MPPT charger firmware structure
Important remarks
-
Do not use mbed Ticker class, as it disturbs the timer settings and might cause the charge controller to crash. In addition to that, it contains a lot of overhead and is not very efficient. Timers are programmed bare metal.
-
The PWM signal generation for the DC/DC controller inside the charge controller is done in the file half_bridge_xxx.cpp and dcdc.cpp. Most of the dangerous functions which could turn your MOSFETs into magic smoke are implemented here, so don't touch it unless you know what you're doing.
Toolchain and flashing instructions
See the Libre Solar website for a detailed instruction how to develop software and flash new firmware.
Timer configuration
- mbed us_ticker (cannot be changed)
- TIM2 for STM32F0
- TIM21 for STM32L0
- PWM generation for DC/DC half bridge (50-70 kHz)
- TIM1 for STM32F0 (advanced timer)
- TIM3 for STM32L0 (standard timer)
- ADC and DMA (1 kHz)
- TIM15 for STM32F0
- TIM6 for STM32L0
- DC/DC control function (10 Hz)
- TIM16 for STM32F0
- TIM7 for STM32L0
- LED light control
- TIM17 for STM32F0
- TIM22 for STM32L0