltage != b->load_reconnect_voltage ||
|
|
a->load_disconnect_voltage != b->load_disconnect_voltage ||
|
|
a->absolute_max_voltage != b->absolute_max_voltage ||
|
|
a->absolute_min_voltage != b->absolute_min_voltage ||
|
|
a->charge_current_max != b->charge_current_max ||
|
|
a->topping_cutoff_current != b->topping_cutoff_current ||
|
|
a->topping_duration != b->topping_duration ||
|
|
a->float_enabled != b->float_enabled ||
|
|
a->float_voltage != b->float_voltage ||
|
|
a->float_recharge_time != b->float_recharge_time ||
|
|
a->charge_temp_max != b->charge_temp_max ||
|
|
a->charge_temp_min != b->charge_temp_min ||
|
|
a->discharge_temp_max != b->discharge_temp_max ||
|
|
a->discharge_temp_min != b->discharge_temp_min ||
|
|
a->temperature_compensation != b->temperature_compensation ||
|
|
a->internal_resistance != b->internal_resistance ||
|
|
a->wire_resistance != b->wire_resistance
|
|
);
|
|
}
|
|
|
|
void Charger::detect_num_batteries(BatConf *bat) const
|
|
{
|
|
if (port->bus->voltage > bat->absolute_min_voltage * 2 &&
|
|
port->bus->voltage < bat->absolute_max_voltage * 2)
|
|
{
|
|
port->bus->series_multiplier = 2;
|
|
printf("Detected two batteries (total %.2f V max)\n", bat->topping_voltage * 2);
|
|
}
|
|
else {
|
|
printf("Detected single battery (%.2f V max)\n", bat->topping_voltage);
|
|
}
|
|
}
|
|
|
|
void Charger::update_soc(BatConf *bat_conf)
|
|
{
|
|
static int soc_filtered = 0; // SOC / 100 for better filtering
|
|
|
|
if (fabs(port->current) < 0.2) {
|
|
int soc_new = (int)((port->bus->voltage - bat_conf->ocv_empty) /
|
|
(bat_conf->ocv_full - bat_conf->ocv_empty) * 10000.0);
|
|
|
|
if (soc_new > 500 && soc_filtered == 0) {
|
|
// bypass filter during initialization
|
|
soc_filtered = soc_new;
|
|
}
|
|
else {
|
|
// filtering to adjust SOC very slowly
|
|
soc_filtered += (soc_new - soc_filtered) / 100;
|
|
}
|
|
|
|
if (soc_filtered > 10000) {
|
|
soc_filtered = 10000;
|
|
}
|
|
else if (soc_filtered < 0) {
|
|
soc_filtered = 0;
|
|
}
|
|
soc = soc_filtered / 100;
|
|
}
|
|
|
|
discharged_Ah += -port->current / 3600.0F; // charged current is positive: change sign
|
|
}
|
|
|
|
void Charger::enter_state(int next_state)
|
|
{
|
|
LOG_DBG("Enter State: %d", next_state);
|
|
time_state_changed = uptime();
|
|
state = next_state;
|
|
}
|
|
|
|
void Charger::discharge_control(BatConf *bat_conf)
|
|
{
|
|
#if BOARD_HAS_LOAD_OUTPUT || \
|
|
BOARD_HAS_USB_OUTPUT
|
|
|
|
if (!empty) {
|
|
// as we don't have a proper SOC estimation, we determine an empty battery by the main
|
|
// load output being switched off
|
|
if (flags_check(&load.error_flags, ERR_LOAD_SHEDDING)) {
|
|
empty = true;
|
|
num_deep_discharges++;
|
|
|
|
if (usable_capacity == 0.0F) {
|
|
// reset to measured value if discharged the first time
|
|
usable_capacity = discharged_Ah;
|
|
}
|
|
else {
|
|
// slowly adapt new measurements with low-pass filter
|
|
usable_capacity =
|
|
0.8F * usable_capacity +
|
|
0.2F * discharged_Ah;
|
|
}
|
|
|
|
// simple SOH estimation
|
|
soh = usable_capacity / bat_conf->nominal_capacity;
|
|
}
|
|
}
|
|
else {
|
|
if (!flags_check(&load.error_flags, ERR_LOAD_SHEDDING)) {
|
|
empty = false;
|
|
}
|
|
}
|
|
|
|
// negative current limit = allowed battery discharge current
|
|
if (port->neg_current_limit < 0) {
|
|
|
|
// This limit should normally never be reached, as the load output settings should be
|
|
// higher. The flag can be used to trigger actions of last resort, e.g. deep-sleep
|
|
// of the charge controller itself.
