The DC bus type caused issues because current limits could not be defined individually for each connection to a junction, as described in issue #50. With this commit, also some structs were converted to C++ classes to improve readibility of the code and make sure that pointers (e.g. to PowerPort objects) are always assigned during initialization.
70 lines
2.0 KiB
C++
70 lines
2.0 KiB
C++
|
|
#include "tests.h"
|
|
#include "adc_dma.h"
|
|
#include "adc_dma_stub.h"
|
|
|
|
#include "main.h"
|
|
|
|
static adc_values_t adcval;
|
|
|
|
void check_solar_terminal_readings()
|
|
{
|
|
TEST_ASSERT_EQUAL_FLOAT(adcval.solar_voltage, round(hv_terminal.bus->voltage * 10) / 10);
|
|
TEST_ASSERT_EQUAL_FLOAT(adcval.dcdc_current / adcval.solar_voltage * adcval.battery_voltage,
|
|
-round(hv_terminal.current * 10) / 10);
|
|
}
|
|
|
|
void check_bat_terminal_readings()
|
|
{
|
|
TEST_ASSERT_EQUAL_FLOAT(adcval.battery_voltage, round(lv_terminal.bus->voltage * 10) / 10);
|
|
TEST_ASSERT_EQUAL_FLOAT(adcval.dcdc_current - adcval.load_current,
|
|
round(lv_terminal.current * 10) / 10);
|
|
}
|
|
|
|
void check_load_terminal_readings()
|
|
{
|
|
TEST_ASSERT_EQUAL_FLOAT(adcval.battery_voltage, round(load_terminal.bus->voltage * 10) / 10);
|
|
TEST_ASSERT_EQUAL_FLOAT(adcval.load_current, round(load_terminal.current * 10) / 10);
|
|
}
|
|
|
|
void check_lv_bus_int_readings()
|
|
{
|
|
TEST_ASSERT_EQUAL_FLOAT(adcval.battery_voltage, round(dcdc_port_lv.bus->voltage * 10) / 10);
|
|
TEST_ASSERT_EQUAL_FLOAT(adcval.dcdc_current, round(dcdc_port_lv.current * 10) / 10);
|
|
}
|
|
|
|
void check_temperature_readings()
|
|
{
|
|
TEST_ASSERT_EQUAL_FLOAT(adcval.bat_temperature, round(charger.bat_temperature * 10) / 10);
|
|
}
|
|
|
|
/** ADC conversion test
|
|
*
|
|
* Purpose: Check if raw data from 2 voltage and 2 current measurements are converted
|
|
* to calculated voltage/current measurements of different DC buses
|
|
*/
|
|
void adc_tests()
|
|
{
|
|
adcval.bat_temperature = 25;
|
|
adcval.battery_voltage = 12;
|
|
adcval.dcdc_current = 3;
|
|
adcval.internal_temperature = 25;
|
|
adcval.load_current = 1;
|
|
adcval.mcu_temperature = 25;
|
|
adcval.solar_voltage = 30;
|
|
prepare_adc_readings(adcval);
|
|
|
|
// call original update_measurements function
|
|
update_measurements();
|
|
|
|
UNITY_BEGIN();
|
|
|
|
RUN_TEST(check_solar_terminal_readings);
|
|
RUN_TEST(check_bat_terminal_readings);
|
|
RUN_TEST(check_load_terminal_readings);
|
|
RUN_TEST(check_lv_bus_int_readings);
|
|
|
|
//RUN_TEST(check_temperature_readings); // TODO
|
|
|
|
UNITY_END();
|
|
} |