Files
charge-controller-firmware/src/load.h
T
Martin Jäger e76709f2af Enable load short circuit comparator
The load driver had to be moved to a .c file to allow attaching interrupt
in Zephyr.
2020-05-06 12:53:26 +02:00

191 lines
5.4 KiB
C++

/*
* Copyright (c) 2016 Martin Jäger / Libre Solar
*
* SPDX-License-Identifier: Apache-2.0
*/
#ifndef LOAD_H
#define LOAD_H
/** @file
*
* @brief
* Load/USB output functions and data types
*/
#include <stdint.h>
#include <stdbool.h>
#include <time.h>
#ifdef __cplusplus
#include "power_port.h"
/**
* Load/USB output states
*/
enum LoadState {
LOAD_STATE_OFF = 0, ///< Actively disabled
LOAD_STATE_ON = 1, ///< Normal state: On
};
/** Load error flags
*
* When adding new flags, please make sure to use only up to 32 errors
* Each enum must represent a unique power of 2 number
*/
enum LoadErrorFlag {
/**
* Available energy or power too low
*
* Switching off the load can be triggered either by a low battery voltage or by low state of
* charge (SOC) in case of more advanced battery management.
*
* Set in LoadOutput::control() and cleared after reconnect delay passed and voltage is above
* reconnect threshold again.
*/
ERR_LOAD_SHEDDING = 1U << 0,
/**
* Too high voltage for load
*
* Set and cleared in LoadOutput::control()
*/
ERR_LOAD_OVERVOLTAGE = 1U << 1,
/**
* Long-term overcurrent at load port
*
* Set in LoadOutput::control() and cleared after configurable delay.
*/
ERR_LOAD_OVERCURRENT = 1U << 2,
/**
* Short circuit detected at load port
*
* Set by LoadOutput::control() after overcurrent comparator triggered, cleared only if
* load output is manually disabled and enabled again.
*/
ERR_LOAD_SHORT_CIRCUIT = 1U << 3,
/**
* Overcurrent identified via voltage dip (may be caused by too small battery)
*
* Set and cleared in LoadOutput::control(). Treated same as load overcurrent.
*/
ERR_LOAD_VOLTAGE_DIP = 1U << 4,
/**
* The bus the load is connected to disabled sourcing current from it
*
* Reasons can be that battery temperature limits were exceeded. Voltage limits should be
* covered by the load directly.
*/
ERR_LOAD_BUS_SRC_CURRENT = 1U << 5
};
/** Load output type
*
* Stores status of load output incl. 5V USB output (if existing on PCB)
*/
class LoadOutput : public PowerPort
{
public:
/**
* Initialize LoadOutput struct and overcurrent / short circuit protection comparator (if existing)
*
* @param dc_bus DC bus the load is connected to
* @param switch_set Pointer to function for enabling/disabling load switch
* @param init Pointer to function for load driver initialization
*/
LoadOutput(DcBus *dc_bus, void (*switch_fn)(bool), void (*init_fn)());
/** Main load control function, should be called by control timer
*
* This function includes the load state machine
*/
void control();
/** Fast emergency stop function
*
* May be called from an ISR which detected overvoltage / overcurrent conditions
*
* @param error_flag Optional error flag that should be set
*/
void stop(uint32_t error_flag = 0);
/**
* Update of load voltage limits (typically based on battery configuration)
*
* @param lvd Low voltage disconnect setpoint
* @param lvr Low voltage reconnect setpoint
* @param ov Overvoltage setpoint
*/
void set_voltage_limits(float lvd, float lvr, float ov);
uint32_t state; ///< Current state of load output switch
uint32_t error_flags = 0; ///< Stores error flags as bits according to LoadErrorFlag enum
int32_t info; ///< Contains either the state or negative value of error_flags
///< in case of error_flags > 0. This allows to have a single
///< variable for load state diagnosis.
bool enable = false; ///< Target on state set via communication port (overruled if
///< battery is empty or any errors occured)
time_t oc_timestamp; ///< Time when last overcurrent event occured
int32_t oc_recovery_delay; ///< Seconds before we attempt to re-enable the load
///< after an overcurrent event
float disconnect_voltage = 0; ///< Low voltage disconnect (LVD) setpoint
float reconnect_voltage = 0; ///< Low voltage reconnect (LVD) setpoint
time_t lvd_timestamp; ///< Time when last low voltage disconnect happened
int32_t lvd_recovery_delay; ///< Seconds before we re-enable the load after a low voltage
///< disconnect
float junction_temperature; ///< calculated using thermal model based on current and ambient
///< temperature measurement (unit: °C)
float overvoltage = 0; ///< Upper voltage limit
float ov_hysteresis; ///< Hysteresis to switch back on after an overvoltage event
private:
/**
* Pointer to the load switch function
*/
void (*switch_set)(bool);
/**
* Used to prevent switching of because of very short voltage dip
*/
int uv_debounce_counter = 0;
/**
* Used to prevent switching off because of short voltage spike
*/
int ov_debounce_counter = 0;
};
#endif
#ifdef __cplusplus
extern "C" {
#endif
void load_out_init();
void usb_out_init();
void load_out_set(bool);
void usb_out_set(bool);
void load_short_circuit_stop();
#ifdef __cplusplus
}
#endif
#endif /* LOAD_H */