|
|
if (port->bus->voltage < port->bus->src_control_voltage(bat_conf->absolute_min_voltage)) {
|
|
port->neg_current_limit = 0;
|
|
dev_stat.set_error(ERR_BAT_UNDERVOLTAGE);
|
|
}
|
|
|
|
if (bat_temperature > bat_conf->discharge_temp_max) {
|
|
port->neg_current_limit = 0;
|
|
dev_stat.set_error(ERR_BAT_DIS_OVERTEMP);
|
|
}
|
|
else if (bat_temperature < bat_conf->discharge_temp_min) {
|
|
port->neg_current_limit = 0;
|
|
dev_stat.set_error(ERR_BAT_DIS_UNDERTEMP);
|
|
}
|
|
}
|
|
else {
|
|
// discharging currently not allowed. should we allow it?
|
|
|
|
if (port->bus->voltage >=
|
|
port->bus->src_control_voltage(bat_conf->absolute_min_voltage + 0.1F))
|
|
{
|
|
dev_stat.clear_error(ERR_BAT_UNDERVOLTAGE);
|
|
}
|
|
|
|
if (bat_temperature < bat_conf->discharge_temp_max - 1 &&
|
|
bat_temperature > bat_conf->discharge_temp_min + 1)
|
|
{
|
|
dev_stat.clear_error(ERR_BAT_DIS_OVERTEMP | ERR_BAT_DIS_UNDERTEMP);
|
|
}
|
|
|
|
if (!dev_stat.has_error(
|
|
ERR_BAT_UNDERVOLTAGE | ERR_BAT_DIS_OVERTEMP | ERR_BAT_DIS_UNDERTEMP))
|
|
{
|
|
// discharge current is stored as absolute value in bat_conf, but defined
|
|
// as negative current for power port
|
|
port->neg_current_limit = -bat_conf->discharge_current_max;
|
|
|
|
}
|
|
}
|
|
#endif
|
|
}
|
|
|
|
void Charger::charge_control(BatConf *bat_conf)
|
|
{
|
|
// check battery temperature for charging direction
|
|
if (bat_temperature > bat_conf->charge_temp_max) {
|
|
port->pos_current_limit = 0;
|
|
dev_stat.set_error(ERR_BAT_CHG_OVERTEMP);
|
|
enter_state(CHG_STATE_IDLE);
|
|
}
|
|
else if (bat_temperature < bat_conf->charge_temp_min) {
|
|
port->pos_current_limit = 0;
|
|
dev_stat.set_error(ERR_BAT_CHG_UNDERTEMP);
|
|
enter_state(CHG_STATE_IDLE);
|
|
}
|
|
|
|
if (dev_stat.has_error(ERR_BAT_OVERVOLTAGE) &&
|
|
port->bus->voltage < (bat_conf->absolute_max_voltage - 0.5F) *
|
|
port->bus->series_multiplier)
|
|
{
|
|
dev_stat.clear_error(ERR_BAT_OVERVOLTAGE);
|
|
}
|
|
|
|
if (state != CHG_STATE_FOLLOWER && (uptime() - time_last_ctrl_msg) <= 1) {
|
|
enter_state(CHG_STATE_FOLLOWER);
|
|
}
|
|
|
|
// state machine
|
|
switch (state) {
|
|
case CHG_STATE_IDLE: {
|
|
if ((time_state_changed == CHARGER_TIME_NEVER ||
|
|
((uptime() - time_state_changed) > bat_conf->time_limit_recharge &&
|
|
port->bus->voltage < port->bus->sink_control_voltage(
|
|
bat_conf->recharge_voltage))
|
|
)
|
|
&& port->bus->voltage > port->bus->sink_control_voltage(
|
|
bat_conf->absolute_min_voltage) // ToDo set error flag otherwise
|
|
&& bat_temperature < bat_conf->charge_temp_max - 1
|
|
&& bat_temperature > bat_conf->charge_temp_min + 1)
|
|
{
|
|
port->bus->sink_voltage_intercept = bat_conf->topping_voltage +
|
|
bat_conf->temperature_compensation * (bat_temperature - 25);
|
|
port->pos_current_limit = bat_conf->charge_current_max;
|
|
target_current_control = port->pos_current_limit;
|
|
full = false;
|
|
dev_stat.clear_error(ERR_BAT_CHG_OVERTEMP);
|
|
dev_stat.clear_error(ERR_BAT_CHG_UNDERTEMP);
|
|
dev_stat.clear_error(ERR_BAT_OVERVOLTAGE);
|
|
enter_state(CHG_STATE_BULK);
|
|
}
|
|
break;
|
|
}
|
|
case CHG_STATE_BULK: {
|
|
