Battery discharging control restructured
- Discharging control separated from charger state machine - Unit-tests for discharging control added - DC bus chg/dis_enabled flags removed, control now only based on chge/dis_current_limit values - _current_max values renamed to _limit to make more clear that values for discharging direction must be negative - Load output struct now stores pointer to internal and external DC bus objects
This commit is contained in:
@@ -136,7 +136,7 @@ const data_object_t data_objects[] = {
|
||||
{0x79, TS_OUTPUT, TS_READ_ALL, TS_T_UINT16, 0, (void*) &(dcdc.state), "DCDCState"},
|
||||
{0x7A, TS_OUTPUT, TS_READ_ALL, TS_T_FLOAT32, 2, (void*) &(hv_terminal.current), "Solar_A"},
|
||||
{0x7B, TS_OUTPUT, TS_READ_ALL, TS_T_FLOAT32, 2, (void*) &(lv_terminal.chg_voltage_target), "BatTarget_V"},
|
||||
{0x7C, TS_OUTPUT, TS_READ_ALL, TS_T_FLOAT32, 2, (void*) &(lv_terminal.chg_current_max), "BatTarget_A"},
|
||||
{0x7C, TS_OUTPUT, TS_READ_ALL, TS_T_FLOAT32, 2, (void*) &(lv_terminal.chg_current_limit), "BatTarget_A"},
|
||||
{0x7D, TS_OUTPUT, TS_READ_ALL, TS_T_FLOAT32, 2, (void*) &(lv_terminal.power), "Bat_W"},
|
||||
{0x7E, TS_OUTPUT, TS_READ_ALL, TS_T_FLOAT32, 2, (void*) &(hv_terminal.power), "Solar_W"},
|
||||
{0x7F, TS_OUTPUT, TS_READ_ALL, TS_T_FLOAT32, 2, (void*) &(load_terminal.power), "Load_W"},
|
||||
|
||||