DC bus integrated into PowerPort class

Reason: Previous idea with storing the voltage only once and not in every port
doesn't work well for droop settings, e.g. the DC/DC output port doesn't know
the actual battery current, which should be used to calculate the droop caued
by wire resistance.
This commit is contained in:
Martin Jaeger
2019-10-22 18:23:19 +02:00
parent a89ac7ff4b
commit f879dc9c5d
22 changed files with 191 additions and 234 deletions
+4 -4
View File
@@ -9,7 +9,7 @@
void reset_counters_at_start_of_day()
{
solar_terminal.bus->voltage = bat_terminal.bus->voltage - 1;
solar_terminal.voltage = bat_terminal.voltage - 1;
log_data.day_counter = 0;
@@ -37,7 +37,7 @@ void reset_counters_at_start_of_day()
TEST_ASSERT_EQUAL(0, log_data.day_counter);
// now solar power comes back
solar_terminal.bus->voltage = bat_terminal.bus->voltage + 1;
solar_terminal.voltage = bat_terminal.voltage + 1;
log_update_energy(&log_data);
// day counter should be increased and daily energy counters reset
@@ -50,14 +50,14 @@ void reset_counters_at_start_of_day()
void log_new_solar_voltage_max()
{
solar_terminal.bus->voltage = 40;
solar_terminal.voltage = 40;
log_update_min_max_values(&log_data);
TEST_ASSERT_EQUAL(40, log_data.solar_voltage_max);
}
void log_new_bat_voltage_max()
{
bat_terminal.bus->voltage = 31;
bat_terminal.voltage = 31;
log_update_min_max_values(&log_data);
TEST_ASSERT_EQUAL(31, log_data.battery_voltage_max);
}