- DcBus representing actual screw terminals renamed - Internal DC bus at DC/DC low voltage side added for correct DC/DC control - DC/DC struct now stores pointers to HV and LV bus objects. Redundant voltage and current measurement variables removed. - Unit tests updated DC/DC control needs further improvements to make use of the changes
166 lines
5.3 KiB
C++
166 lines
5.3 KiB
C++
|
|
#include "tests.h"
|
|
|
|
#include "bat_charger.h"
|
|
#include "dc_bus.h"
|
|
|
|
#include <time.h>
|
|
#include <stdio.h>
|
|
|
|
extern BatConf bat_conf;
|
|
extern Charger charger;
|
|
extern DcBus *bat_terminal;
|
|
|
|
static void init_structs()
|
|
{
|
|
battery_conf_init(&bat_conf, BAT_TYPE_FLOODED, 6, 100);
|
|
charger_init(&charger);
|
|
battery_init_dc_bus(bat_terminal, &bat_conf, 1);
|
|
charger.state = CHG_STATE_IDLE;
|
|
}
|
|
|
|
void no_start_at_high_voltage()
|
|
{
|
|
init_structs();
|
|
bat_terminal->voltage = bat_conf.voltage_recharge + 0.1;
|
|
charger_state_machine(bat_terminal, &bat_conf, &charger);
|
|
TEST_ASSERT_EQUAL(CHG_STATE_IDLE, charger.state);
|
|
}
|
|
|
|
void no_start_after_short_rest()
|
|
{
|
|
init_structs();
|
|
charger.time_state_changed = time(NULL) - bat_conf.time_limit_recharge + 1;
|
|
bat_terminal->voltage = bat_conf.voltage_recharge - 0.1;
|
|
charger_state_machine(bat_terminal, &bat_conf, &charger);
|
|
TEST_ASSERT_EQUAL(CHG_STATE_IDLE, charger.state);
|
|
}
|
|
|
|
void no_start_outside_temperature_limits()
|
|
{
|
|
init_structs();
|
|
charger.bat_temperature = bat_conf.charge_temp_max + 1;
|
|
bat_terminal->voltage = bat_conf.voltage_recharge - 0.1;
|
|
charger_state_machine(bat_terminal, &bat_conf, &charger);
|
|
TEST_ASSERT_EQUAL(CHG_STATE_IDLE, charger.state);
|
|
|
|
charger.bat_temperature = bat_conf.charge_temp_min - 1;
|
|
charger_state_machine(bat_terminal, &bat_conf, &charger);
|
|
TEST_ASSERT_EQUAL(CHG_STATE_IDLE, charger.state);
|
|
}
|
|
|
|
void start_if_everything_just_fine()
|
|
{
|
|
init_structs();
|
|
charger.time_state_changed = time(NULL) - bat_conf.time_limit_recharge - 1;
|
|
bat_terminal->voltage = bat_conf.voltage_recharge - 0.1;
|
|
charger_state_machine(bat_terminal, &bat_conf, &charger);
|
|
TEST_ASSERT_EQUAL(CHG_STATE_BULK, charger.state);
|
|
}
|
|
|
|
void enter_topping_at_voltage_setpoint()
|
|
{
|
|
init_structs();
|
|
charger.time_state_changed = time(NULL) - bat_conf.time_limit_recharge - 1;
|
|
bat_terminal->voltage = bat_conf.voltage_recharge - 0.1;
|
|
charger_state_machine(bat_terminal, &bat_conf, &charger);
|
|
TEST_ASSERT_EQUAL(CHG_STATE_BULK, charger.state);
|
|
bat_terminal->voltage = bat_conf.voltage_topping + 0.1;
|
|
charger_state_machine(bat_terminal, &bat_conf, &charger);
|
|
TEST_ASSERT_EQUAL(CHG_STATE_TOPPING, charger.state);
|
|
}
|
|
|
|
void stop_topping_after_time_limit()
|
|
{
|
|
enter_topping_at_voltage_setpoint();
|
|
|
|
charger.time_state_changed = time(NULL) - bat_conf.time_limit_topping + 1;
|
|
bat_terminal->voltage = bat_conf.voltage_topping + 0.1;
|
|
bat_terminal->current = bat_conf.current_cutoff_topping + 0.1;
|
|
