Battery discharging control restructured
- Discharging control separated from charger state machine - Unit-tests for discharging control added - DC bus chg/dis_enabled flags removed, control now only based on chge/dis_current_limit values - _current_max values renamed to _limit to make more clear that values for discharging direction must be negative - Load output struct now stores pointer to internal and external DC bus objects
This commit is contained in:
+4
-3
@@ -110,7 +110,7 @@ int main()
|
||||
battery_conf_overwrite(&bat_conf, &bat_conf_user); // initialize conf_user with same values
|
||||
charger_init(&charger);
|
||||
|
||||
load_init(&load, &load_terminal);
|
||||
load_init(&load, &lv_bus_int, &load_terminal);
|
||||
|
||||
#ifdef CHARGER_TYPE_PWM
|
||||
pwm_switch_init(&pwm_switch);
|
||||
@@ -189,11 +189,12 @@ int main()
|
||||
|
||||
//printf("Still alive... time: %d, mode: %d\n", (int)time(NULL), dcdc.mode);
|
||||
|
||||
charger_state_machine(bat_terminal, &bat_conf, &charger);
|
||||
battery_discharge_control(bat_terminal, &bat_conf, &charger);
|
||||
battery_charge_control(bat_terminal, &bat_conf, &charger);
|
||||
|
||||
charger_update_junction_bus(&lv_bus_int, bat_terminal, &load_terminal);
|
||||
|
||||
load_state_machine(&load, lv_terminal.dis_allowed);
|
||||
load_state_machine(&load);
|
||||
|
||||
eeprom_update();
|
||||
|
||||
|
||||
Reference in New Issue
Block a user