Use methods to set/clear/query error flags (#71)
Easier to read, quicker to write (if using code completion), no performance loss due to inlining.
This commit is contained in:
+3
-3
@@ -176,11 +176,11 @@ void update_measurements()
|
||||
(TSENSE_CAL2 - TSENSE_CAL1) * (adcval - TSENSE_CAL1) + TSENSE_CAL1_VALUE;
|
||||
|
||||
if (dev_stat.internal_temp > 80) {
|
||||
dev_stat.error_flags |= 1U << ERR_INT_OVERTEMP;
|
||||
dev_stat.set_error(ERR_INT_OVERTEMP);
|
||||
}
|
||||
else if (dev_stat.internal_temp < 70 && (dev_stat.error_flags & (1U << ERR_INT_OVERTEMP))) {
|
||||
else if (dev_stat.internal_temp < 70 && (dev_stat.has_error(ERR_INT_OVERTEMP))) {
|
||||
// remove error flag with hysteresis of 10°C
|
||||
dev_stat.error_flags &= ~(1U << ERR_INT_OVERTEMP);
|
||||
dev_stat.clear_error(ERR_INT_OVERTEMP);
|
||||
}
|
||||
// else: keep previous setting
|
||||
}
|
||||
|
||||
+10
-10
@@ -277,7 +277,7 @@ void Charger::discharge_control(BatConf *bat_conf)
|
||||
// low state of charge
|
||||
port->neg_current_limit = 0;
|
||||
num_deep_discharges++;
|
||||
dev_stat.error_flags |= (1 << ERR_BAT_UNDERVOLTAGE);
|
||||
dev_stat.set_error(ERR_BAT_UNDERVOLTAGE);
|
||||
|
||||
if (usable_capacity < 0.1) {
|
||||
// reset to measured value if discharged the first time
|
||||
@@ -297,11 +297,11 @@ void Charger::discharge_control(BatConf *bat_conf)
|
||||
}
|
||||
else if (bat_temperature > bat_conf->discharge_temp_max) {
|
||||
port->neg_current_limit = 0;
|
||||
dev_stat.error_flags |= (1 << ERR_BAT_DIS_OVERTEMP);
|
||||
dev_stat.set_error(ERR_BAT_DIS_OVERTEMP);
|
||||
}
|
||||
else if (bat_temperature < bat_conf->discharge_temp_min) {
|
||||
port->neg_current_limit = 0;
|
||||
dev_stat.error_flags |= (1 << ERR_BAT_DIS_UNDERTEMP);
|
||||
dev_stat.set_error(ERR_BAT_DIS_UNDERTEMP);
|
||||
}
|
||||
}
|
||||
else {
|
||||
@@ -316,9 +316,9 @@ void Charger::discharge_control(BatConf *bat_conf)
|
||||
port->neg_current_limit = -bat_conf->discharge_current_max;
|
||||
|
||||
// delete all discharge error flags
|
||||
dev_stat.error_flags &= ~(1 << ERR_BAT_DIS_OVERTEMP);
|
||||
dev_stat.error_flags &= ~(1 << ERR_BAT_DIS_UNDERTEMP);
|
||||
dev_stat.error_flags &= ~(1 << ERR_BAT_UNDERVOLTAGE);
|
||||
dev_stat.clear_error(ERR_BAT_DIS_OVERTEMP);
|
||||
dev_stat.clear_error(ERR_BAT_DIS_UNDERTEMP);
|
||||
dev_stat.clear_error(ERR_BAT_UNDERVOLTAGE);
|
||||
}
|
||||
}
|
||||
}
|
||||
@@ -328,12 +328,12 @@ void Charger::charge_control(BatConf *bat_conf)
|
||||
// check battery temperature for charging direction
|
||||
if (bat_temperature > bat_conf->charge_temp_max) {
|
||||
port->pos_current_limit = 0;
|
||||
dev_stat.error_flags |= (1 << ERR_BAT_CHG_OVERTEMP);
|
||||
dev_stat.set_error(ERR_BAT_CHG_OVERTEMP);
|
||||
enter_state(CHG_STATE_IDLE);
|
||||
}
|
||||
else if (bat_temperature < bat_conf->charge_temp_min) {
|
||||
port->pos_current_limit = 0;
|
||||
dev_stat.error_flags |= (1 << ERR_BAT_CHG_UNDERTEMP);
|
||||
dev_stat.set_error(ERR_BAT_CHG_UNDERTEMP);
|
||||
enter_state(CHG_STATE_IDLE);
|
||||
}
|
||||
|
||||
@@ -349,8 +349,8 @@ void Charger::charge_control(BatConf *bat_conf)
|
||||
bat_conf->temperature_compensation * (bat_temperature - 25));
|
||||
port->pos_current_limit = bat_conf->charge_current_max;
|
||||
full = false;
|
||||
dev_stat.error_flags &= ~(1 << ERR_BAT_CHG_OVERTEMP);
|
||||
dev_stat.error_flags &= ~(1 << ERR_BAT_CHG_UNDERTEMP);
|
||||
dev_stat.clear_error(ERR_BAT_CHG_OVERTEMP);
|
||||
dev_stat.clear_error(ERR_BAT_CHG_UNDERTEMP);
|
||||
enter_state(CHG_STATE_BULK);
|
||||
}
|
||||
break;
|
||||
|
||||
@@ -90,6 +90,10 @@ public:
|
||||
// instantaneous device-level data
|
||||
uint32_t error_flags; ///< Currently detected errors
|
||||
float internal_temp; ///< Internal temperature (measured in MCU)
|
||||
|
||||
void set_error(ErrorFlag e) { error_flags |= (1U << e); }
|
||||
void clear_error(ErrorFlag e) { error_flags &= ~(1U << e); }
|
||||
bool has_error(ErrorFlag e) { return (error_flags & (1U << e)) != 0; }
|
||||
};
|
||||
|
||||
#endif /* DEVICE_STATUS_H */
|
||||
|
||||
Reference in New Issue