Files
charge-controller-firmware/app/src/bat_charger.cpp
T
Martin Jäger 8ab8ea244a Move to standard Zephyr T2 workspace structure (star topology)
https://docs.zephyrproject.org/latest/guides/west/workspaces.html

Previously, west manifest and CMake entry point were in zephyr subfolder
as required for PlatformIO. As PlatformIO support was dropped, we can
follow the default Zephyr folder structure more closely.

The application is built and flashed from app subfolder, where as unit
tests are run from tests subfolder.
2021-12-12 14:09:05 +01:00

644 lines
27 KiB
C++

/*
* Copyright (c) The Libre Solar Project Contributors
*
* SPDX-License-Identifier: Apache-2.0
*/
#include "bat_charger.h"
#include <zephyr.h>
#include <logging/log.h>
LOG_MODULE_REGISTER(bat_charger, CONFIG_BAT_LOG_LEVEL);
#include <math.h> // for fabs function
#include <stdio.h>
#include "board.h"
#include "helper.h"
#include "device_status.h"
extern DeviceStatus dev_stat;
extern LoadOutput load;
// DISCHARGE_CURRENT_MAX used to estimate current-compensation of load disconnect voltage
#if BOARD_HAS_LOAD_OUTPUT
#define DISCHARGE_CURRENT_MAX DT_PROP(DT_CHILD(DT_PATH(outputs), load), current_max)
#else
#define DISCHARGE_CURRENT_MAX DT_PROP(DT_PATH(pcb), dcdc_current_max)
#endif
void battery_conf_init(BatConf *bat, int type, int num_cells, float nominal_capacity)
{
bat->nominal_capacity = nominal_capacity;
// 1C should be safe for all batteries
bat->charge_current_max = bat->nominal_capacity;
bat->discharge_current_max = bat->nominal_capacity;
bat->time_limit_recharge = 60; // sec
bat->topping_duration = 120*60; // sec
bat->charge_temp_max = 50;
bat->charge_temp_min = -10;
bat->discharge_temp_max = 50;
bat->discharge_temp_min = -10;
switch (type)
{
case BAT_TYPE_FLOODED:
case BAT_TYPE_AGM:
case BAT_TYPE_GEL:
bat->absolute_max_voltage = static_cast<float>(num_cells) * 2.45F;
bat->topping_voltage = static_cast<float>(num_cells) * 2.4F;
bat->recharge_voltage = static_cast<float>(num_cells) * 2.2F;
// Cell-level thresholds based on EN 62509:2011 (both thresholds current-compensated)
bat->load_disconnect_voltage = static_cast<float>(num_cells) * 1.95F;
bat->load_reconnect_voltage = static_cast<float>(num_cells) * 2.10F;
// assumption: Battery selection matching charge controller
bat->internal_resistance = static_cast<float>(num_cells) * (1.95F - 1.80F) /
DISCHARGE_CURRENT_MAX;
bat->absolute_min_voltage = static_cast<float>(num_cells) * 1.6F;
// Voltages during idle (no charging/discharging current)
bat->ocv_full = static_cast<float>(num_cells) *
((type == BAT_TYPE_FLOODED) ? 2.10F : 2.15F);
bat->ocv_empty = static_cast<float>(num_cells) * 1.90F;
