/* * Copyright (c) 2018 Martin Jäger / Libre Solar * * SPDX-License-Identifier: Apache-2.0 */ #include "tests.h" #include "daq.h" #include "daq_stub.h" #include "main.h" #include static AdcValues adcval; // testing only for 2 values void check_filtering() { // reset values clear_adc_filtered(); // collect 1000 samples to update filtered values for (int s = 0; s < 1000; s++) { for (int i = 0; i < NUM_ADC_CH; i++) { adc_update_value(i); } } uint32_t adc_filtered_bak[NUM_ADC_CH]; adc_filtered_bak[ADC_POS_VREF_MCU] = get_adc_filtered(ADC_POS_VREF_MCU); adc_filtered_bak[ADC_POS_V_SOLAR] = get_adc_filtered(ADC_POS_V_SOLAR); // overwrite filtered values prepare_adc_filtered(); TEST_ASSERT_EQUAL(get_adc_filtered(ADC_POS_VREF_MCU), adc_filtered_bak[ADC_POS_VREF_MCU]); TEST_ASSERT_EQUAL(get_adc_filtered(ADC_POS_V_SOLAR), adc_filtered_bak[ADC_POS_V_SOLAR]); } void check_solar_terminal_readings() { TEST_ASSERT_EQUAL_FLOAT(adcval.solar_voltage, round(hv_terminal.voltage * 10) / 10); TEST_ASSERT_EQUAL_FLOAT(adcval.dcdc_current / adcval.solar_voltage * adcval.battery_voltage, -round(hv_terminal.current * 10) / 10); } void check_bat_terminal_readings() { TEST_ASSERT_EQUAL_FLOAT(adcval.battery_voltage, round(lv_terminal.voltage * 10) / 10); TEST_ASSERT_EQUAL_FLOAT(adcval.dcdc_current - adcval.load_current, round(lv_terminal.current * 10) / 10); } void check_load_terminal_readings() { TEST_ASSERT_EQUAL_FLOAT(adcval.battery_voltage, round(load_terminal.voltage * 10) / 10); TEST_ASSERT_EQUAL_FLOAT(adcval.load_current, round(load_terminal.current * 10) / 10); } void check_lv_bus_int_readings() { TEST_ASSERT_EQUAL_FLOAT(adcval.battery_voltage, round(dcdc_lv_port.voltage * 10) / 10); TEST_ASSERT_EQUAL_FLOAT(adcval.dcdc_current, round(dcdc_lv_port.current * 10) / 10); } void check_temperature_readings() { TEST_ASSERT_EQUAL_FLOAT(adcval.bat_temperature, round(charger.bat_temperature * 10) / 10); } void adc_alert_undervoltage_triggering() { dev_stat.clear_error(ERR_ANY_ERROR); battery_conf_init(&bat_conf, BAT_TYPE_LFP, 4, 100); daq_set_lv_alerts(bat_conf.voltage_absolute_max, bat_conf.voltage_absolute_min); prepare_adc_filtered(); adc_update_value(ADC_POS_V_BAT); // undervoltage test adcval.battery_voltage = bat_conf.voltage_absolute_min - 0.1; prepare_adc_readings(adcval); adc_update_value(ADC_POS_V_BAT); TEST_ASSERT_EQUAL(false, dev_stat.has_error(ERR_LOAD_VOLTAGE_DIP)); adc_update_value(ADC_POS_V_BAT); load.control(); TEST_ASSERT_EQUAL(true, dev_stat.has_error(ERR_LOAD_VOLTAGE_DIP)); TEST_ASSERT_EQUAL(false, load.pgood); TEST_ASSERT_EQUAL(LOAD_STATE_OFF_OVERCURRENT, load.state); // reset values adcval.battery_voltage = 13; prepare_adc_readings(adcval); prepare_adc_filtered(); daq_update(); charger.discharge_control(&bat_conf); TEST_ASSERT_EQUAL(false, dev_stat.has_error(ERR_BAT_UNDERVOLTAGE)); } void adc_alert_overvoltage_triggering() { dev_stat.clear_error(ERR_ANY_ERROR); battery_conf_init(&bat_conf, BAT_TYPE_LFP, 4, 100); daq_set_lv_alerts(bat_conf.voltage_absolute_max, bat_conf.voltage_absolute_min); prepare_adc_filtered(); adc_update_value(ADC_POS_V_BAT); dcdc.state = DCDC_STATE_MPPT; // overvoltage test adcval.battery_voltage = bat_conf.voltage_absolute_max + 0.1; prepare_adc_readings(adcval); adc_update_value(ADC_POS_V_BAT); TEST_ASSERT_EQUAL(false, dev_stat.has_error(ERR_BAT_OVERVOLTAGE)); adc_update_value(ADC_POS_V_BAT); TEST_ASSERT_EQUAL(true, dev_stat.has_error(ERR_BAT_OVERVOLTAGE)); TEST_ASSERT_EQUAL(false, pwm_switch.active()); TEST_ASSERT_EQUAL(DCDC_STATE_OFF, dcdc.state); // reset values adcval.battery_voltage = 12; prepare_adc_readings(adcval); prepare_adc_filtered(); daq_update(); charger.time_state_changed = time(NULL) - bat_conf.time_limit_recharge - 1; charger.charge_control(&bat_conf); TEST_ASSERT_EQUAL(false, dev_stat.has_error(ERR_BAT_OVERVOLTAGE)); } void adc_alert_overflow_prevention() { // try to set an alert that overflows the 12-bit ADC resolution uint16_t limit = adc_get_alert_limit(1, 4097); TEST_ASSERT_EQUAL_HEX((uint16_t)(UINT16_MAX << 4), limit); } /** Data acquisition tests * * Purpose: Check if raw data from 2 voltage and 2 current measurements are converted * to calculated voltage/current measurements of different DC buses */ void daq_tests() { adcval.bat_temperature = 25; adcval.battery_voltage = 12; adcval.dcdc_current = 3; adcval.internal_temperature = 25; adcval.load_current = 1; adcval.solar_voltage = 30; prepare_adc_readings(adcval); UNITY_BEGIN(); RUN_TEST(check_filtering); // call original daq_update function daq_update(); RUN_TEST(check_solar_terminal_readings); RUN_TEST(check_bat_terminal_readings); RUN_TEST(check_load_terminal_readings); RUN_TEST(check_lv_bus_int_readings); //RUN_TEST(check_temperature_readings); // TODO RUN_TEST(adc_alert_undervoltage_triggering); RUN_TEST(adc_alert_overvoltage_triggering); RUN_TEST(adc_alert_overflow_prevention); UNITY_END(); }