Battery discharging control restructured
- Discharging control separated from charger state machine - Unit-tests for discharging control added - DC bus chg/dis_enabled flags removed, control now only based on chge/dis_current_limit values - _current_max values renamed to _limit to make more clear that values for discharging direction must be negative - Load output struct now stores pointer to internal and external DC bus objects
This commit is contained in:
+28
-24
@@ -30,8 +30,9 @@ void battery_conf_init(BatConf *bat, BatType type, int num_cells, float nominal_
|
||||
{
|
||||
bat->nominal_capacity = nominal_capacity;
|
||||
|
||||
// common values for all batteries
|
||||
bat->charge_current_max = bat->nominal_capacity; // 1C should be safe for all batteries
|
||||
// 1C should be safe for all batteries
|
||||
bat->charge_current_max = bat->nominal_capacity;
|
||||
bat->discharge_current_max = bat->nominal_capacity;
|
||||
|
||||
bat->time_limit_recharge = 60; // sec
|
||||
bat->topping_duration = 120*60; // sec
|
||||
@@ -275,17 +276,15 @@ static void _enter_state(Charger* charger, int next_state)
|
||||
charger->state = next_state;
|
||||
}
|
||||
|
||||
void charger_state_machine(DcBus *bus, BatConf *bat_conf, Charger *charger)
|
||||
void battery_discharge_control(DcBus *bus, BatConf *bat_conf, Charger *charger)
|
||||
{
|
||||
//printf("time_state_change = %d, time = %d, v_bat = %f, i_bat = %f\n", charger->time_state_changed, time(NULL), voltage, current);
|
||||
|
||||
// load output state is defined by battery bus dis_allowed flag
|
||||
if (bus->dis_allowed == true
|
||||
if (bus->dis_current_limit < 0 // discharging allowed
|
||||
&& bus->voltage < charger->num_batteries *
|
||||
(bat_conf->voltage_load_disconnect - bus->current * bus->dis_droop_res))
|
||||
{
|
||||
// low state of charge
|
||||
bus->dis_allowed = false;
|
||||
bus->dis_current_limit = 0;
|
||||
charger->num_deep_discharges++;
|
||||
|
||||
if (charger->usable_capacity < 0.1) {
|
||||
@@ -303,12 +302,12 @@ void charger_state_machine(DcBus *bus, BatConf *bat_conf, Charger *charger)
|
||||
// simple SOH estimation
|
||||
charger->soh = charger->usable_capacity / bat_conf->nominal_capacity;
|
||||
}
|
||||
else if (bus->dis_allowed == true
|
||||
else if (bus->dis_current_limit < 0
|
||||
&& (charger->bat_temperature > bat_conf->discharge_temp_max
|
||||
|| charger->bat_temperature < bat_conf->discharge_temp_min))
|
||||
{
|
||||
// temperature limits exceeded
|
||||
bus->dis_allowed = false;
|
||||
bus->dis_current_limit = 0;
|
||||
}
|
||||
|
||||
if (bus->voltage >= charger->num_batteries *
|
||||
@@ -316,14 +315,19 @@ void charger_state_machine(DcBus *bus, BatConf *bat_conf, Charger *charger)
|
||||
&& charger->bat_temperature < bat_conf->discharge_temp_max - 1
|
||||
&& charger->bat_temperature > bat_conf->discharge_temp_min + 1)
|
||||
{
|
||||
bus->dis_allowed = true;
|
||||
// discharge current is stored as absolute value in bat_conf, but defined
|
||||
// as negative current for dc_bus
|
||||
bus->dis_current_limit = -bat_conf->discharge_current_max;
|
||||
}
|
||||
}
|
||||
|
||||
void battery_charge_control(DcBus *bus, BatConf *bat_conf, Charger *charger)
|
||||
{
|
||||
// check battery temperature for charging direction
|
||||
if (charger->bat_temperature > bat_conf->charge_temp_max
|
||||
|| charger->bat_temperature < bat_conf->charge_temp_min)
|
||||
{
|
||||
bus->chg_allowed = false;
|
||||
bus->chg_current_limit = 0;
|
||||
_enter_state(charger, CHG_STATE_IDLE);
|
||||
}
|
||||
|
||||
@@ -337,8 +341,7 @@ void charger_state_machine(DcBus *bus, BatConf *bat_conf, Charger *charger)
|
||||
{
|
||||
bus->chg_voltage_target = charger->num_batteries * (bat_conf->topping_voltage +
|
||||
bat_conf->temperature_compensation * (charger->bat_temperature - 25));
|
||||
bus->chg_current_max = bat_conf->charge_current_max;