// https://batteryuniversity.com/learn/article/charging_the_lead_acid_battery
bat->topping_cutoff_current = bat->nominal_capacity * 0.04F; // 3-5 % of C/1
bat->float_enabled = true;
bat->float_recharge_time = 30*60;
// Values as suggested in EN 62509:2011
bat->float_voltage = static_cast<float>(num_cells) *
((type == BAT_TYPE_FLOODED) ? 2.35F : 2.3F);
// Enable for flooded batteries only, according to
// https://discoverbattery.com/battery-101/equalizing-flooded-batteries-only
bat->equalization_enabled = false;
// Values as suggested in EN 62509:2011
bat->equalization_voltage = static_cast<float>(num_cells) *
((type == BAT_TYPE_FLOODED) ? 2.50F : 2.45F);
bat->equalization_duration = 60*60;
bat->equalization_current_limit = (1.0F / 7.0F) * bat->nominal_capacity;
bat->equalization_trigger_days = 60;
bat->equalization_trigger_deep_cycles = 10;
bat->temperature_compensation = -0.003F; // -3 mV/°C/cell
break;
case BAT_TYPE_LFP:
bat->absolute_max_voltage = static_cast<float>(num_cells) * 3.60F;
bat->topping_voltage = static_cast<float>(num_cells) * 3.55F; // CV voltage
bat->recharge_voltage = static_cast<float>(num_cells) * 3.35F;
bat->load_disconnect_voltage = static_cast<float>(num_cells) * 3.00F;
bat->load_reconnect_voltage = static_cast<float>(num_cells) * 3.15F;
// 5% voltage drop at max current
bat->internal_resistance = bat->load_disconnect_voltage * 0.05F /
DISCHARGE_CURRENT_MAX;
bat->absolute_min_voltage = static_cast<float>(num_cells) * 2.0F;
// will give really nonlinear SOC calculation because of flat OCV of LFP cells...
bat->ocv_full = static_cast<float>(num_cells) * 3.4F;
bat->ocv_empty = static_cast<float>(num_cells) * 3.0F;
// C/10 cut-off at end of CV phase by default
bat->topping_cutoff_current = bat->nominal_capacity / 10;
bat->float_enabled = false;
bat->equalization_enabled = false;
bat->temperature_compensation = 0;
bat->charge_temp_min = 0;
break;
case BAT_TYPE_NMC:
case BAT_TYPE_NMC_HV:
bat->topping_voltage = static_cast<float>(num_cells) *
((type == BAT_TYPE_NMC_HV) ? 4.35F : 4.20F);
bat->absolute_max_voltage = bat->topping_voltage +
static_cast<float>(num_cells) * 0.05F;
bat->recharge_voltage = static_cast<float>(num_cells) * 3.9F;
bat->load_disconnect_voltage = static_cast<float>(num_cells) * 3.3F;
bat->load_reconnect_voltage = static_cast<float>(num_cells) * 3.6F;
// 5% voltage drop at max current
bat->internal_resistance = bat->load_disconnect_voltage * 0.05F /
DISCHARGE_CURRENT_MAX;
bat->absolute_min_voltage = static_cast<float>(num_cells) * 2.5F;
bat->ocv_full = static_cast<float>(num_cells) * 4.0F;
bat->ocv_empty = static_cast<float>(num_cells) * 3.0F;
// C/10 cut-off at end of CV phase by default
bat->topping_cutoff_current = bat->nominal_capacity / 10;
