Commit Graph
6 Commits
Author SHA1 Message Date
Martin Jaeger f254c77ab6 Refactoring of load control and state machine
- State machine and control merged to one function
- Load states marked as deprecated, global error flags used instead
- Reduced duplicated code and made load control function easier to read
2019-11-11 09:35:26 +01:00
hogthrob d1ff837c5e Overvoltage limit overflow fix (#80)
The bat config calculation did calculate the absolute max voltage
too high, it was doing an unnecessary multiplication.
This triggered an issue in the voltage limit set code, which did not
handle the overflow of the 16bit limit value properly.

Both are fixed now. We limit the limit value to what the ADC is able
to deliver, so that we detect overvoltage for sure, even if the setting
is out of ADC range.
2019-11-10 17:55:43 +01:00
hogthrob ba7d379225 Refactored adc_dma.cpp for readability (#76)
- replaced the lengthy adc value formulas with respective functions
  to ease reading
- removed unecessary casts for alert callbacks
- added static to the internal global variables in order to hide them from the
  other compilation units
2019-11-09 23:13:00 +01:00
Martin Jaeger 5e3181f5e5 Distinguishing between OV and UV alerts, inhibit added
- During overvoltage alerts, only power sources (PWM switch and DC/DC are
  switched off), undervoltage only switches load off
- Alert inhibit added to prevent switching off during PWM switch startup
2019-11-05 18:43:33 +01:00
Martin Jaeger 7874b8b4d6 ADC alerts and emergency stop functions added
Check for overvoltage/undervoltage conditions after each ADC reading cycle and
trigger alert (stopping DC/DC, PWM switch and load output) if limits exceeded.
2019-11-04 18:12:00 +01:00
Martin Jaeger 7412b11002 ADC filtering in separate function + unit-tests 2019-11-04 18:02:43 +01:00