|
||||
bus->chg_allowed = true;
|
||||
bus->chg_current_limit = bat_conf->charge_current_max;
|
||||
charger->full = false;
|
||||
_enter_state(charger, CHG_STATE_BULK);
|
||||
}
|
||||
@@ -385,7 +388,7 @@ void charger_state_machine(DcBus *bus, BatConf *bat_conf, Charger *charger)
|
||||
>= bat_conf->equalization_trigger_deep_cycles))
|
||||
{
|
||||
bus->chg_voltage_target = bat_conf->equalization_voltage;
|
||||
bus->chg_current_max = bat_conf->equalization_current_limit;
|
||||
bus->chg_current_limit = bat_conf->equalization_current_limit;
|
||||
_enter_state(charger, CHG_STATE_EQUALIZATION);
|
||||
}
|
||||
else if (bat_conf->trickle_enabled) {
|
||||
@@ -394,8 +397,7 @@ void charger_state_machine(DcBus *bus, BatConf *bat_conf, Charger *charger)
|
||||
_enter_state(charger, CHG_STATE_TRICKLE);
|
||||
}
|
||||
else {
|
||||
bus->chg_current_max = 0;
|
||||
bus->chg_allowed = false;
|
||||
bus->chg_current_limit = 0;
|
||||
_enter_state(charger, CHG_STATE_IDLE);
|
||||
}
|
||||
}
|
||||
@@ -414,7 +416,7 @@ void charger_state_machine(DcBus *bus, BatConf *bat_conf, Charger *charger)
|
||||
|
||||
if (time(NULL) - charger->time_voltage_limit_reached > bat_conf->trickle_recharge_time)
|
||||
{
|
||||
bus->chg_current_max = bat_conf->charge_current_max;
|
||||
bus->chg_current_limit = bat_conf->charge_current_max;
|
||||
charger->full = false;
|
||||
_enter_state(charger, CHG_STATE_BULK);
|
||||
}
|
||||
@@ -442,8 +444,7 @@ void charger_state_machine(DcBus *bus, BatConf *bat_conf, Charger *charger)
|
||||
_enter_state(charger, CHG_STATE_TRICKLE);
|
||||
}
|
||||
else {
|
||||
bus->chg_current_max = 0;
|
||||
bus->chg_allowed = false;
|
||||
bus->chg_current_limit = 0;
|
||||
_enter_state(charger, CHG_STATE_IDLE);
|
||||
}
|
||||
}
|
||||
@@ -456,18 +457,16 @@ void battery_init_dc_bus(DcBus *bus, BatConf *bat, unsigned int num_batteries)
|
||||
{
|
||||
unsigned int n = (num_batteries == 2 ? 2 : 1); // only 1 or 2 allowed
|
||||
|
||||
bus->dis_allowed = true;
|
||||
bus->dis_voltage_start = bat->voltage_load_reconnect * n;
|
||||
bus->dis_voltage_stop = bat->voltage_load_disconnect * n;
|
||||
bus->dis_current_max = -bat->charge_current_max; // TODO: discharge current
|
||||
bus->dis_current_limit = -bat->discharge_current_max;
|
||||
|
||||
// negative sign for compensation of actual resistance
|
||||
bus->dis_droop_res = -(bat->internal_resistance + -bat->wire_resistance) * n;
|
||||
|
||||
bus->chg_allowed = true;
|
||||
bus->chg_voltage_target = bat->topping_voltage * n;
|
||||
bus->chg_voltage_min = bat->voltage_absolute_min * n;
|
||||
bus->chg_current_max = bat->charge_current_max;
|
||||
bus->chg_current_limit = bat->charge_current_max;
|
||||
|
||||
// negative sign for compensation of actual resistance
|
||||
bus->chg_droop_res = -bat->wire_resistance * n;
|
||||
@@ -476,10 +475,15 @@ void battery_init_dc_bus(DcBus *bus, BatConf *bat, unsigned int num_batteries)
|
||||
void charger_update_junction_bus(DcBus *junction, DcBus *bat, DcBus *load)
|
||||
{
|
||||
// relevant for DC/DC
|
||||
junction->chg_current_max = bat->chg_current_max - bat->current + load->current;
|
||||
junction->chg_current_limit = bat->chg_current_limit - bat->current + load->current;
|
||||
junction->chg_voltage_target = bat->chg_voltage_target;
|
||||
|
||||
// relevant for load output
|
||||
junction->dis_voltage_start = bat->dis_voltage_start;
|
||||
junction->dis_voltage_stop = bat->dis_voltage_stop;
|
||||
|
||||
// this is a bit tricky... in theory, we could add the available DC/DC current to keep the
|
||||
// load switched on as long as solar power is available, even if the battery is empty. This
|
||||
// needs a fast point-of-load (PoL) control of the DC/DC, which is not possible (yet).
|
||||
junction->dis_current_limit = bat->dis_current_limit - bat->current;
|
||||
}
|
||||
|
||||