bat->float_enabled = false;
bat->equalization_enabled = false;
bat->temperature_compensation = 0;
bat->charge_temp_min = 0;
break;
case BAT_TYPE_CUSTOM:
#ifdef CONFIG_BAT_TYPE_CUSTOM
bat->absolute_max_voltage = 0.001F *
static_cast<float>(CONFIG_BAT_NUM_CELLS * CONFIG_CELL_ABS_MAX_VOLTAGE_MV);
bat->topping_voltage = 0.001F *
static_cast<float>(CONFIG_BAT_NUM_CELLS * CONFIG_CELL_TOPPING_VOLTAGE_MV);
bat->recharge_voltage = 0.001F *
static_cast<float>(CONFIG_BAT_NUM_CELLS * CONFIG_CELL_RECHARGE_VOLTAGE_MV);
bat->load_disconnect_voltage = 0.001F *
static_cast<float>(CONFIG_BAT_NUM_CELLS * CONFIG_CELL_DISCONNECT_VOLTAGE_MV);
bat->load_reconnect_voltage = 0.001F *
static_cast<float>(CONFIG_BAT_NUM_CELLS * CONFIG_CELL_RECONNECT_VOLTAGE_MV);
bat->internal_resistance = 0.001F *
static_cast<float>(CONFIG_BAT_NUM_CELLS * CONFIG_CELL_INTERNAL_RESISTANCE_MOHM);
bat->absolute_min_voltage = 0.001F *
static_cast<float>(CONFIG_BAT_NUM_CELLS * CONFIG_CELL_ABS_MIN_VOLTAGE_MV);
// Voltages during idle (no charging/discharging current)
bat->ocv_full = 0.001F *
static_cast<float>(CONFIG_BAT_NUM_CELLS * CONFIG_CELL_OCV_FULL_MV);
bat->ocv_empty = 0.001F *
static_cast<float>(CONFIG_BAT_NUM_CELLS * CONFIG_CELL_OCV_EMPTY_MV);
// https://batteryuniversity.com/learn/article/charging_the_lead_acid_battery
bat->topping_cutoff_current = bat->nominal_capacity * 0.04F; // 3-5 % of C/1
bat->float_enabled = IS_ENABLED(CONFIG_CELL_FLOAT);
bat->float_recharge_time = CONFIG_CELL_FLOAT_RECHARGE_TIME;
bat->float_voltage = 0.001F *
static_cast<float>(CONFIG_BAT_NUM_CELLS * CONFIG_CELL_FLOAT_VOLTAGE_MV);
bat->equalization_enabled = IS_ENABLED(CONFIG_CELL_EQUALIZATION);
bat->equalization_voltage = 0.001F *
static_cast<float>(CONFIG_BAT_NUM_CELLS * CONFIG_CELL_EQUALIZATION_VOLTAGE_MV);
bat->equalization_duration = CONFIG_CELL_EQUALIZATION_DURATION;
bat->equalization_current_limit = (1.0F / 7.0F) * bat->nominal_capacity;
bat->equalization_trigger_days = CONFIG_CELL_EQUALIZATION_TRIGGER_DAYS;
bat->equalization_trigger_deep_cycles = CONFIG_CELL_EQUALIZATION_TRIGGER_DEEP_CYCLES;
bat->temperature_compensation = 0.001F *
static_cast<float>(CONFIG_BAT_NUM_CELLS * CONFIG_CELL_TEMP_COMPENSATION_MV_K);
bat->charge_temp_max = CONFIG_BAT_CHARGE_TEMP_MAX;
bat->charge_temp_min = CONFIG_BAT_CHARGE_TEMP_MIN;
bat->discharge_temp_max = CONFIG_BAT_DISCHARGE_TEMP_MAX;
bat->discharge_temp_min = CONFIG_BAT_DISCHARGE_TEMP_MIN;
#else
LOG_ERR("Custom battery type cannot be initialized at runtime.");
#endif
break;
}
}
// checks settings in bat_conf for plausibility
bool battery_conf_check(BatConf *bat_conf)
{
// things to check:
// - load_disconnect/reconnect hysteresis makes sense?