// continuously adjust voltage setting for temperature compensation
|
|
port->bus->sink_voltage_intercept = bat_conf->topping_voltage +
|
|
bat_conf->temperature_compensation * (bat_temperature - 25);
|
|
|
|
if (port->bus->voltage > port->bus->sink_control_voltage()) {
|
|
target_voltage_timer = 0;
|
|
enter_state(CHG_STATE_TOPPING);
|
|
}
|
|
break;
|
|
}
|
|
case CHG_STATE_TOPPING: {
|
|
// continuously adjust voltage setting for temperature compensation
|
|
port->bus->sink_voltage_intercept = bat_conf->topping_voltage +
|
|
bat_conf->temperature_compensation * (bat_temperature - 25);
|
|
|
|
// power sharing: multiple devices in parallel supply the same current
|
|
target_current_control = port->current_filtered;
|
|
|
|
if (port->bus->voltage_filtered >= port->bus->sink_control_voltage() - 0.05F) {
|
|
// battery is full if topping target voltage is still reached (i.e. sufficient
|
|
// solar power available) and time limit or cut-off current reached
|
|
if (port->current_filtered < bat_conf->topping_cutoff_current ||
|
|
target_voltage_timer > bat_conf->topping_duration)
|
|
{
|
|
full = true;
|
|
}
|
|
target_voltage_timer++;
|
|
}
|
|
else if (uptime() - time_state_changed > 8 * 60 * 60) {
|
|
// in topping phase already for 8 hours (i.e. not enough solar power available)
|
|
// --> go back to bulk charging for the next day
|
|
enter_state(CHG_STATE_BULK);
|
|
}
|
|
|
|
if (full) {
|
|
num_full_charges++;
|
|
discharged_Ah = 0; // reset coulomb counter
|
|
|
|
if (bat_conf->equalization_enabled && (
|
|
(uptime() - time_last_equalization) / (24*60*60)
|
|
>= bat_conf->equalization_trigger_days ||
|
|
num_deep_discharges - deep_dis_last_equalization
|
|
>= bat_conf->equalization_trigger_deep_cycles))
|
|
{
|
|
port->bus->sink_voltage_intercept = bat_conf->equalization_voltage;
|
|
port->pos_current_limit = bat_conf->equalization_current_limit;
|
|
enter_state(CHG_STATE_EQUALIZATION);
|
|
}
|
|
else if (bat_conf->float_enabled) {
|
|
port->bus->sink_voltage_intercept = bat_conf->float_voltage +
|
|
bat_conf->temperature_compensation * (bat_temperature - 25);
|
|
enter_state(CHG_STATE_FLOAT);
|
|
}
|
|
else {
|
|
port->pos_current_limit = 0;
|
|
enter_state(CHG_STATE_IDLE);
|
|
}
|
|
}
|
|
break;
|
|
}
|
|
case CHG_STATE_FLOAT: {
|
|
// continuously adjust voltage setting for temperature compensation
|
|
port->bus->sink_voltage_intercept = bat_conf->float_voltage +
|
|
bat_conf->temperature_compensation * (bat_temperature - 25);
|
|
|
|
target_current_control = port->current_filtered;
|
|
|
|
if (port->bus->voltage >= port->bus->sink_control_voltage()) {
|
|
time_target_voltage_reached = uptime();
|
|
}
|
|
|
|
if ((uptime() - time_target_voltage_reached > bat_conf->float_recharge_time) &&
|
|
port->bus->voltage_filtered < port->bus->sink_control_voltage(
|
|
bat_conf->recharge_voltage))
|
|
{
|
|
// the battery was discharged: float voltage could not be reached anymore
|
|
port->pos_current_limit = bat_conf->charge_current_max;
|
|
full = false;
|
|
// assumption: float does not harm the battery --> never go back to idle
|
|
// (for Li-ion battery: disable float!)
