Battery discharging control restructured

- Discharging control separated from charger state machine
- Unit-tests for discharging control added
- DC bus chg/dis_enabled flags removed, control now only based on chge/dis_current_limit values
- _current_max values renamed to _limit to make more clear that values for discharging direction must be negative
- Load output struct now stores pointer to internal and external DC bus objects
This commit is contained in:
Martin Jaeger
2019-10-16 16:04:21 +02:00
parent cce6e2a9b3
commit f33146e9de
17 changed files with 217 additions and 102 deletions
+7 -7
View File
@@ -80,7 +80,7 @@ int duty_cycle_delta(Dcdc *dcdc)
#if 0
printf("P: %.2f, P_prev: %.2f, v_in: %.2f, v_out: %.2f, i_in: %.2f, i_out: %.2f, v_chg_target: %.2f, i_chg_max: %.2f, PWM: %.1f, chg_state: %d\n",
out->power, dcdc->power_prev, in->voltage, out->voltage, in->current, out->current, out->chg_voltage_target,
out->chg_current_max, half_bridge_get_duty_cycle() * 100.0, dcdc->state);
out->chg_current_limit, half_bridge_get_duty_cycle() * 100.0, dcdc->state);
#endif
if (time(NULL) - dcdc->power_good_timestamp > 10 || // more than 10s low power
@@ -94,8 +94,8 @@ int duty_cycle_delta(Dcdc *dcdc)
dcdc->state = DCDC_STATE_CV;
pwr_inc_goal = -1; // decrease output power
}
else if (out->current > out->chg_current_max // output charge current limit exceeded
|| in->current < in->dis_current_max) // input current (negative signs) limit exceeded
else if (out->current > out->chg_current_limit // output charge current limit exceeded
|| in->current < in->dis_current_limit) // input current (negative signs) limit exceeded
{
dcdc->state = DCDC_STATE_CC;
pwr_inc_goal = -1; // decrease output power
@@ -136,19 +136,19 @@ int dcdc_check_start_conditions(Dcdc *dcdc)
return 0; // no energy transfer allowed
}
if (dcdc->lv_bus->chg_current_max > 0 &&
if (dcdc->lv_bus->chg_current_limit > 0 &&
dcdc->lv_bus->voltage < dcdc->lv_bus->chg_voltage_target &&
dcdc->lv_bus->voltage > dcdc->lv_bus->chg_voltage_min &&
dcdc->hv_bus->dis_current_max < 0 &&
dcdc->hv_bus->dis_current_limit < 0 &&
dcdc->hv_bus->voltage > dcdc->hv_bus->dis_voltage_start)
{
return 1; // start in buck mode allowed
}
if (dcdc->hv_bus->chg_current_max > 0 &&
if (dcdc->hv_bus->chg_current_limit > 0 &&
dcdc->hv_bus->voltage < dcdc->hv_bus->chg_voltage_target &&
dcdc->hv_bus->voltage > dcdc->hv_bus->chg_voltage_min &&
dcdc->lv_bus->dis_current_max < 0 &&
dcdc->lv_bus->dis_current_limit < 0 &&
dcdc->lv_bus->voltage > dcdc->lv_bus->dis_voltage_start)
{
return -1; // start in boost mode allowed