Battery discharging control restructured

- Discharging control separated from charger state machine
- Unit-tests for discharging control added
- DC bus chg/dis_enabled flags removed, control now only based on chge/dis_current_limit values
- _current_max values renamed to _limit to make more clear that values for discharging direction must be negative
- Load output struct now stores pointer to internal and external DC bus objects
This commit is contained in:
Martin Jaeger
2019-10-16 16:04:21 +02:00
parent cce6e2a9b3
commit f33146e9de
17 changed files with 217 additions and 102 deletions
+4 -3
View File
@@ -110,7 +110,7 @@ int main()
battery_conf_overwrite(&bat_conf, &bat_conf_user); // initialize conf_user with same values
charger_init(&charger);
load_init(&load, &load_terminal);
load_init(&load, &lv_bus_int, &load_terminal);
#ifdef CHARGER_TYPE_PWM
pwm_switch_init(&pwm_switch);
@@ -189,11 +189,12 @@ int main()
//printf("Still alive... time: %d, mode: %d\n", (int)time(NULL), dcdc.mode);
charger_state_machine(bat_terminal, &bat_conf, &charger);
battery_discharge_control(bat_terminal, &bat_conf, &charger);
battery_charge_control(bat_terminal, &bat_conf, &charger);
charger_update_junction_bus(&lv_bus_int, bat_terminal, &load_terminal);
load_state_machine(&load, lv_terminal.dis_allowed);
load_state_machine(&load);
eeprom_update();