// - cutoff current not extremely low/high
// - capacity plausible
LOG_DBG("battery_conf_check: %d %d %d %d %d %d %d",
bat_conf->load_reconnect_voltage > (bat_conf->load_disconnect_voltage + 0.6),
bat_conf->recharge_voltage < (bat_conf->topping_voltage - 0.4),
bat_conf->recharge_voltage > (bat_conf->load_disconnect_voltage + 1),
bat_conf->load_disconnect_voltage > (bat_conf->absolute_min_voltage + 0.4),
bat_conf->topping_cutoff_current < (bat_conf->nominal_capacity / 10.0),
bat_conf->topping_cutoff_current > 0.01,
(bat_conf->float_enabled == false ||
(bat_conf->float_voltage < bat_conf->topping_voltage &&
bat_conf->float_voltage > bat_conf->load_disconnect_voltage))
);
return (
bat_conf->load_reconnect_voltage > (bat_conf->load_disconnect_voltage + 0.4) &&
bat_conf->recharge_voltage < (bat_conf->topping_voltage - 0.4) &&
bat_conf->recharge_voltage > (bat_conf->load_disconnect_voltage + 1) &&
bat_conf->load_disconnect_voltage > (bat_conf->absolute_min_voltage + 0.4) &&
// max. 10% drop
bat_conf->internal_resistance < bat_conf->load_disconnect_voltage * 0.1 /
DISCHARGE_CURRENT_MAX &&
// max. 3% loss
bat_conf->wire_resistance < bat_conf->topping_voltage * 0.03 / DISCHARGE_CURRENT_MAX &&
// C/10 or lower current cutoff allowed
bat_conf->topping_cutoff_current < (bat_conf->nominal_capacity / 10.0) &&
bat_conf->topping_cutoff_current > 0.01 &&
(bat_conf->float_enabled == false ||
(bat_conf->float_voltage < bat_conf->topping_voltage &&
bat_conf->float_voltage > bat_conf->load_disconnect_voltage))
);
}
void battery_conf_overwrite(BatConf *source, BatConf *destination, Charger *charger)
{
// TODO: stop DC/DC
destination->topping_voltage = source->topping_voltage;
destination->recharge_voltage = source->recharge_voltage;
destination->load_reconnect_voltage = source->load_reconnect_voltage;
destination->load_disconnect_voltage = source->load_disconnect_voltage;
destination->absolute_max_voltage = source->absolute_max_voltage;
destination->absolute_min_voltage = source->absolute_min_voltage;
destination->charge_current_max = source->charge_current_max;
destination->topping_cutoff_current = source->topping_cutoff_current;
destination->topping_duration = source->topping_duration;
destination->float_enabled = source->float_enabled;
destination->float_voltage = source->float_voltage;
destination->float_recharge_time = source->float_recharge_time;
destination->charge_temp_max = source->charge_temp_max;
destination->charge_temp_min = source->charge_temp_min;
destination->discharge_temp_max = source->discharge_temp_max;
destination->discharge_temp_min = source->discharge_temp_min;
destination->temperature_compensation = source->temperature_compensation;
destination->internal_resistance = source->internal_resistance;
destination->wire_resistance = source->wire_resistance;
// reset Ah counter and SOH if battery nominal capacity was changed
if (destination->nominal_capacity != source->nominal_capacity) {
destination->nominal_capacity = source->nominal_capacity;
if (charger != NULL) {
charger->discharged_Ah = 0;
charger->usable_capacity = 0;
charger->soh = 0;
}
}
// TODO:
// - update also DC/DC etc. (now this function only works at system startup)
// - restart DC/DC
}
bool battery_conf_changed(BatConf *a, BatConf *b)
{
return (
a->topping_voltage != b->topping_voltage ||
a->recharge_voltage != b->recharge_voltage ||
a->load_reconnect_voltage != b->load_reconnect_voltage ||
a->load_disconnect_voltage != b->load_disconnect_voltage ||
