Separate load and USB out, improve state handling
Identified issues: - The load output and USB charging port shared the same state machine, which did not allow to set different switch-off thresholds. - Load error codes were global, so it was not possible to have multiple load instances. This commit introduces load-specific error_flags, makes the LoadOutput class inherit from PowerPort (to improve code readability), separates the load driver better from higher level implementation and adds a second LoadOutput object for the USB charging port.
This commit is contained in:
+5
-6
@@ -7,7 +7,7 @@
|
||||
#include "tests.h"
|
||||
#include "daq.h"
|
||||
#include "daq_stub.h"
|
||||
|
||||
#include "helper.h"
|
||||
#include "setup.h"
|
||||
|
||||
#include <stdint.h>
|
||||
@@ -54,8 +54,8 @@ void check_bat_terminal_readings()
|
||||
|
||||
void check_load_terminal_readings()
|
||||
{
|
||||
TEST_ASSERT_EQUAL_FLOAT(adcval.battery_voltage, round(load_terminal.bus->voltage * 10) / 10);
|
||||
TEST_ASSERT_EQUAL_FLOAT(adcval.load_current, round(load_terminal.current * 10) / 10);
|
||||
TEST_ASSERT_EQUAL_FLOAT(adcval.battery_voltage, round(load.bus->voltage * 10) / 10);
|
||||
TEST_ASSERT_EQUAL_FLOAT(adcval.load_current, round(load.current * 10) / 10);
|
||||
}
|
||||
|
||||
void check_lv_bus_int_readings()
|
||||
@@ -84,9 +84,8 @@ void adc_alert_undervoltage_triggering()
|
||||
TEST_ASSERT_EQUAL(false, dev_stat.has_error(ERR_LOAD_VOLTAGE_DIP));
|
||||
adc_update_value(ADC_POS_V_LOW);
|
||||
load.control();
|
||||
TEST_ASSERT_EQUAL(true, dev_stat.has_error(ERR_LOAD_VOLTAGE_DIP));
|
||||
TEST_ASSERT_EQUAL(false, load.pgood);
|
||||
TEST_ASSERT_EQUAL(LOAD_STATE_OFF_OVERCURRENT, load.state);
|
||||
TEST_ASSERT_EQUAL(true, flags_check(&load.error_flags, ERR_LOAD_VOLTAGE_DIP));
|
||||
TEST_ASSERT_EQUAL(LOAD_STATE_OFF, load.state);
|
||||
|
||||
// reset values
|
||||
adcval.battery_voltage = 13;
|
||||
|
||||
Reference in New Issue