Voltage replaced by DcBus ptr in PowerPort class
Preparation to separate current and voltage measurements and control parameters into DcBus and PowerPort classes. This will help to manage current from different sources (grid, solar) going towards one bus and control the battery voltage. It will also help to align multiple charge controllers in parallel, communicating via CAN bus.
This commit is contained in:
@@ -14,7 +14,7 @@
|
||||
|
||||
void reset_counters_at_start_of_day()
|
||||
{
|
||||
solar_terminal.voltage = bat_terminal.voltage - 1;
|
||||
solar_terminal.bus->voltage = bat_terminal.bus->voltage - 1;
|
||||
|
||||
dev_stat.day_counter = 0;
|
||||
|
||||
@@ -42,7 +42,7 @@ void reset_counters_at_start_of_day()
|
||||
TEST_ASSERT_EQUAL(0, dev_stat.day_counter);
|
||||
|
||||
// now solar power comes back
|
||||
solar_terminal.voltage = bat_terminal.voltage + 1;
|
||||
solar_terminal.bus->voltage = bat_terminal.bus->voltage + 1;
|
||||
dev_stat.update_energy();
|
||||
|
||||
// day counter should be increased and daily energy counters reset
|
||||
@@ -55,14 +55,14 @@ void reset_counters_at_start_of_day()
|
||||
|
||||
void dev_stat_new_solar_voltage_max()
|
||||
{
|
||||
solar_terminal.voltage = 40;
|
||||
solar_terminal.bus->voltage = 40;
|
||||
dev_stat.update_min_max_values();
|
||||
TEST_ASSERT_EQUAL(40, dev_stat.solar_voltage_max);
|
||||
}
|
||||
|
||||
void dev_stat_new_bat_voltage_max()
|
||||
{
|
||||
bat_terminal.voltage = 31;
|
||||
bat_terminal.bus->voltage = 31;
|
||||
dev_stat.update_min_max_values();
|
||||
TEST_ASSERT_EQUAL(31, dev_stat.battery_voltage_max);
|
||||
}
|
||||
|
||||