Overcurrent protection in PWM charge controller not yet working for Zephyr.
119 lines
3.8 KiB
C++
119 lines
3.8 KiB
C++
/*
|
|
* Copyright (c) 2016 Martin Jäger / Libre Solar
|
|
*
|
|
* SPDX-License-Identifier: Apache-2.0
|
|
*/
|
|
|
|
#ifndef LOAD_H
|
|
#define LOAD_H
|
|
|
|
/** @file
|
|
*
|
|
* @brief
|
|
* Load/USB output functions and data types
|
|
*/
|
|
|
|
#include <stdint.h>
|
|
#include <stdbool.h>
|
|
#include <time.h>
|
|
|
|
#include "power_port.h"
|
|
|
|
/** Load/USB output states
|
|
*
|
|
* Used for USB or normal load outputs connecting to battery via switch.
|
|
*
|
|
* DEPRECATED: These states will be removed in the future and the status will be determined only
|
|
* by the error flags.
|
|
*/
|
|
enum LoadState {
|
|
LOAD_STATE_DISABLED = 0, ///< Actively disabled
|
|
LOAD_STATE_ON, ///< Normal state: On
|
|
LOAD_STATE_OFF_LOW_SOC, ///< Off to protect battery (overrules target setting)
|
|
LOAD_STATE_OFF_OVERCURRENT, ///< Off to protect charge controller (overrules target setting)
|
|
LOAD_STATE_OFF_OVERVOLTAGE, ///< Off to protect loads (overrules target setting)
|
|
LOAD_STATE_OFF_SHORT_CIRCUIT, ///< Off to protect charge controller (overrules target setting)
|
|
LOAD_STATE_OFF_TEMPERATURE ///< Off because of battery or charge controller temperature
|
|
};
|
|
|
|
/** Load output type
|
|
*
|
|
* Stores status of load output incl. 5V USB output (if existing on PCB)
|
|
*/
|
|
class LoadOutput
|
|
{
|
|
public:
|
|
/** Initialize LoadOutput struct and overcurrent / short circuit protection comparator (if existing)
|
|
*
|
|
* @param load Load output struct
|
|
* @param bus_int Internal DC bus the load switch is connected to (e.g. battery and DC/DC junction)
|
|
* @param terminal Load terminal DC bus (external interface)
|
|
*/
|
|
LoadOutput(PowerPort *pwr_port);
|
|
|
|
/** Enable/disable load switch
|
|
*/
|
|
void switch_set(bool enabled);
|
|
|
|
/** Enable/disable USB output
|
|
*/
|
|
void usb_set(bool enabled);
|
|
|
|
/** USB state machine, called every second.
|
|
*/
|
|
void usb_state_machine();
|
|
|
|
/** Main load control function, should be called by control timer
|
|
*
|
|
* This function includes the load state machine
|
|
*/
|
|
void control();
|
|
|
|
/** Fast emergency stop function
|
|
*
|
|
* May be called from an ISR which detected overvoltage / overcurrent conditions
|
|
*
|
|
* @param error_flag Optional error flag that should be set
|
|
*/
|
|
void stop(uint32_t error_flag = 0);
|
|
|
|
int state; ///< Current state of load output switch (DEPRECATED)
|
|
int usb_state; ///< Current state of USB output (DEPRECATED)
|
|
|
|
PowerPort *port; ///< Pointer to DC bus containting actual voltage and current
|
|
///< measurement of (external) load output terminal
|
|
|
|
bool enable; ///< Target on state set via communication port (overruled if
|
|
///< battery is empty or any errors occured)
|
|
bool usb_enable; ///< Target on state for USB output
|
|
|
|
bool pgood = false; ///< Power good flag that is true if load switch is on
|
|
bool usb_pgood = false; ///< Power good flag for USB output
|
|
|
|
time_t oc_timestamp; ///< Time when last overcurrent event occured
|
|
int oc_recovery_delay; ///< Seconds before we attempt to re-enable the load
|
|
///< after an overcurrent event
|
|
|
|
time_t lvd_timestamp; ///< Time when last low voltage disconnect happened
|
|
int lvd_recovery_delay; ///< Seconds before we re-enable the load after a low voltage
|
|
///< disconnect
|
|
|
|
float junction_temperature; ///< calculated using thermal model based on current and ambient
|
|
///< temperature measurement (unit: °C)
|
|
|
|
float ov_hysteresis; ///< Hysteresis to switch back on after an overvoltage event
|
|
|
|
private:
|
|
int determine_load_state();
|
|
void short_circuit_comp_init();
|
|
|
|
#ifdef __ZEPHYR__
|
|
void get_bindings();
|
|
|
|
struct device *dev_load;
|
|
struct device *dev_usb;
|
|
#endif
|
|
};
|
|
|
|
#endif /* LOAD_H */
|