Voltage replaced by DcBus ptr in PowerPort class
Preparation to separate current and voltage measurements and control parameters into DcBus and PowerPort classes. This will help to manage current from different sources (grid, solar) going towards one bus and control the battery voltage. It will also help to align multiple charge controllers in parallel, communicating via CAN bus.
This commit is contained in:
+29
-17
@@ -18,13 +18,14 @@ void load_init(LoadOutput *l)
|
||||
{
|
||||
l->port->init_load(14.6);
|
||||
l->port->pos_current_limit = 10;
|
||||
l->port->voltage = 14;
|
||||
l->port->bus->voltage = 14;
|
||||
l->junction_temperature = 25;
|
||||
}
|
||||
|
||||
void control_off_to_pgood_if_everything_fine()
|
||||
{
|
||||
PowerPort port = {};
|
||||
DcBus bus = {};
|
||||
PowerPort port(&bus);
|
||||
LoadOutput load(&port);
|
||||
load_init(&load);
|
||||
dev_stat.clear_error(ERR_ANY_ERROR);
|
||||
@@ -37,12 +38,13 @@ void control_off_to_pgood_if_everything_fine()
|
||||
|
||||
void control_pgood_to_off_overvoltage()
|
||||
{
|
||||
PowerPort port = {};
|
||||
DcBus bus = {};
|
||||
PowerPort port(&bus);
|
||||
LoadOutput load(&port);
|
||||
load_init(&load);
|
||||
load.state = LOAD_STATE_ON;
|
||||
dev_stat.clear_error(ERR_ANY_ERROR);
|
||||
port.voltage = port.sink_voltage_max + 0.6;
|
||||
port.bus->voltage = port.sink_voltage_max + 0.6;
|
||||
|
||||
// increase debounce counter to 1 before limit
|
||||
for (int i = 0; i < CONTROL_FREQUENCY; i++) {
|
||||
@@ -60,7 +62,8 @@ void control_pgood_to_off_overvoltage()
|
||||
|
||||
void control_pgood_to_off_overcurrent()
|
||||
{
|
||||
PowerPort port = {};
|
||||
DcBus bus = {};
|
||||
PowerPort port(&bus);
|
||||
LoadOutput load(&port);
|
||||
load_init(&load);
|
||||
port.current = LOAD_CURRENT_MAX * 1.9; // with factor 2 it is switched off immediately
|
||||
@@ -84,7 +87,8 @@ void control_pgood_to_off_overcurrent()
|
||||
|
||||
void control_pgood_to_off_voltage_dip()
|
||||
{
|
||||
PowerPort port = {};
|
||||
DcBus bus = {};
|
||||
PowerPort port(&bus);
|
||||
LoadOutput load(&port);
|
||||
load_init(&load);
|
||||
load.state = LOAD_STATE_ON;
|
||||
@@ -104,7 +108,8 @@ void control_pgood_to_off_voltage_dip()
|
||||
|
||||
void control_pgood_to_off_int_temp()
|
||||
{
|
||||
PowerPort port = {};
|
||||
DcBus bus = {};
|
||||
PowerPort port(&bus);
|
||||
LoadOutput load(&port);
|
||||
load_init(&load);
|
||||
load.state = LOAD_STATE_ON;
|
||||
@@ -121,7 +126,8 @@ void control_pgood_to_off_int_temp()
|
||||
|
||||
void control_pgood_to_off_bat_temp()
|
||||
{
|
||||
PowerPort port = {};
|
||||
DcBus bus = {};
|
||||
PowerPort port(&bus);
|
||||
LoadOutput load(&port);
|
||||
load_init(&load);
|
||||
|
||||
@@ -150,7 +156,8 @@ void control_pgood_to_off_bat_temp()
|
||||
|
||||
void control_pgood_to_off_low_soc()
|
||||
{
|
||||
PowerPort port = {};
|