|
|
charger_state_machine(bat_terminal, &bat_conf, &charger);
|
|
TEST_ASSERT_EQUAL(CHG_STATE_TOPPING, charger.state);
|
|
|
|
charger.time_state_changed = time(NULL) - bat_conf.time_limit_topping - 1;
|
|
charger_state_machine(bat_terminal, &bat_conf, &charger);
|
|
TEST_ASSERT_EQUAL(CHG_STATE_TRICKLE, charger.state);
|
|
}
|
|
|
|
void stop_topping_at_cutoff_current()
|
|
{
|
|
enter_topping_at_voltage_setpoint();
|
|
|
|
charger.time_state_changed = time(NULL) - 1;
|
|
bat_terminal->voltage = bat_conf.voltage_topping + 0.1;
|
|
bat_terminal->current = bat_conf.current_cutoff_topping - 0.1;
|
|
charger_state_machine(bat_terminal, &bat_conf, &charger);
|
|
TEST_ASSERT_EQUAL(CHG_STATE_TRICKLE, charger.state);
|
|
}
|
|
|
|
void trickle_to_idle_for_li_ion()
|
|
{
|
|
enter_topping_at_voltage_setpoint();
|
|
battery_conf_init(&bat_conf, BAT_TYPE_LFP, 4, 100);
|
|
|
|
charger.time_state_changed = time(NULL) - 1;
|
|
bat_terminal->voltage = bat_conf.voltage_topping + 0.1;
|
|
bat_terminal->current = bat_conf.current_cutoff_topping - 0.1;
|
|
charger_state_machine(bat_terminal, &bat_conf, &charger);
|
|
TEST_ASSERT_EQUAL(CHG_STATE_IDLE, charger.state);
|
|
}
|
|
|
|
void trickle_to_equalization_if_enabled()
|
|
{
|
|
enter_topping_at_voltage_setpoint();
|
|
bat_conf.equalization_enabled = true;
|
|
|
|
charger.time_state_changed = time(NULL) - 1;
|
|
bat_terminal->voltage = bat_conf.voltage_topping + 0.1;
|
|
bat_terminal->current = bat_conf.current_cutoff_topping - 0.1;
|
|
charger_state_machine(bat_terminal, &bat_conf, &charger);
|
|
TEST_ASSERT_EQUAL(CHG_STATE_EQUALIZATION, charger.state);
|
|
}
|
|
|
|
void no_trickle_if_low_current_because_of_low_input()
|
|
{
|
|
enter_topping_at_voltage_setpoint();
|
|
|
|
charger.time_state_changed = time(NULL) - 200;
|
|
charger.time_voltage_limit_reached = time(NULL) - 3;
|
|
bat_terminal->voltage = bat_conf.voltage_topping - 0.1;
|
|
bat_terminal->current = bat_conf.current_cutoff_topping - 0.1;
|
|
|
|
charger_state_machine(bat_terminal, &bat_conf, &charger);
|
|
TEST_ASSERT_EQUAL(CHG_STATE_TOPPING, charger.state);
|
|
|
|
charger.time_voltage_limit_reached = time(NULL) - 1;
|
|
charger_state_machine(bat_terminal, &bat_conf, &charger);
|
|
TEST_ASSERT_EQUAL(CHG_STATE_TRICKLE, charger.state);
|
|
}
|
|
|
|
void restart_bulk_from_trickle_if_voltage_drops()
|
|
{
|
|
TEST_ASSERT(0);
|
|
}
|
|
|
|
void bat_charger_tests()
|
|
{
|
|
UNITY_BEGIN();
|
|
|
|
RUN_TEST(no_start_at_high_voltage);
|
|
RUN_TEST(no_start_after_short_rest);
|
|
RUN_TEST(no_start_outside_temperature_limits);
|
|
RUN_TEST(start_if_everything_just_fine);
|
|
RUN_TEST(enter_topping_at_voltage_setpoint);
|
|
RUN_TEST(stop_topping_after_time_limit);
|
|
RUN_TEST(stop_topping_at_cutoff_current);
|
|
RUN_TEST(trickle_to_idle_for_li_ion);
|
|
//RUN_TEST(trickle_to_equalization_if_enabled);
|
|
RUN_TEST(no_trickle_if_low_current_because_of_low_input);
|
|
//RUN_TEST(restart_bulk_from_trickle_if_voltage_drops);
|
|
|
|
// TODO: temperature compensation
|
|
// TODO: current compensation
|
|
|
|
UNITY_END();
|
|
} |