a->absolute_max_voltage != b->absolute_max_voltage ||
a->absolute_min_voltage != b->absolute_min_voltage ||
a->charge_current_max != b->charge_current_max ||
a->topping_cutoff_current != b->topping_cutoff_current ||
a->topping_duration != b->topping_duration ||
a->float_enabled != b->float_enabled ||
a->float_voltage != b->float_voltage ||
a->float_recharge_time != b->float_recharge_time ||
a->charge_temp_max != b->charge_temp_max ||
a->charge_temp_min != b->charge_temp_min ||
a->discharge_temp_max != b->discharge_temp_max ||
a->discharge_temp_min != b->discharge_temp_min ||
a->temperature_compensation != b->temperature_compensation ||
a->internal_resistance != b->internal_resistance ||
a->wire_resistance != b->wire_resistance
);
}
void Charger::detect_num_batteries(BatConf *bat) const
{
if (port->bus->voltage > bat->absolute_min_voltage * 2 &&
port->bus->voltage < bat->absolute_max_voltage * 2)
{
port->bus->series_multiplier = 2;
printf("Detected two batteries (total %.2f V max)\n", bat->topping_voltage * 2);
}
else {
printf("Detected single battery (%.2f V max)\n", bat->topping_voltage);
}
}
void Charger::update_soc(BatConf *bat_conf)
{
static int soc_filtered = 0; // SOC / 100 for better filtering
if (fabs(port->current) < 0.2) {
int soc_new = (int)((port->bus->voltage - bat_conf->ocv_empty) /
(bat_conf->ocv_full - bat_conf->ocv_empty) * 10000.0);
if (soc_new > 500 && soc_filtered == 0) {
// bypass filter during initialization
soc_filtered = soc_new;
}
else {
// filtering to adjust SOC very slowly
soc_filtered += (soc_new - soc_filtered) / 100;
}
if (soc_filtered > 10000) {
soc_filtered = 10000;
}
else if (soc_filtered < 0) {
soc_filtered = 0;
}
soc = soc_filtered / 100;
}
discharged_Ah += -port->current / 3600.0F; // charged current is positive: change sign
}
void Charger::enter_state(int next_state)
{
LOG_DBG("Enter State: %d", next_state);
time_state_changed = uptime();
state = next_state;
}
void Charger::discharge_control(BatConf *bat_conf)
{
#if BOARD_HAS_LOAD_OUTPUT || \
BOARD_HAS_USB_OUTPUT
if (!empty) {
// as we don't have a proper SOC estimation, we determine an empty battery by the main
// load output being switched off
if (flags_check(&load.error_flags, ERR_LOAD_SHEDDING)) {
empty = true;
num_deep_discharges++;
if (usable_capacity == 0.0F) {
// reset to measured value if discharged the first time
usable_capacity = discharged_Ah;
}
else {
// slowly adapt new measurements with low-pass filter
usable_capacity =
0.8F * usable_capacity +
0.2F * discharged_Ah;
}
// simple SOH estimation
soh = usable_capacity / bat_conf->nominal_capacity;
}
}
else {
if (!flags_check(&load.error_flags, ERR_LOAD_SHEDDING)) {
empty = false;
}
}
// negative current limit = allowed battery discharge current
if (port->neg_current_limit < 0) {
// This limit should normally never be reached, as the load output settings should be
// higher. The flag can be used to trigger actions of last resort, e.g. deep-sleep
// of the charge controller itself.
if (port->bus->voltage < port->bus->src_control_voltage(bat_conf->absolute_min_voltage)) {
port->neg_current_limit = 0;
dev_stat.set_error(ERR_BAT_UNDERVOLTAGE);
}
if (bat_temperature > bat_conf->discharge_temp_max) {
port->neg_current_limit = 0;
dev_stat.set_error(ERR_BAT_DIS_OVERTEMP);
}
else if (bat_temperature < bat_conf->discharge_temp_min) {
port->neg_current_limit = 0;
dev_stat.set_error(ERR_BAT_DIS_UNDERTEMP);
}
}
else {
// discharging currently not allowed. should we allow it?
