/* LibreSolar MPPT charge controller firmware * Copyright (c) 2016-2018 Martin Jäger (www.libre.solar) * * Licensed under the Apache License, Version 2.0 (the "License"); * you may not use this file except in compliance with the License. * You may obtain a copy of the License at * * http://www.apache.org/licenses/LICENSE-2.0 * * Unless required by applicable law or agreed to in writing, software * distributed under the License is distributed on an "AS IS" BASIS, * WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. * See the License for the specific language governing permissions and * limitations under the License. */ #include "charger.h" #include "config.h" #include "pcb.h" #include "half_bridge.h" #include "log.h" // private function void _enter_state(battery_t* bat, int next_state) { //printf("Enter State: %d\n", next_state); bat->time_state_changed = time(NULL); bat->state = next_state; } /***************************************************************************** * Charger state machine ## Idle Initial state of the charge controller. If the solar voltage is high enough and the battery is not full, charging in CC mode is started. ## CC / bulk charging The battery is charged with maximum possible current (MPPT algorithm is active) until the CV voltage limit is reached. ## CV / absorption charging Lead-acid batteries are charged for some time using a slightly higher charge voltage. After a current cutoff limit or a time limit is reached, the charger goes into trickle or equalization mode for lead-acid batteries or back into Standby for Li-ion batteries. ## Trickle charging This mode is kept forever for a lead-acid battery and keeps the battery at full state of charge. If too much power is drawn from the battery, the charger switches back into CC / bulk charging mode. ## Equalization charging This mode is only used for lead-acid batteries after several deep-discharge cycles or a very long period of time with no equalization. Voltage is increased to 15V or above, so care must be taken for the other system components attached to the battery. (currently, no equalization charging is enabled in the software) */ void charger_state_machine(power_port_t *port, battery_t *bat, float voltage, float current) { //printf("time_state_change = %d, time = %d, v_bat = %f, i_bat = %f\n", bat->time_state_changed, time(NULL), voltage, current); // Load management // battery port input state (i.e. battery discharging direction) defines load state if (port->input_allowed == true && voltage < bat->cell_voltage_load_disconnect * bat->num_cells) { port->input_allowed = false; bat->num_deep_discharges++; if (bat->useable_capacity < 0.1) { bat->useable_capacity = bat->discharged_Ah; } else { // slowly adapt new measurements with low-pass filter bat->useable_capacity = 0.8 * bat->useable_capacity + 0.2 * bat->discharged_Ah; } // simple SOH estimation bat->soh = bat->useable_capacity / bat->nominal_capacity; } if (voltage >= bat->cell_voltage_load_reconnect * bat->num_cells) { port->input_allowed = true; } // state machine switch (bat->state) { case CHG_STATE_IDLE: { if (voltage < bat->num_cells * bat->cell_voltage_recharge && (time(NULL) - bat->time_state_changed) > bat->time_limit_recharge) { port->voltage_output_target = bat->num_cells * bat->cell_voltage_max; port->current_output_max = bat->charge_current_max; port->output_allowed = true; bat->full = false; _enter_state(bat, CHG_STATE_CC); } break; } case CHG_STATE_CC: { if (voltage > port->voltage_output_target) { port->voltage_output_target = bat->num_cells * bat->cell_voltage_max; _enter_state(bat, CHG_STATE_CV); } break; } case CHG_STATE_CV: { if (voltage >= port->voltage_output_target) { bat->time_voltage_limit_reached = time(NULL); } // cut-off limit reached because battery full (i.e. CV mode still // reached by available solar power within last 2s) or CV period long enough? if ((current < bat->current_cutoff_CV && (time(NULL) - bat->time_voltage_limit_reached) < 2) || (time(NULL) - bat->time_state_changed) > bat->time_limit_CV) { bat->full = true; bat->num_full_charges++; bat->discharged_Ah = 0; // reset coulomb counter if (bat->equalization_enabled) { // TODO: additional conditions! port->voltage_output_target = bat->num_cells * bat->cell_voltage_equalization; port->current_output_max = bat->current_limit_equalization; _enter_state(bat, CHG_STATE_EQUALIZATION); } else if (bat->trickle_enabled) { port->voltage_output_target = bat->num_cells * bat->cell_voltage_trickle; _enter_state(bat, CHG_STATE_TRICKLE); } else { port->current_output_max = 0; port->output_allowed = false; _enter_state(bat, CHG_STATE_IDLE); } } break; } case CHG_STATE_TRICKLE: { if (voltage >= port->voltage_output_target) { bat->time_voltage_limit_reached = time(NULL); } if (time(NULL) - bat->time_voltage_limit_reached > bat->time_trickle_recharge) { port->current_output_max = bat->charge_current_max; port->voltage_output_target = bat->num_cells * bat->cell_voltage_max; bat->full = false; _enter_state(bat, CHG_STATE_CC); } // assumption: trickle does not harm the battery --> never go back to idle // (for Li-ion battery: disable trickle!) break; } } }