|
|
enter_state(CHG_STATE_BULK);
|
|
}
|
|
break;
|
|
}
|
|
case CHG_STATE_EQUALIZATION: {
|
|
// continuously adjust voltage setting for temperature compensation
|
|
port->bus->sink_voltage_intercept = bat_conf->equalization_voltage +
|
|
bat_conf->temperature_compensation * (bat_temperature - 25);
|
|
|
|
target_current_control = port->current_filtered;
|
|
|
|
// current or time limit for equalization reached
|
|
if (uptime() - time_state_changed > bat_conf->equalization_duration)
|
|
{
|
|
// reset triggers
|
|
time_last_equalization = uptime();
|
|
deep_dis_last_equalization = num_deep_discharges;
|
|
|
|
discharged_Ah = 0; // reset coulomb counter again
|
|
|
|
if (bat_conf->float_enabled) {
|
|
port->bus->sink_voltage_intercept = bat_conf->float_voltage +
|
|
bat_conf->temperature_compensation * (bat_temperature - 25);
|
|
enter_state(CHG_STATE_FLOAT);
|
|
}
|
|
else {
|
|
port->pos_current_limit = 0;
|
|
enter_state(CHG_STATE_IDLE);
|
|
}
|
|
}
|
|
break;
|
|
}
|
|
case CHG_STATE_FOLLOWER: {
|
|
if ((uptime() - time_last_ctrl_msg) > 1) {
|
|
// go back to normal state machine
|
|
port->pos_current_limit = bat_conf->charge_current_max;
|
|
enter_state(CHG_STATE_BULK);
|
|
}
|
|
else {
|
|
// set current target as received from external device
|
|
port->pos_current_limit = target_current_control;
|
|
// set safety limit for voltage
|
|
port->bus->sink_voltage_intercept = bat_conf->absolute_max_voltage;
|
|
}
|
|
break;
|
|
}
|
|
}
|
|
}
|
|
|
|
void Charger::init_terminal(BatConf *bat) const
|
|
{
|
|
port->bus->sink_voltage_intercept = bat->topping_voltage;
|
|
port->bus->src_voltage_intercept = bat->load_disconnect_voltage;
|
|
|
|
port->neg_current_limit = -bat->discharge_current_max;
|
|
port->pos_current_limit = bat->charge_current_max;
|
|
|
|
/*
|
|
* Negative sign for compensation of actual resistance
|
|
*
|
|
* droop_res is multiplied with number of series connected batteries to calculate control
|
|
* voltage, so we need to divide by number of batteries here for correction
|
|
*/
|
|
port->bus->sink_droop_res = -bat->wire_resistance /
|
|
static_cast<float>(port->bus->series_multiplier);
|
|
|
|
/*
|
|
* In discharging direction also include battery internal resistance for current-compensation
|
|
* of voltage setpoints
|
|
*/
|
|
port->bus->src_droop_res = -bat->wire_resistance /
|
|
static_cast<float>(port->bus->series_multiplier)
|
|
- bat->internal_resistance;
|
|
}
|