if (port->bus->voltage >=
port->bus->src_control_voltage(bat_conf->absolute_min_voltage + 0.1F))
{
dev_stat.clear_error(ERR_BAT_UNDERVOLTAGE);
}
if (bat_temperature < bat_conf->discharge_temp_max - 1 &&
bat_temperature > bat_conf->discharge_temp_min + 1)
{
dev_stat.clear_error(ERR_BAT_DIS_OVERTEMP | ERR_BAT_DIS_UNDERTEMP);
}
if (!dev_stat.has_error(
ERR_BAT_UNDERVOLTAGE | ERR_BAT_DIS_OVERTEMP | ERR_BAT_DIS_UNDERTEMP))
{
// discharge current is stored as absolute value in bat_conf, but defined
// as negative current for power port
port->neg_current_limit = -bat_conf->discharge_current_max;
}
}
#endif
}
void Charger::charge_control(BatConf *bat_conf)
{
// check battery temperature for charging direction
if (bat_temperature > bat_conf->charge_temp_max) {
port->pos_current_limit = 0;
dev_stat.set_error(ERR_BAT_CHG_OVERTEMP);
enter_state(CHG_STATE_IDLE);
}
else if (bat_temperature < bat_conf->charge_temp_min) {
port->pos_current_limit = 0;
dev_stat.set_error(ERR_BAT_CHG_UNDERTEMP);
enter_state(CHG_STATE_IDLE);
}
if (dev_stat.has_error(ERR_BAT_OVERVOLTAGE) &&
port->bus->voltage < (bat_conf->absolute_max_voltage - 0.5F) *
port->bus->series_multiplier)
{
dev_stat.clear_error(ERR_BAT_OVERVOLTAGE);
}
if (state != CHG_STATE_FOLLOWER && (uptime() - time_last_ctrl_msg) <= 1) {
enter_state(CHG_STATE_FOLLOWER);
}
// state machine
switch (state) {
case CHG_STATE_IDLE: {
if ((time_state_changed == CHARGER_TIME_NEVER ||
((uptime() - time_state_changed) > bat_conf->time_limit_recharge &&
port->bus->voltage < port->bus->sink_control_voltage(
bat_conf->recharge_voltage))
)
&& port->bus->voltage > port->bus->sink_control_voltage(
bat_conf->absolute_min_voltage) // ToDo set error flag otherwise
&& bat_temperature < bat_conf->charge_temp_max - 1
&& bat_temperature > bat_conf->charge_temp_min + 1)
{
port->bus->sink_voltage_intercept = bat_conf->topping_voltage +
bat_conf->temperature_compensation * (bat_temperature - 25);
port->pos_current_limit = bat_conf->charge_current_max;
target_current_control = port->pos_current_limit;
full = false;
dev_stat.clear_error(ERR_BAT_CHG_OVERTEMP);
dev_stat.clear_error(ERR_BAT_CHG_UNDERTEMP);
dev_stat.clear_error(ERR_BAT_OVERVOLTAGE);
enter_state(CHG_STATE_BULK);
}
break;
}
case CHG_STATE_BULK: {
// continuously adjust voltage setting for temperature compensation
port->bus->sink_voltage_intercept = bat_conf->topping_voltage +
bat_conf->temperature_compensation * (bat_temperature - 25);
if (port->bus->voltage > port->bus->sink_control_voltage()) {
target_voltage_timer = 0;
enter_state(CHG_STATE_TOPPING);
}
break;
}
case CHG_STATE_TOPPING: {
// continuously adjust voltage setting for temperature compensation
port->bus->sink_voltage_intercept = bat_conf->topping_voltage +
bat_conf->temperature_compensation * (bat_temperature - 25);
// power sharing: multiple devices in parallel supply the same current
target_current_control = port->current_filtered;
if (port->bus->voltage_filtered >= port->bus->sink_control_voltage() - 0.05F) {
// battery is full if topping target voltage is still reached (i.e. sufficient
// solar power available) and time limit or cut-off current reached
if (port->current_filtered < bat_conf->topping_cutoff_current ||
target_voltage_timer > bat_conf->topping_duration)
{
full = true;
}
target_voltage_timer++;
}
else if (uptime() - time_state_changed > 8 * 60 * 60) {
// in topping phase already for 8 hours (i.e. not enough solar power available)
// --> go back to bulk charging for the next day
enter_state(CHG_STATE_BULK);
}
if (full) {
num_full_charges++;
discharged_Ah = 0; // reset coulomb counter
