https://docs.zephyrproject.org/latest/guides/west/workspaces.html Previously, west manifest and CMake entry point were in zephyr subfolder as required for PlatformIO. As PlatformIO support was dropped, we can follow the default Zephyr folder structure more closely. The application is built and flashed from app subfolder, where as unit tests are run from tests subfolder.
63 lines
2.0 KiB
YAML
63 lines
2.0 KiB
YAML
# Copyright (c) The Libre Solar Project Contributors
|
|
# SPDX-License-Identifier: Apache-2.0
|
|
|
|
description: Generic charge controller device setup
|
|
|
|
compatible: "charge-controller"
|
|
|
|
properties:
|
|
type:
|
|
type: string
|
|
required: true
|
|
description: Device type
|
|
version-str:
|
|
type: string
|
|
required: true
|
|
description: Hardware version number (human-readable)
|
|
version-num:
|
|
type: int
|
|
required: true
|
|
description: Hardware version number (usable in preprocessor defines)
|
|
hs-voltage-max:
|
|
type: int
|
|
required: true
|
|
description: Maximum voltage at high-side (typically PV input) in volts
|
|
ls-voltage-max:
|
|
type: int
|
|
required: true
|
|
description: Maximum voltage at low-side (typically battery) in volts
|
|
dcdc-current-max:
|
|
type: int
|
|
description: Maximum inductor current in amps (if existing in the charge controller)
|
|
internal-tref-max:
|
|
type: int
|
|
default: 50
|
|
description: |
|
|
Internal reference temperature at full load (°C)
|
|
|
|
This value is used for model-based control of overcurrent protection. It represents
|
|
the steady-state internal temperature for max. continuous current at ambient
|
|
temperature of 25°C. Default value is conservative and can be overwritten in PCB
|
|
configuration.
|
|
mosfets-tj-max:
|
|
type: int
|
|
default: 120
|
|
description: |
|
|
Maximum Tj of MOSFETs (°C)
|
|
|
|
This value is used for model-based control of overcurrent protection. It represents
|
|
the steady-state junction temperature for max. continuous current at ambient
|
|
temperature of 25°C.
|
|
mosfets-tau-ja:
|
|
type: int
|
|
default: 5
|
|
description: |
|
|
Thermal time constant junction to ambient (s)
|
|
|
|
This value is used for model-based control of overcurrent protection. It does not reflect
|
|
the much lower MOSFET-internal time constant junction to case, but includes thermal
|
|
inertia of the board.
|
|
|
|
Around 5s seems to be a good conservative estimation for 5x6 type SMD MOSFETs. Take larger
|
|
values for big heat sinks.
|