DC bus integrated into PowerPort class

Reason: Previous idea with storing the voltage only once and not in every port
doesn't work well for droop settings, e.g. the DC/DC output port doesn't know
the actual battery current, which should be used to calculate the droop caued
by wire resistance.
This commit is contained in:
Martin Jaeger
2019-10-22 18:23:19 +02:00
parent a89ac7ff4b
commit f879dc9c5d
22 changed files with 191 additions and 234 deletions
+3 -7
View File
@@ -123,12 +123,8 @@ const data_object_t data_objects[] = {
{0x06, TS_OUTPUT, TS_READ_ALL, TS_T_UINT16, 0, (void*) &(charger.soc), "SOC_%"}, // output will be uint8_t
// battery related data objects
{0x70, TS_OUTPUT, TS_READ_ALL, TS_T_FLOAT32, 2, (void*) &(BATTERY_BUS.voltage), "Bat_V"}, // TODO: reference to bat_terminal
#if FEATURE_PWM_SWITCH
{0x71, TS_OUTPUT, TS_READ_ALL, TS_T_FLOAT32, 2, (void*) &(pwm_bus.voltage), "Solar_V"},
#else
{0x71, TS_OUTPUT, TS_READ_ALL, TS_T_FLOAT32, 2, (void*) &(SOLAR_BUS.voltage), "Solar_V"},
#endif
{0x70, TS_OUTPUT, TS_READ_ALL, TS_T_FLOAT32, 2, (void*) &(bat_terminal.voltage), "Bat_V"},
{0x71, TS_OUTPUT, TS_READ_ALL, TS_T_FLOAT32, 2, (void*) &(solar_terminal.voltage), "Solar_V"},
{0x72, TS_OUTPUT, TS_READ_ALL, TS_T_FLOAT32, 2, (void*) &(bat_terminal.current), "Bat_A"},
{0x73, TS_OUTPUT, TS_READ_ALL, TS_T_FLOAT32, 2, (void*) &(load_terminal.current), "Load_A"},
{0x74, TS_OUTPUT, TS_READ_ALL, TS_T_FLOAT32, 1, (void*) &(charger.bat_temperature), "Bat_degC"},
@@ -142,7 +138,7 @@ const data_object_t data_objects[] = {
{0x79, TS_OUTPUT, TS_READ_ALL, TS_T_UINT16, 0, (void*) &(dcdc.state), "DCDCState"},
#endif
{0x7A, TS_OUTPUT, TS_READ_ALL, TS_T_FLOAT32, 2, (void*) &(solar_terminal.current), "Solar_A"},
{0x7B, TS_OUTPUT, TS_READ_ALL, TS_T_FLOAT32, 2, (void*) &(BATTERY_BUS.chg_voltage_target), "BatTarget_V"}, // TODO: reference to bat_terminal
{0x7B, TS_OUTPUT, TS_READ_ALL, TS_T_FLOAT32, 2, (void*) &(bat_terminal.chg_voltage_target), "BatTarget_V"},
{0x7C, TS_OUTPUT, TS_READ_ALL, TS_T_FLOAT32, 2, (void*) &(bat_terminal.chg_current_limit), "BatTarget_A"},
{0x7D, TS_OUTPUT, TS_READ_ALL, TS_T_FLOAT32, 2, (void*) &(bat_terminal.power), "Bat_W"},
{0x7E, TS_OUTPUT, TS_READ_ALL, TS_T_FLOAT32, 2, (void*) &(solar_terminal.power), "Solar_W"},