if (bat_conf->equalization_enabled && (
(uptime() - time_last_equalization) / (24*60*60)
>= bat_conf->equalization_trigger_days ||
num_deep_discharges - deep_dis_last_equalization
>= bat_conf->equalization_trigger_deep_cycles))
{
port->bus->sink_voltage_intercept = bat_conf->equalization_voltage;
port->pos_current_limit = bat_conf->equalization_current_limit;
enter_state(CHG_STATE_EQUALIZATION);
}
else if (bat_conf->float_enabled) {
port->bus->sink_voltage_intercept = bat_conf->float_voltage +
bat_conf->temperature_compensation * (bat_temperature - 25);
enter_state(CHG_STATE_FLOAT);
}
else {
port->pos_current_limit = 0;
enter_state(CHG_STATE_IDLE);
}
}
break;
}
case CHG_STATE_FLOAT: {
// continuously adjust voltage setting for temperature compensation
port->bus->sink_voltage_intercept = bat_conf->float_voltage +
bat_conf->temperature_compensation * (bat_temperature - 25);
target_current_control = port->current_filtered;
if (port->bus->voltage >= port->bus->sink_control_voltage()) {
time_target_voltage_reached = uptime();
}
if ((uptime() - time_target_voltage_reached > bat_conf->float_recharge_time) &&
port->bus->voltage_filtered < port->bus->sink_control_voltage(
bat_conf->recharge_voltage))
{
// the battery was discharged: float voltage could not be reached anymore
port->pos_current_limit = bat_conf->charge_current_max;
full = false;
// assumption: float does not harm the battery --> never go back to idle
// (for Li-ion battery: disable float!)
enter_state(CHG_STATE_BULK);
}
break;
}
case CHG_STATE_EQUALIZATION: {
// continuously adjust voltage setting for temperature compensation
port->bus->sink_voltage_intercept = bat_conf->equalization_voltage +
bat_conf->temperature_compensation * (bat_temperature - 25);
target_current_control = port->current_filtered;
// current or time limit for equalization reached
if (uptime() - time_state_changed > bat_conf->equalization_duration)
{
// reset triggers
time_last_equalization = uptime();
deep_dis_last_equalization = num_deep_discharges;
discharged_Ah = 0; // reset coulomb counter again
if (bat_conf->float_enabled) {
port->bus->sink_voltage_intercept = bat_conf->float_voltage +
bat_conf->temperature_compensation * (bat_temperature - 25);
enter_state(CHG_STATE_FLOAT);
}
else {
port->pos_current_limit = 0;
enter_state(CHG_STATE_IDLE);
}
}
break;
}
case CHG_STATE_FOLLOWER: {
if ((uptime() - time_last_ctrl_msg) > 1) {
// go back to normal state machine
port->pos_current_limit = bat_conf->charge_current_max;
enter_state(CHG_STATE_BULK);
}
else {
// set current target as received from external device
port->pos_current_limit = target_current_control;
// set safety limit for voltage
port->bus->sink_voltage_intercept = bat_conf->absolute_max_voltage;
}
break;
}
}
}
void Charger::init_terminal(BatConf *bat) const
{
port->bus->sink_voltage_intercept = bat->topping_voltage;
port->bus->src_voltage_intercept = bat->load_disconnect_voltage;
port->neg_current_limit = -bat->discharge_current_max;
port->pos_current_limit = bat->charge_current_max;
/*
* Negative sign for compensation of actual resistance
*
* droop_res is multiplied with number of series connected batteries to calculate control
* voltage, so we need to divide by number of batteries here for correction
*/
port->bus->sink_droop_res = -bat->wire_resistance /
static_cast<float>(port->bus->series_multiplier);
/*
* In discharging direction also include battery internal resistance for current-compensation
* of voltage setpoints
*/
port->bus->src_droop_res = -bat->wire_resistance /
static_cast<float>(port->bus->series_multiplier)
- bat->internal_resistance;
}