Battery discharging control restructured
- Discharging control separated from charger state machine - Unit-tests for discharging control added - DC bus chg/dis_enabled flags removed, control now only based on chge/dis_current_limit values - _current_max values renamed to _limit to make more clear that values for discharging direction must be negative - Load output struct now stores pointer to internal and external DC bus objects
This commit is contained in:
+5
-5
@@ -130,7 +130,7 @@ void pwm_switch_init(PwmSwitch *pwm_switch)
|
||||
void pwm_switch_control(PwmSwitch *pwm_switch, DcBus *solar_bus, DcBus *bat_bus)
|
||||
{
|
||||
if (_enabled) {
|
||||
if (bat_bus->chg_allowed == false || solar_bus->dis_allowed == false
|
||||
if (bat_bus->chg_current_limit == 0 || solar_bus->dis_current_limit == 0
|
||||
|| solar_bus->current > 0 // discharging battery into solar panel --> stop
|
||||
|| pwm_switch->enabled == false)
|
||||
{
|
||||
@@ -139,8 +139,8 @@ void pwm_switch_control(PwmSwitch *pwm_switch, DcBus *solar_bus, DcBus *bat_bus)
|
||||
printf("PWM charger stop.\n");
|
||||
}
|
||||
else if (bat_bus->voltage > (bat_bus->chg_voltage_target - bat_bus->chg_droop_res * bat_bus->current) // output voltage above target
|
||||
|| bat_bus->current > bat_bus->chg_current_max // output current limit exceeded
|
||||
|| solar_bus->current < solar_bus->dis_current_max) // input current (negative signs) above limit
|
||||
|| bat_bus->current > bat_bus->chg_current_limit // output current limit exceeded
|
||||
|| solar_bus->current < solar_bus->dis_current_limit) // input current (negative signs) above limit
|
||||
{
|
||||
// The gate driver switch-off time is quite high (fall time around 1ms), so very short
|
||||
// on or off periods (duty cycle close to 0 and 1) should be avoided
|
||||
@@ -169,10 +169,10 @@ void pwm_switch_control(PwmSwitch *pwm_switch, DcBus *solar_bus, DcBus *bat_bus)
|
||||
}
|
||||
}
|
||||
else {
|
||||
if (bat_bus->chg_allowed == true
|
||||
if (bat_bus->chg_current_limit > 0 // charging allowed
|
||||
&& bat_bus->voltage < bat_bus->chg_voltage_target
|
||||
&& bat_bus->voltage > bat_bus->chg_voltage_min
|
||||
&& solar_bus->dis_allowed == true
|
||||
&& solar_bus->dis_current_limit < 0 // dischraging allowed
|
||||
&& solar_bus->voltage > bat_bus->voltage + pwm_switch->offset_voltage_start
|
||||
&& time(NULL) > (pwm_switch->off_timestamp + pwm_switch->restart_interval)
|
||||
&& pwm_switch->enabled == true)
|
||||
|
||||