Rationale: Logging is used for historic data, but error flags are instantaneous data. Device status
is more generic and now contains also the internal temperature measurement.
- MCU temperature was renamed to internal_temperature
- NTC at board edge senses temperatures far above battery / ambient temperature at high loads and is now ignored
- Battery temperature always assumed 25ÂC unless external sensor is detected
Previous naming with chg/dis didn't make much sense e.g. for load output or solar panels. Voltage
targets are now named with source or sink. Current limits are defined based on their direction
(negative or positive). ASCII art graphic added for better explanation of passive sign convention.
Reason: Previous idea with storing the voltage only once and not in every port
doesn't work well for droop settings, e.g. the DC/DC output port doesn't know
the actual battery current, which should be used to calculate the droop caued
by wire resistance.