||||
DcBus bus = {};
|
||||
PowerPort port(&bus);
|
||||
LoadOutput load(&port);
|
||||
load_init(&load);
|
||||
|
||||
@@ -168,7 +175,8 @@ void control_pgood_to_off_low_soc()
|
||||
|
||||
void control_pgood_to_off_if_enable_false()
|
||||
{
|
||||
PowerPort port = {};
|
||||
DcBus bus = {};
|
||||
PowerPort port(&bus);
|
||||
LoadOutput load(&port);
|
||||
load_init(&load);
|
||||
dev_stat.clear_error(ERR_ANY_ERROR);
|
||||
@@ -194,7 +202,8 @@ void control_pgood_to_off_if_enable_false()
|
||||
|
||||
void control_off_low_soc_to_on_after_delay()
|
||||
{
|
||||
PowerPort port = {};
|
||||
DcBus bus = {};
|
||||
PowerPort port(&bus);
|
||||
LoadOutput load(&port);
|
||||
load_init(&load);
|
||||
load.state = LOAD_STATE_OFF_LOW_SOC;
|
||||
@@ -218,7 +227,8 @@ void control_off_low_soc_to_on_after_delay()
|
||||
|
||||
void control_off_overcurrent_to_on_after_delay()
|
||||
{
|
||||
PowerPort port = {};
|
||||
DcBus bus = {};
|
||||
PowerPort port(&bus);
|
||||
LoadOutput load(&port);
|
||||
load_init(&load);
|
||||
load.state = LOAD_STATE_OFF_OVERCURRENT;
|
||||
@@ -240,12 +250,13 @@ void control_off_overcurrent_to_on_after_delay()
|
||||
|
||||
void control_off_overvoltage_to_on_at_lower_voltage()
|
||||
{
|
||||
PowerPort port = {};
|
||||
DcBus bus = {};
|
||||
PowerPort port(&bus);
|
||||
LoadOutput load(&port);
|
||||
load_init(&load);
|
||||
load.state = LOAD_STATE_OFF_OVERVOLTAGE;
|
||||
load.usb_state = LOAD_STATE_ON;
|
||||
port.voltage = port.sink_voltage_max + 0.1;
|
||||
port.bus->voltage = port.sink_voltage_max + 0.1;
|
||||
dev_stat.error_flags = ERR_LOAD_OVERVOLTAGE;
|
||||
|
||||
load.control();
|
||||
@@ -253,12 +264,12 @@ void control_off_overvoltage_to_on_at_lower_voltage()
|
||||
TEST_ASSERT_EQUAL(LOAD_STATE_OFF_OVERVOLTAGE, load.state);
|
||||
TEST_ASSERT_EQUAL(LOAD_STATE_ON, load.usb_state); // not affected by overvoltage
|
||||
|
||||
port.voltage = port.sink_voltage_max - 0.1; // test hysteresis
|
||||
port.bus->voltage = port.sink_voltage_max - 0.1; // test hysteresis
|
||||
load.control();
|
||||
TEST_ASSERT_EQUAL(ERR_LOAD_OVERVOLTAGE, dev_stat.error_flags);
|
||||
TEST_ASSERT_EQUAL(LOAD_STATE_OFF_OVERVOLTAGE, load.state);
|
||||
|
||||
port.voltage = port.sink_voltage_max - load.ov_hysteresis - 0.1;
|
||||
port.bus->voltage = port.sink_voltage_max - load.ov_hysteresis - 0.1;
|
||||
load.control();
|
||||
TEST_ASSERT_EQUAL(0, dev_stat.error_flags);
|
||||
TEST_ASSERT_EQUAL(LOAD_STATE_ON, load.state); // deprecated
|
||||
@@ -267,7 +278,8 @@ void control_off_overvoltage_to_on_at_lower_voltage()
|
||||
|
||||
void control_off_short_circuit_flag_reset()
|
||||
{
|
||||
PowerPort port = {};
|
||||
DcBus bus = {};
|
||||
PowerPort port(&bus);
|
||||
LoadOutput load(&port);
|
||||
load_init(&load);
|
||||
load.state = LOAD_STATE_OFF_SHORT_CIRCUIT;
|
||||
|
||||
Reference in New Issue
Block a user